Great video Curtis!! Looking forward for next one , keep up the great work.
@robalexander7348 Жыл бұрын
That's a nice repair Curtis 👍 Au
@hinspect Жыл бұрын
I enjoyed the Video, thanks! I modified a couple of my adjustable wrenches that wouldn't open quite enough. Take out the setscrew and turn the thumbwheel until the movable jaw comes out, put it in a Vise then get a hacksaw and cut another slot in the jaw to get another turn on the thumbwheel. I could get them to open another 1/8 to 3/16 wider and it doesn't hurt the wrenches. Crescent, Xcelite and Diamond. Looking forward to your next Video! 👍🇺🇸
@jima3129 Жыл бұрын
You shoulda just bought a metric adjustable. 😂😂😂😂
@stevencossaboon3237 Жыл бұрын
Great job Curtis.
@harrydickson4575 Жыл бұрын
Another great job 👍👍
@HVACGUY Жыл бұрын
Thanks again!
@stephenbullock-yn3vh Жыл бұрын
Excellent fix curtis Riley is growing up fast.👍
@HVACGUY Жыл бұрын
Sure is!
@markcotter2355 Жыл бұрын
Your amazing at putting all those hats on and no help. Good job. Note I would recommend using wet rag or heat block blankets when you’re brazing next time and all the time. And get a little more feather in your torches flame, less oxygen.
@danobrien3109 Жыл бұрын
Nice save on the compression fitting Curtis . Pretty crappy that the new replacement coil doesn’t have a drain pan attached. 👍👍🇨🇦
@HomeOrchard Жыл бұрын
There is a Trane product made overseas that was designed to compete with lower cost contractor-grade units.
@1982deleterius Жыл бұрын
OxBox, uses LG compressor. I've had one for 2 years and have had 0 issues. Longevity i'm not so sure on.
@arodandjeter1 Жыл бұрын
@@1982deleteriusthat’s ameristar. But they’re the same thing. POS. But hopefully you have good luck with yours
@donnyjackson1908 Жыл бұрын
Built by Midea in China for Trane.
@MultiInKIEto Жыл бұрын
@@1982deleteriusbe careful with those LG Compressor even the Refrigerator Lines were Suite back in 2020 most of them were Junk Compressor how do I know I got some money back from Them..😅
@Austin23191 Жыл бұрын
It's made by Midea, a Chinese company. It's the same company that makes Bosch heat pumps
@robertmoore80465 ай бұрын
Hey Curtis I enjoy your videos. You may like a clear or tinted face shield while brazing from above inside those condensers. Thanks!
@search_eternal Жыл бұрын
That system looks just like Bosch stuff. Probably made in the same factory in China. Great job.
@jlr0221595 ай бұрын
I live in the central Indiana area, north of Indianapolis. I have a seven-year-old trane heat pump and the water has started dripping off the evaporator coil and down into the base of the heat pump. Not all of the water is dripping down the coil and into the drip pan along the edges… it is gripping straight from the A coil, straight downward. This is very frustrating! I have had multiple HVAC companies out here to look at it. One said that I need to replace my drip pan so I basically told them to get lost because that’s certainly not the problem here. Another company came out and replaced the drip pan drainage pipe and then said they are at a loss they don’t know what to do. So I am stuck! I have called trane corporate and given them my information and no one has gotten back to me yet. It’s very frustrating, I have a 10 year warranty on parts but nobody can tell me what’s really wrong here. Do I need a new A coil? At this point, I don’t really know. They repair man have checked the pressure and said that it’s correct so I don’t believe that low refrigerant is the issue. I’m at a loss and I’m frustrated.
@geronimome4153 Жыл бұрын
For a natural bug repellent try lemongrass,peppermint and tea tree oils. You can spray your arms or moisten a cloth and wear it around your wrist or neck.
@UncleEarlHeatingAirCondition Жыл бұрын
Thanks for sharing, picked up some tips!
@HVACGUY Жыл бұрын
Glad it was helpful!
@isairomero898 ай бұрын
i like your work, you just got a new subsciber.
@86AW11 Жыл бұрын
Quick question if anyone cares to answer. Two rooms on the sunset side of the house. Multiple HVAC companies have some out and said no issues. These rooms are consistently hotter in summer and cooler in winter. They are closest to the attic mounted air handler. Usually a three degree difference between these rooms and the rest of the house.
@jthonn Жыл бұрын
If I understand you right, it could be they are not as insulated? It only stands to reason also if they are smaller rooms, they usually will heat or cool off quicker than the rest. Try leaving the doors open to get a good circulation going and see if that helps. Also make sure you have an inch or so of space between the floor and the bottom of the doors. That way you have some circulation when the door is closed. Hope that helps
@86AW11 Жыл бұрын
@jthonn insulated the same as the rest of the house. Doors are usually open. One of two returns is in hallway between the rooms.
