⭐ Other Helpful Videos: Top 5 Furnace Problems: kzbin.info/www/bejne/imWsiKeBrpJgjM0 Top 5 A/C Problems: kzbin.info/www/bejne/fYC7mJekh6drapI Furnace Sequence of Operation: kzbin.info/www/bejne/d4KnkICbma6eoqs Furnace Error Codes Explained: kzbin.info/www/bejne/gGm9lpqjabl2oq8 How to Read Furnace Wiring Diagram: kzbin.info/www/bejne/aH62lpd3oM6lp9k How to Read AC Wiring Diagram: kzbin.info/www/bejne/f17Wc2d9ftGVopY
@silentwackem6 ай бұрын
9
@robertcontreras88136 жыл бұрын
Im a hvac service tech for 15 years and i have to say i still go to ur videos if i get stuck on a problem u explain it very simple and easy
@WordofAdviceTV6 жыл бұрын
Thanks Robert! Means a lot coming from a veteran tech :) I will try not to disappoint with future videos :)
@cyanidex3 жыл бұрын
I've spent hours watching your videos, troubleshooting and cleaning my entire system, just to find out that my wife turned off the switch for the furnace because she didn't know what it was for. Make sure to start at the very beginning, folks! Even if you think the switch should be on... you just never know. :P
@masonoltman58913 жыл бұрын
Christmas Vacation anyone?! 😂
@abnormalryu87762 жыл бұрын
this happened to me for the condesor unit !
@jimmyngo71332 жыл бұрын
It is good to intall an outlet like my .Problem solved and never accident switch to off by someone else and safety also.
@edmatthews92352 жыл бұрын
Omg thats crazy. I may Put a marking on my Furnace on off switch dont touch. Mine is a large Red one so that helps but would not hurt.
@buleriastapas65432 ай бұрын
you made my week !
@jimt78512 ай бұрын
The number 1 go-to guy on KZbin when you have a furnace problem. Thanks Jay and very much appreciated.
@haroldpierre99463 жыл бұрын
I was in panic when my furnace blower motor was heating and stopped to work after 2 minutes running. With your very concise and helpful video, I was able to fix my issue with a new $5 Capacitor. Keep up the great work!
@TheDocalphabet6 ай бұрын
Our upstairs AC unit was making a loud buzzing noise and there were no cold blowing from our registers. Stopped power to the unit assessed the problem squirrel cage was hard to hand turn…pulled out to find motor bearings were burnt. Meanwhile an electrical storm rolled through our area last month during that event we decided to turn off the down stairs unit. Soon after the storm cleared went turned on the unit with no success. I did everything possible to get it going again. We called the HVAC tech and was quoted $1500 for a new motor…..ahhhhh what? After a few weeks of you tube videos I always came back to yours. My upstairs unit motor bearings were burnt so replaced the motor and capacitors for $179 and 3 hours of my time. Now to trouble shoot the downstairs unit repeated all the hacks on resetting to no avail. Back to your video……had the jumper by pass the board and VOILÀ….AC functional now I need to shop around for a new circuit board. Thank you so much. DIY Dude
@michaelfinnegan43018 ай бұрын
OUTSTANDING VIDEO! I'm no slouch, but I know nothing about HVAC. Friday night of Memorial Day weekend My 80 yo mother here to visit and the AC quit. It was 85 degrees in her room. I watched your video, I was able to diagnose the issue easily (it was the mother board) and was able to jump the mother board to keep the fan running and cool the house since everything else was working. One of the best how too videos I've ever watched. Simple, concise with great solutions. Thanks man! Gave you a thumbs up and subscribed.
@BenjaminMedlock4 жыл бұрын
I cannot say this enough, you sir saved me so much money. I did your multi meter checking and determined it was my control board. Thank you very much for making this content. I was able to do all the work my self for $100 and not waste money throwing parts at my system.
@80sGlamRocker12 жыл бұрын
You are a lifesaver and a fantastic teacher! I quickly diagnosed and removed my furnace blower, but the parts place near me said, Carrier does not make any parts or motors for my old system. It’s 34-35 years old, but until now, always held temperature and no sign of leaks. Got a portable to survive until we can look into a replacement heat pump system.
@malloryford95194 жыл бұрын
Dude. I’ve worked with my dad for his A/C & Heat business for a good chunk of my life & you explains this so well. In terms where everyone can understand. Keep it up!!
@Lolcowhunter0226 жыл бұрын
Ive been without heat for 2 days and have watched countless how to videos. Yours nailed it!! No more freezing!! Thank you!!!
@WordofAdviceTV6 жыл бұрын
Good to hear! :) Stay warm!