@wendelfears1027 Жыл бұрын
It's z du t issue. Being closer to unit. Means placement on supply plenum. If eacr room has it's own tap. Try and relocate the two taps. Check for dampers. Some installers close off the first few taps to allow more air for for longer lines.
@86AW11 Жыл бұрын
@wendelfears1027 No dampers, the airflow from the registers has been checked to be in spec. I asked about blower fan speed being too high, never got a good answer. I have two closed registers in a closet and storage room that I am thinking of relocating to these rooms.
@davidaustin9009 Жыл бұрын
Being the load side of the house..should have a higher r factor of insulation by at least 2or 3. Check the inner wall for insulation.occasionally spots get missed and that causes a big loss when cooling and heating. Considering heat load transfer thru walls.
@willflores671 Жыл бұрын
Curtis we gotta get you some new jeans brother!!!!
@juanarboleda Жыл бұрын
Hi Curtis, When you recover refrigerant from the evaporator with the condensing unit are you likely to also get ambient air from the evaporator leak? Thanks for answer
@jamesfitzsimmons381 Жыл бұрын
Also Curtis how long was the original coil installed?
@jthonn Жыл бұрын
Nice work as usual. I like your co-star.
@HVACGUY Жыл бұрын
Thank you very much!
@MultiInKIEto Жыл бұрын
Wait wait I got this one ..... NOTHING CAN'T STOP 🛑 A Trane except a Compressor or EVAP Coil and it gets even Harder to start the Trane!!!!!!
@MariosACandRefrigeration Жыл бұрын
you could check delta ,if you do not have 18 it needs a bigger piston,or you could have look at the #,thanks for sharing.
@rickr6908 Жыл бұрын
Nice job! Reily is getting big.
@nicolasmuniz9452 Жыл бұрын
Is that Tranes Yugo model, AmeriTrane.
@TheSimba86 Жыл бұрын
Those Tranes must be made by Norfolk Southern as often as they go off the rails
@549BR Жыл бұрын
This is what is called a play on words; very creative.
@KeithGoldsmith-kd7yw4 ай бұрын
Hey Curtis; where that tool list I heard about? Great job btw. Also, do you have a favorite mini split?
@williamcarothers8348 Жыл бұрын
Ameristar isn't from the Trane line. It's distributed by Ingersoll Rand which own Trane. It's just a cheaper option meant for rentals and hotels. Don't get me wrong, they are hot garbage. It's funny to see the outside box. Ameristar made in China. I sold Trane, Ameristar, & Mitsubishi mini splits for years at Lyon Conklin a subsidiary of Ferguson.
@lewiemcneely9143 Жыл бұрын
You caught it anyway and a mighty moderate co-star! Blessings 2 yall
@jamesfitzsimmons381 Жыл бұрын
Too bad they didn’t call you earlier in its life. Running with 0-5 SH for extended?time not good for it. Glad you caught the piston
@woodystokes1543 Жыл бұрын
Don’t see you measuring the inside wet bulb ? How do you know what the super heat should be 😊
@1decks Жыл бұрын
What company makes the best natural gas forced hot air furnace. Also the best central air conditioner? Thanks
@bymarkhvac64 Жыл бұрын
Carrier
@1decks Жыл бұрын
@@bymarkhvac64 thanks 😊
@ryanbrown5334 Жыл бұрын
The brand that is installed correctly!
@hvactech.florida5964 Жыл бұрын
It was originally called Ameristar. I’ll call them Ameri junk.
@Hvac-dude Жыл бұрын
I agree !!
@azcatfan3544 Жыл бұрын
I have two Ameristars. Obviously a different model. Both are still working great after 17 years. Did just have to replace the blower motor on one.
@franciscotejeda1461 Жыл бұрын
Excelent job Mr Curties
@kens.3729 Жыл бұрын
Often wondered 🤪 who can Afford a TRANE HVAC Unit ? The same people that buy a Cadillac Escalade ?
@bobbychaney8372 Жыл бұрын
If you use Emory cloth on the lines before you cut it you won't get anything in the lines
@549BR Жыл бұрын
Is Lt. Reilly a pointer; and what specific type. All I've ever had is hounds, so I'm just guessing. 😎
@cardsfan1590 Жыл бұрын
Weimaraner I think
@edwardgarza5104 Жыл бұрын
Oxbox? How old was the evaporator
@butlerstouchHVAC Жыл бұрын
great video tech, what hoses do you have?
@browntigerus Жыл бұрын
Just curious, why you chose not to use an uncased coil with TXV/TEV instead of this with piston?
@BrendanN941 Жыл бұрын
The old coil was a piston, the replacement coil came with a piston. Pretty self explanatory
@jthonn Жыл бұрын
Maybe it's just me, but it seems like it's getting harder to find coils uncased.