@erlpen20166 ай бұрын
All you have to do is what I did move to Dana point in California and you never have to pay another bill related to air conditioning….in fact you won’t need an ac unit….
@Lolcowhunter0225 ай бұрын
@@erlpen2016 🤣🤣
@brianwilliams698311 ай бұрын
Thanks. Even 5 years later this is a helpful video. My capacitor ended up being the problem. Your information saved me having to get a service call.
@JayGotIt237 ай бұрын
What issues was your ac showing?
@AdmiralPureBlood4 жыл бұрын
Man, I’m so glad I found your channel. Blower motor is turning on and it’s going to hit 95 today. I was lost yesterday watching others videos. Other channels speak as of every day men went to school for HVAC. Thank you brother i know now I can at least figure out the issue
@thepoliticalmechanic26914 жыл бұрын
This is probably one of the best how to videos I've seen in a long time there is a lack of nonsense commentary, a shill about some dumb sponsor and ear raping intro music and I absolutely love it
@LaudiumEnoch7776 жыл бұрын
You are VERY good at explaining how easy it is to troubleshoot EVERY part, therm, furn board, caps, condenser. I have seen a lot of youtube videos and you are by far the best I've seen. Bravo! People need to realize that things CAN be FIXED and a lot of the time its not that hard.
@WordofAdviceTV6 жыл бұрын
Thank you! :) Glad to hear you found my videos helpful! And I definitely agree! Many times the required fix is actually not that hard.
@abiynery6 жыл бұрын
Yes I have seen another one of his videos also. He is an excellent teacher.
@omarzambada85075 жыл бұрын
🍔🍔🍿
@robertwashington27595 жыл бұрын
Fantastic! You explain every step Safely, and in clear detail. Thank you!
@10acScottyP3 жыл бұрын
Agreed!!! Very easy to follow and understand. Fixed my dryer after following one of his videos just a couple weeks ago!!
@johnlone207 Жыл бұрын
I would like to say a huge THANK YOU!!! I, among others here, saved lots of money by fixing the furnace blower ourselves. The simple fix set me back about $12 (Capacitor), elbow grease, and about 5 min of my time. A task that otherwise would cost me hundreds, if I ended-up calling an HVAC service. Again, THANK YOU!!
@WordofAdviceTV Жыл бұрын
You're welcome!! Glad to hear the video helped and you were able to get it fixed! Have a wonderful summer!
@marks5265 жыл бұрын
Jay--9 months ago you really helped me with a problem with my blower and the control board on my Rheem Corsaire AC/furnace unit--you can see our whole dialogue below in the comments. However, the problem re-surfaced again this year in the same unit--namely i checked the air return below the filter and blower and sure enough it was completely full of cold water--luckily this time it hadn't shorted out the control board or fan but i figured i must have a condensate drain issue. There is another AC unit right next to it and i can see the condensate line draining water all day--but not on this unit. Both have similarly plumbed drain lines but unfortunately i cannot access the drain pan to inspect it. So here's what i did: 1. Cut the drain line close to the pan, attempted to vacuum the pan and then rejoined it with very tight plastic tubing over the outside of the PVC so i can see whether anything is coming out of the pan. 2. Vacuumed out and snaked (with a wire puller) the condensate line at the termination, but found no blockages or crud--the line is only about ten feet long in total 3. Installed a T before the P trap (there is a P trap in the line with an uncapped vent after the trap, but the trap was also clean) in order to make sure i could "prime" it as well as occasionally pour bleach into the trap. Now here's the odd thing: If i put the cap on the T before the trap, which is what i understand you're supposed to do, the condensate stops coming out of the drain and the drain pan overflows down the side of the blower, but if i take the cap off the T, the condensate starts running freely all the way out the drain, although i also lose cool air out that vent which i'm guessing means i have a positive pressure system. So what in the world is going on ? I've left the cap off the T and the condensate line is running fine now and there's no water in the return air compartment below the filter. Thoughts ?
@WordofAdviceTV5 жыл бұрын
Hey Mark! Sorry to hear about the AC troubles! From what you described, it sounds like the drain line gets pulled into a vacuum when the system is running. Having a T with a vent is actually a common procedure. If there is no T, sometimes I will simply drill a little hole on the top of the first elbow as it comes out from the drain pan. So I would just leave it the way you set it up. Sounds good to me :) and it's okay that there is air coming out of it. In fact, if there is no air coming out of it, then that will be a quick indicator for you that the drain line is plugged coming out of the coil.