@UncleEarlHeatingAirCondition Жыл бұрын
Yes, it has gotten hard to find.
@adamrspears19814 ай бұрын
The new coil didn't come with a piston??
@mikemoseley8711 Жыл бұрын
Is that a Oxbox by Trane
@StephenOstrander-ij6mi Жыл бұрын
i love the swaging tools for the drill they are great
@Sctronic209 Жыл бұрын
No drain pan Unbelievable. I think I need to clean my vacuum gauge. I think I would of done a hot swap on that orifice.
@billlaporte8255 Жыл бұрын
Hi Riley
@jewellhirsch16945 ай бұрын
Hi Curtis, you got tricked by the old piston deal you always check the piston size to make sure that it’s not the same size if it’s not then you always use your old piston that you removed out of your old call into your new call just goes to standard reason, but it’s been designed that system has been designed with that particular with that particular system in it I guess you know that by now I’m just kind of pulling your leg. It happened to me before too so you say it’s all part of the text stuff signing out for 20 years retired now Tallahassee. Fred.
@jamesfitzsimmons381 Жыл бұрын
Nice work. What was with the original coil?
@HVACGUY Жыл бұрын
Leaking
@c21meister Жыл бұрын
Aww ye ol’ ox box
@brentrapson5892 Жыл бұрын
Those aren’t made by Trane btw. Made in China by Ingersoll Rand. While Ingersoll Rand owns Trane they brought this product with them before Trane
@wendelfears1027 Жыл бұрын
Mexico really. The land of no inspectors, IPA, or labor unions.
@kens.3729 Жыл бұрын
Does Schrader intentionally design Defects into their Valves so they have a Guaranteed Revenue Source ? 🤪 They are Tops as far as Failures go. 🤔👎
@rickdiego511 ай бұрын
It might not be a good habit to put your torch tip on the gas hose of your acetylene torch.
@eddiemasuch7 ай бұрын
Noticed that you were wasting short peaces of your silver soider weld the short piece on the copper and then weld the full rod on the short rod then continue to weld the short piece on the copper no waste of silver solder
@twincam82511 ай бұрын
Trane is making a lot of junk plastic air handlers i retired from HVAC seem like a lot of coil failures leaks.
@NewDestinationEng Жыл бұрын
Oh man I never like to pump down R410A... That's risky... I have seen way too many compressor explosions so I rather recovery it
@karellodewijks4971 Жыл бұрын
😊😊👍👍
8 ай бұрын
Coil swap on a tran😂
@TheDeafMechanic Жыл бұрын
Absolute garbage units. Trane dealer I worked for sold them for about 2 years and stopped. The heat pumps go through defrost boards and sensors like crazy. Units are trash and not worth a dime.
@jaycrypto-ns7vs Жыл бұрын
I've done work on those units. It's a trane but more like a bosch.
@Hvac-dude Жыл бұрын
Hi curtis !!!
@HVACGUY Жыл бұрын
What's up?
@Hvac-dude Жыл бұрын
@HVACGUY not much !!! I will be in a attic all next week
@HVACGUY Жыл бұрын
@@Hvac-dudebe careful
@Hvac-dude Жыл бұрын
@@HVACGUY I will I'm bring ice water and a cooler of Gatorade with me and fans
@Austin23191 Жыл бұрын
@Hvac-dude get a camel back and fill it with water
@davidaustin9009 Жыл бұрын
If you add Vitamin K with Lecithin to your diet.the mosquitoes and bugs will leave you alone😊
@chuckquinn8026 Жыл бұрын
Hard to believe Trane puts their name on this stuff 🤦🏻♂️ So much for fancy coated coils too… Have you tried using Milwaukee M12 tubing cutters?
@HVACGUY Жыл бұрын
Yes
@jima3129 Жыл бұрын
Ok, now, why did you not take the corner shield off first???? Just thought id ask. Lololol.
@tonyrhoton6613 Жыл бұрын
Went 2 local trane dealer and looked at those and thought nope
@StephenOstrander-ij6mi Жыл бұрын
yes they sure should have sent you a full assy
@BigJohnson1566 Жыл бұрын
What did HVAC techs do 50 years ago without all these fancy gauges, it’s like Chinese mathematics.
@VonM-m5f Жыл бұрын
If you caught it you caught it…wow.
@ares3914 Жыл бұрын
When checking at the condenser charge only with subcool. The superheat only has to be between 4-24°. If you check you auperheat inside then your superheat will be 10-30° different inside than outside. This a common mistake in residential refrigeration. So charge the condenser to its nameplate subcool and the check your superheat inside. 6 inches feom your valve. Then adjust your valve accordingly. In commercial most times you will not have a subcool to read so you charge theough superheat. Hope you learn