@marks5265 жыл бұрын
@@WordofAdviceTV thanks for the quick response, Jay. I read so much stuff that said never to have an open vent before the P trap in a positive pressure system--but ultimately that's what works so i guess i need to have my physicist buddy explain why to me ! I also suppose i don't really need to prime the P trap either--i originally thought i had a negative pressure system and the P trap dried out and allowed air to be sucked into the drain--again, thanks and keep up the great videos
@timdelgado97103 ай бұрын
First year tech here this video was very informative and simple you didn’t confuse me like everyone else 😂
@mtthielsen83425 жыл бұрын
I love your videos, and wanted to add something that happened to me, I'm not an HVAC tech. My motor would not start, even after I heard the relay click on, so one would assume the start capacitor. This theory was also reinforced when I had to hand start the fan (not recommended if you don't know about this stuff), but it still had trouble starting and I realized the motor bushings were out of oil, and it couldn't overcome the initial friction to start, as it was hard to turn and the motor was very hot if you did get it to run. Anyway I saved 175 bucks on a new motor by taking it apart and re-oiling the felt pads on the two bushings in the blower motor. It would not be hard for some people to do if you are mechanically inclined. Some motors may have oil ports, if they do I would use them.
@kdpcorp3 жыл бұрын
Best repair video. Incredible instructions. You caught all the little things. Examples: Break off screws, remember to center fan wheel, tighten screw... Thanks for posting.
@smothukuri13 жыл бұрын
You saved few hundreds of $ , I did this by my self after ordering the parts. Thank you so much. Yes it took some time compared to a technician. You are amazing on explanation of details.
@geeex57834 жыл бұрын
I know nothing about furnaces, HVAC but I watched your video and read the comments from the pros below and just wanted to thank you for making a video that is very detailed and in language that I almost understand... Lol! Well at least I know what to ask my professional HVAC service guy!:)
@jb195113 ай бұрын
Thanks! I'm getting ready to do what you suggest here, but I wanted to tell you that you've already helped me fix my air handler and a/c unit 3 different times over the last 3 years!
@TimmyTurner5-l5z8 ай бұрын
NOT only a knowledgeable young man, but you are very honest and kind person. God bless you!!!
@emoshawn773 жыл бұрын
80 volts at the black wire from the board. Jumped it and the fan came on. Pulled the board and the back was burnt up and crispy. Great video! Liked & Subscribed.
@jaycarlton20105 жыл бұрын
My Central A/C went out here in Michigan's Summer 2019 heat. After discovering that my blower motor was humming, I followed your instruction and found the problem to be the Control Board. Guess what....this is the furnace's 4th control board in 16 years. It gets shorted out because of moisture dripping from the frozen evaporator coils above. Finally figuring out the problem. Half of the home's unused rooms all have their ducts closed. Add that to a neglected filter in the middle of a heat spell and the system will freeze. Got the replacement board from Amazon today and will swap it out...hopefully for the last time ever! Thanks for you awesome tips.
@WordofAdviceTV5 жыл бұрын
Glad to hear the videos helped you figure that out! Hopefully that is the last time! :) Thank you for commenting, stay cool!
@surfyogi4 жыл бұрын
@@WordofAdviceTV I realized the motor bushings were out of oil, and it couldn't overcome the initial friction to start, as it was hard to turn and the motor was very hot if you did get it to run. Anyway I saved 175 bucks on a new motor by taking it apart and re-oiling the felt pads on the two bushings in the blower motor. It would not be hard for some people to do if you are mechanically inclined. Some motors may have oil ports, if they do I would use them.
@bobvila43816 жыл бұрын
After 3 trips to the supply I was able to install a brand new motor and squirrel cage. Your video made my job about 1000% better then it would have been had I just went for it without watching.... Thanks, Subbed!
@prince2lof15 жыл бұрын
Thank you! You helped me to fix my A/C fan problem. The inside fan would not come on at all and the A/C unit outside did not come on either. When I turn the control to fan only the fan or blower did not come on. After 4 hours of troubleshooting in a hot attic, I found the control board the problem. After looking closer I found a 5 amp fuse on the board blown. Replace it and guess what. Cold air is now blowing. Might want to add that in your next video. Could possibly save someone 4 hours in the hot sauna. Still could not have done it without your help. I saved at least. 2 bills. Thanks again!
@WordofAdviceTV5 жыл бұрын
You're welcome! Thank you for coming back and sharing! I do talk about the 3 or 5 amp fuse in many of my other videos but I guess I didn't in this one. Sorry about that. Glad to hear you were able to get it fixed! Your efforts were not in vain :) Stay cool!
@normanmau13523 жыл бұрын
Thank you for the furnace videos. Based on your information like feeling for a hot motor, I saved labor cost (est $200) on the furnace motor replacement by replacing the motor myself. This task was my first getting into furnace motor using area. I had by pass certified Hvac Mechanic requirements by looking for local motor supply house as well known ones would not sell to me. I know the motors are available on line but I wanted talk someone locally. Anyway thanks again.
@losmoore33587 ай бұрын
My fan blower just went out after installing a new condensor fan motor. Thanks to your video u help me diagnose the problem. Yes motor is hot. Thank u.
@jonnelson79175 жыл бұрын
I’ve been through a lot of videos. Your channel is the only one that is helpful. I now have heat again. Keep up the good work.
@WordofAdviceTV5 жыл бұрын
That's what I love to hear! Good that you were able to get the furnace fixed! Thank you for leaving a comment, stay warm!!
@sonnyj97053 жыл бұрын
You stole my comment
@ProsperInHealth5 жыл бұрын
Thank you for donating your time to make this video. Because of you, I was able to diagnose my HVAC problem.
@WordofAdviceTV5 жыл бұрын
That's good to hear! Glad I could help!
@jimkerr43213 жыл бұрын
Loved your video. I was sure it was going to be the blower motor but using your tests I determined it was the blower control board and was able to source the part and install it myself. Thank you!
@garykoh2633 жыл бұрын
Your videos are great. I have not found a solution yet to my thermostat problem. I have hot wired the RH and W1 to bypass the Honeywell HZ322 damper control panel and Nest thermostats. I can get 24V + at the Nest thermostat and I tried hot wiring the RH and W at the thermostat but it does not call for heat. So any advise?
@jimkerr43213 жыл бұрын
@@garykoh263 Not my videos and I'm no expert but rather than messing with the thermostat wires, just test the wires he suggests.
@bobs52872 жыл бұрын
I signed in to KZbin just to like your video since you led me a bad board and now my family is cools again. Don't stop what your are doing!.
@joesapia97322 жыл бұрын
Appreciate all your how to videos make my life so much easier helping friends and family
@andrewokolovitch9913 Жыл бұрын
I was able to troubleshoot my A/C problem down to a bad control board in my furnace with the help of this video. Thanks for your help.
@mahmoudibnemir87047 ай бұрын
Your videos are great! I always learn a new way of doing something and you explain everything perfectly!
@Eddie_Munster9 ай бұрын
Wow great video. Just wanted to say thanks. Haven’t even tried it yet but you explained everything very clearly and thoroughly without adding too much. Saving this video for future reference as well
@beringseadc Жыл бұрын
I can't thank you enough for your time ,that truck with how and what to do just put heat back in our house 🎉,tested way you said its the mother board on ours 😢,once again thank you
@sethr32434 жыл бұрын
By far your videos are the most informative i've seen on the web. Thank you for your help.
@1957defrost4 жыл бұрын
So thankful for your channel. We have an American Standard air conditioning unit electric with natural gas heat. We have had to replace the squirrel cage at least 5 times. The last one taken off was only on about 5-6 months old. The blades were all rusty and loose when taken out. Now the new one is making the same noise...every time its the squirrel cage. So frustrated with this unit!
@MORC4 жыл бұрын
Thanks, you’ve helped me with two furnaces in two different houses. Both had blower motor issues. I was able to confirm this latest one with the “Hotwire” technique. I made a simple jumper wire with blade connectors and just plugged it in, switched the unit on with the door switch repressed and heard buuuuuuuuzzzzzzz. No spinning but it did get hot! Bingo bad blower motor. Now to replace it 😢 Thanks again!
@lawrencechavers117 Жыл бұрын
You’re a lifesaver! Best video on KZbin! Very informative!
@fritzrobfern81544 жыл бұрын
Thanks man i found your videos in hvac that very well good explanation. .im hvac tech for almost 8yrs..but im lucky evrytime im watching ur videos explanation especially in electrical parts.love u men..
@YaverEkemen4 ай бұрын
awesome video, after i replace the motor still wasnt turning on, i used this technique to bypass and motor turned on, now i know i need a new board
@zoecat8084 жыл бұрын
My blower motor stopped working may have been stuck on for a long time up to 30 days. I have a replacement control board but there are other problems to solve before I install the new board. Thank you for the video! The popping sounds freaked out my dog.
@Chris-pj1os2 жыл бұрын
I reallty appreciate your clear, concise videos. You're the man
@dennisrandall80403 жыл бұрын
I wish you were doing a general test as testing for resistance across the common and your different speeds. Checking the start and run windings, thing like that. You’ve basically explained how to trouble shoot your furnace and your furnace alone. A lot do t have a board. Just relays, transformers and so on. I wish mine was like yours. Make my life 1,000 times easier.
@gary98792 жыл бұрын
You are amazing! You explain how to do trouble shooting and make it look so easy. Can’t thank you enough. Turned out to be my board as it wasn’t sending power to the blower. You are BEST!
@amorales96132 жыл бұрын
What board are you referring to?
@gary98792 жыл бұрын
@@amorales9613 Control Board
@amorales96132 жыл бұрын
@@gary9879 thanks!
@peterlaval9454 жыл бұрын
Your explanation is easy to follow and understand. I learn a lot from you. Thank you!
@Lessenjr2 жыл бұрын
Fantastic video. Just diagnosed a bad blower motor and capacitor. Thanks!
@billstanis49016 жыл бұрын
Thanks for your videos. I was able to quickly troubleshoot my blower not working. The squirrel cage moved freely so I pulled the capacitor to test it only to realize that my meter doesn't go down to micro ferrets. I reinstalled the capacitor, re-energized the unit, and turned the thermostat up to 90. The exhaust blower started, the burner ignited as it should and when I heard the unit click to start the blower I just reached in and gave the squirrel cage a little assistance in turning and wala, pushing hot air once again. Amazon will have my new capacitor here tomorrow for $10.00. Now I just need to be a human termostat when my wife wants hot air. Well only for one night. :)
@WordofAdviceTV6 жыл бұрын
Nice :) Glad to hear you were able to get it figured out! Stay warm! ;) And good luck with being the thermostat! (By the way, if you want, you can set your thermostat fan setting to ON instead of AUTO and just let it run all the time so you don't have to push start it each time the furnace comes on)
@ltdblaster4 жыл бұрын
Thank you for your video! Using your video, I found that my control board needed replaced. I was able to wire the blower directly to power to get my A/C back up and running for a few days while I waited for the new part to ship.
@mingluo884 жыл бұрын
Jay, you are the best. Watched your video and it helped me diagnose the control board problem. Your tip also helped me to get by a few Chicago chilly winter days while the new board is in order. Thanks a lot.
@adibee886 жыл бұрын
I just discovered your channel yesterday because of my new AC problem. I have SUBSCRIBED and I look forward to learning about the heating cooling systems and fixing my problems with your videos! Great Job!!!
@PaulKokoszka6 күн бұрын
Thanks for this great video. Helped me troubleshoot and fix my problem. Luckily it was the capacitor this time. 😮💨
@frankinsensed80582 жыл бұрын
Great video for blower problem on Thanksgiving! This is a great channel!
@dalebowley3 ай бұрын
For me, it was the fan switch on the thermostat (on the wall). Flipped it to ON. Things worked. Flipped it back to AUTO and fans still ran as they should, and cut off when they should. YAY! I have heat again. My brother helped me through the troubleshooting. He's a tech for the USPS in Des Moines.
@monicaweiesnbach185525 күн бұрын
Did they continue to work? I put my fan on, it works, turn it on auto and it stays on and gets to temp then shuts off.. but when turning back on the furnace will light but the fan doesn’t auto turn back on…
@keithhoward86516 жыл бұрын
Really like the way you do your videos sure does help me a lot I’m still learning this stuff. Thanks for taking the time to explain each step and the tech tips. Keep them coming.
@ralzam23862 жыл бұрын
J. 👏🏼👏🏼😃👍🙏 thank you very much because you help me find the problem to my furnace and I just saved a few hundreds. Winter is around the corner and my kids are going to need heat soon. Thank you sir and keep up with the good videos. You just help a average Joe.
@mariamchacon70312 жыл бұрын
The best videos on KZbin! Do you have a video of tools? For example the best digital gauges, Bust torch set up, Best vacuum pump Best recovery machine etc…
@Salama_7 Жыл бұрын
Hi, I’m just a homeowner, I’m just curious why didn’t you check resistant on the blower motor? you are doing a very good job here🫡🫡🫡 Thanks ❤
@WordofAdviceTV Жыл бұрын
Thank you! In this case it is unnecessary. If the motor is getting power yet it does not come on, it's for sure a bad motor. No need for further investigation. In the field this method simply works better and faster for me so I rarely ohm out furnace blower motors.
@kumarbhatia65662 жыл бұрын
Amazing wealth of knowledge. Thank you for sharing. Fairly sure we have this fault after replacing a defective dual run cap, the compressor is now functional but zero air out of the registers but we do have cooling. Will check the run cap for the fan you referenced. Many thanks again.
@ps3moe314 Жыл бұрын
Thank you for sharing your knowledge with the world. Much appreciated. What should i do if the everything works except the blower needs to be manually spun to start? It runs perfectly after i hand spin it.
@WordofAdviceTV Жыл бұрын
You're welcome! Sorry to hear about the blower troubles! Either your capacitor is dead or that blower motor is on its way out.. If you have a multimeter, it would be nice to check the capacitor otherwise just start by replacing it. Hopefully you won't need to replace the motor.
@vincentcasolaro20594 жыл бұрын
Thank you for a no non-scenes instructional tutorial without childish headache music.
@billschady58945 жыл бұрын
bro your videos saved me hundreds of dollars
@WordofAdviceTV5 жыл бұрын
That's what I like to hear! :) Thank you for commenting!
@danyd492 Жыл бұрын
Because of you, I was able to learn and diagnose what was wrong. Thank you so much!!!!
@hyukmeister3 жыл бұрын
Your instructions are spot on and easy to follow & troubleshoot. Workaround tip is icing on the cake. Thanks!
@CharlesNolanArt2 жыл бұрын
It would appear to me that so many places just want the big money repair but how do I know the truth? By watching videos like yours and learning. Thank you!
@harkamagar2013 жыл бұрын
AWESOME VIDEOS. YOU EXPLAINED EVERY THING IN A SIMPLE WAY.BRAVO.
@PatCeeC10 ай бұрын
A lot of advice about these parts and their functions. Thank You😊
@BigAsDiecast4 жыл бұрын
You are absolutely amazing brother! God bless you for all that you do for the HVAC community. You are a great teacher. You have no idea how much I have learned from you. I wish there were more people like you in the world. If I may, I would like to ask you a question about meters. Is there a big difference between the meter you use and the UEI 389B?
@CRV1958 Жыл бұрын
Excellent Video. Very clear and thorough. Thank you
@surfyogi4 жыл бұрын
I really liked this comment, I will quote it, it's important: "I realized the motor bushings were out of oil, and it couldn't overcome the initial friction to start, as it was hard to turn and the motor was very hot if you did get it to run. Anyway I saved 175 bucks on a new motor by taking it apart and re-oiling the felt pads on the two bushings in the blower motor. It would not be hard for some people to do if you are mechanically inclined. Some motors may have oil ports, if they do I would use them."
@wademattice89792 жыл бұрын
Awesome videos. Well explained and had great camera work. Saved me thousands on repairs. keep up the great work.
@amyaimster77873 жыл бұрын
THANK YOU SO MUCH!!!! Your video was so helpful. We bypassed the control board and the blower motor fired right up. We have to replace the control board, but the AC is working for now and that is so wonderful because it is 90 degrees today! Thanks again!!
@Knarf22856 жыл бұрын
I wish that I had seen this video before commenting on your other one for "AC Unit Not Turning On - How to Fix It". In a nutshell, my blower works when set to the ON position, but does not work when set to AUTO. No part of my system has been changed since I purchased the house a year ago and all systems (heat and cooling) have worked flawlessly until two days ago.
@stephenwisely20 күн бұрын
Thanks! Running like a champ again!
@samuelkoehler1903 жыл бұрын
So thanks for helping me figuring out that my fan wasn't bad nor my capacitor wasn't the issue. But in my opinion the cutting of wires was not a good idea. By passing the controll board or putting the line with the splitter into the cool will NOT give you A/C!
@tyler56622 жыл бұрын
when you are actually physically showing what you're talking about it makes way more sense then just looking at a power point slide. this is an easier way to learn something in a few minutes then listening to lectures for hours
@PROJECT.LUKE.ONE.755 жыл бұрын
With your thermostat calling for either heat or cool (for cool, the outside unit should be running), thd G wire should then turn on the blower motor at the furnace. If it's not, check the motor for voltage. To check for power (voltage), start by checking where your fan wires go into the control board. The black wire is normally high stage, which goes to cooling; heat is normally low stage, which goes to heating. Depending on which AC season your testing for, you will pull that wire off. Next, find where your common wire is coming from the motor (usually labeled circ. or circulator) and pull that wire off the control board as well. Place one lead on each spade that you've pulled a wire from. There should be a 120v present. If you have 0 volts when the fan should be on, then the problem is a defective control board. If you do have 120v present, and the fan isn't coming on, then the blower motor is bad. To test without a meter, find the wire for line voltage coming into the control board usually coming from the door switch) disconnect it, and depending on which AC season your testing for, pull off the high or low stage wire and bypass the control board by connecting the two wires together. If the blower comes on, the control board is bad. If it doesn't come on, the blower motor is bad. To temporarily get by with cooling or heating until the board is installed, you can connect the two wires disconnected wires to a spade splitter (bending the split) and connect the other end into the line voltage on the control board. This will send power directly to the motor through the power switch, bypassing the control board.
@rruizproductions4 жыл бұрын
Will the blower motor run continuously during bypass?
@michaelmaison55923 жыл бұрын
Levi you're great!
@billcampos33003 ай бұрын
This guy knows what he’s doing.
@longracing254 жыл бұрын
Love your vids, thank you. I have typical issue. Furnace comes on, blower motor hums and heats up...doesnt spin SOME times. Start manually...it will get going. I started with cheapest, capacitor. About same results, worked for a day maybe. If a motor is bad, wouldnt it not work at all? Obviously its getting power, new capacitor should be giving kick...would a failing motor work "some" or with a manually bump? Blower fan spins free, no binding also.
@nathanielreichert4638 Жыл бұрын
Yeah I just bought a house and did not check the filter, which was really nasty. Once the fan stopped blowing completely (but the furnace was still getting hot) I finally looked up your tutorials. I switched out the filter but the motor was scalding hot. The fan still spins fairly smoothly. I have it turned off now, and when everything cools down in a couple hours I will try to turn it on and see what happens, but I will probably need a technician.
@pbr2424 Жыл бұрын
You should be able to burn the house down.
@nj-bz8pv3 жыл бұрын
Thanks man! Very useful. My family’s teeth is chattering waiting for a new board to show up.
@f.osborn15792 жыл бұрын
...it started...idk why...I watched and performed up to hot motor and fan rotation by hand and it worked...I don’t know why, but it is now working. Must be the Gregorian chant I also did...
@paulylyus13 жыл бұрын
this was exactly what I needed. very well explained. thank you.
@fernandodiaz465 жыл бұрын
Diagnosed blower and found control board wasn’t sending power. Excellent video
@WordofAdviceTV5 жыл бұрын
Thank you! Glad you were able to find the problem!
@surfyogi4 жыл бұрын
What if it DOES send power, but the motor is old?! "I realized the motor bushings were out of oil, and it couldn't overcome the initial friction to start, as it was hard to turn and the motor was very hot if you did get it to run. Anyway I saved 175 bucks on a new motor by taking it apart and re-oiling the felt pads on the two bushings in the blower motor. It would not be hard for some people to do if you are mechanically inclined. Some motors may have oil ports, if they do I would use them."
@phillipsalois24275 жыл бұрын
Great video! Was able to figure out my problem was the capacitor. Replaced that and ac blower is now working! Thanks!
@dannyscott23508 ай бұрын
I have just de-iced my hvac and not getting air coming from my wall intakes. When I take the front panel off, and run the AC, I was getting good circulation through my air ducts. When I put that cover back on, I get very little and strong suction on the panel. Before this I found the old filter either sucked up from the bottom or stuck in there. I pulled it out and ran again to see if air came through the ducts (just purchased this home). I did de-ice the coils as I thought that this old gross filter probably caused the build up and the blower (above all the coils) would produce good air flow again. Wasn’t the case. Now what I notice is when I try to run the fan with heat/cool off, it doesn’t turn on. I deiced with heat gun and wondering if there are internal components that may still be compromising air to flow from the bottom intake to the top
@braydonfroese2 жыл бұрын
I'm so very happy you did get your voltage pen. It's a very nice voltage pen
@elbo530 Жыл бұрын
Great job on this video my friend!
@MKTGJRF2 жыл бұрын
Blower ran fine and smooth when tied directly to power, bought new capacitor before checking... Blue to hot and white to neutral. Thanks
@marks5266 жыл бұрын
Jay--very helpful video--my blower motor wasn't coming on and when i opened up the air handler compartment i found water up all the way to the filter ! Apparently drain was either clogged or p-trap was dry and wouldn't let it drain. Since water had been running down the side of the blower motor i wanted to make sure it wasn't shorted out etc so i followed your procedure. However, what i discovered was the there was not 120V coming out of the control board. Just to further confirm i followed your hotwire procedure and the blower motor immediately came on (relief !)--but when it came on water started running down the side of it again even though the drain pan was dry--so maybe water in the squirrel cage ? In any event things got weirder when i shut the power off (i have to unplug--there's no switch) and hooked the leads back into the control board--when i plugged the power cord back in the 15A buss fuse next to the plug in outlet immediately blew. I thought maybe the water had shorted the motor so i waited until the motor was dry and re-ran the hotwire test and the blower came on just fine (again relief !)--but when i unplugged, put the leads back in the control board and plugged in again my new 15A buss fuse blew immediately again. So now i don't know what's causing that--can a bad control board cause a short like that? And if so, why hadn't it shorted out the fuse in the first place? (ie the fuse was ok before i started all of the above). or is it possible there's a new issue ? Thanks in advance for any help
@WordofAdviceTV6 жыл бұрын
Hey Mark! Thank you for taking the time to tell the whole story and not just the last part :) Yes, it is possible that the control board is bad. Also, do you know for sure that you are plugging those wires back into the right spot? Which wire did you use to do the hot-wire and which terminal/s did you pull it off of and now putting it back on to? About the blower motor housing. I bet there was just some water on the bottom of the housing. In that case you can let it just dry out with time or take out the blower assembly and tip it over to drain it out. It's possible that the water leak took out the control board or damaged something else.
@marks5266 жыл бұрын
@@WordofAdviceTV thanks for the quick response, Jay. The wires i took off and jumped together were the black wire coming from the door switch--it went into the "Line" terminal on the control board & the blue wire on the "Cool" terminal going from the board to the motor--i'm pretty sure i plugged them back into the right terminals but i'll check to see if i accidentally switched them around. What worries me is that all that water (50 gallons +) collected in the air return compartment (fortunately this unit is outside the house here in AZ) but no condensate went into the secondary drain line to trip the float switch--it was dry as a bone--made me wonder if my drain pan is cracked but unfortunately on this Rheem unit there is no way to access the drain pan without cutting the coil casing. What a crappy design ! Is it possible that if i had a dry P-trap there would be so much air being sucked back into the drain pan that it would also prevent drainage to the secondary line, given their proximity to each other ? i went ahead and ordered a new control board--hopefully that's where the short is, although i didn't see any sign that water touched it. Will let you know in a week or so.
@marks5266 жыл бұрын
@@WordofAdviceTV OK Jay--now i feel like a bonehead--you hit the nail on the head with the short--i didn't switch the wires around but instead i plugged the black wire from the door switch into an open "neutral" terminal creating the aforementioned fireworks--yeesh. At least the fuse protected the blower motor--i hotwired again and it works fine--but i still can't activate the fan at the thermostat. Going back, since i originally didn't measure any voltage at the output terminals of the board i am replacing the board and crossing my fingers. Thanks again for your help--you ever done any dumb thing like that ?
@WordofAdviceTV6 жыл бұрын
Yikes, so a direct short is what it was. Glad to hear you figured it out though! There is a good chance that it is indeed the board that is bad. And yes, of course I had my share of blunders like that too :) one time I put in a hi-limit that I had to break a little tab off of to make it into 24v limit instead of a 120v... And I forgot to break that little tab. I fried the thermostat, the limit, the control board, and the transformer all in one go. Only did that mistake once.
@marks5266 жыл бұрын
@@WordofAdviceTV I remember my Dad telling me that "experience" is what you get immediately after you needed it :) The control board arrives next Wed so will let you know if that was it. I would never have thought of doing any of this myself without your assistance
@paulvanevenhoven5714 жыл бұрын
Your videos are great and helped me narrow down my problem. But I still don't have my answer. My blower motor does not turn on. (The inducer motor does run) I believe the root of my problem was a dirty filter, which I believe has caused my unknown issue. I did install a new filter. I replaced the limit switch (not the issue). The capacitor was tested and is good. I did jump the blower motor by using a jumper wire between the G & R terminals. When I do this the fan spins for about 1/2 second, but that is all. (This tells me that my control board is good I think). My blower motor spins freely when I spin with my fingers and the backside of the motor is not hot at all after sending signal to heat furnace for a few minutes. Now I'm stumped. What else should I check? Everything seems pretty clean and my unit looks just like the one you use in many of your videos. Any advice would be greatly appreciated. My wife tested positive for COVID and it's hard to get a professional to come to our house. Thank you!
@madelinerivera45644 жыл бұрын
You are awesome. Thanks to you we didn’t have to call anybody.👏🙏🏼
@sunshine-qr5bb3 жыл бұрын
Thanks for sharing your knowledge with us . It helped me out a great deal.
@UNITED20091004 жыл бұрын
Do they allow gas pipe unions inside the cabinets where you are???????
@meTimetraveler Жыл бұрын
it's quite possible the motor start capacitor is fully charged 1. you can get a real jolt 2, if you connect the capacitor at this state to your meter, the meter will be fried. You should try and discharge the capacitor before anything else. Touching an insulated handle screw driver to the bare metal contacts will do this BUT it is really bad for the capacitor to discharge this fast. you should use something like a 5k 5 watt resistor.
@whomenoyou101013 жыл бұрын
you make the best videos. Super clear and easy to understand, you cover all possibilities which is AMAZING...one question i have is, is it ok to bypass the control board for long time? i have a issue where my outside fan kick in and the blower motor for inside stops (vice versa as well)...so im thinking to try and bypass the control board.