This is a step by step on how to run electrical 230/115 volts AC to a mini split. Includes how to run electrical to a mini split and connect it to a panel, types of ways to wire a mini split and connecting to a disconnect and breaker.
Amazon Links to Products in Video
AC Disconnect: amzn.to/3UMpYtU
Liquid Tight Power Whip: amzn.to/3uE7m4A
PVC Conduit: amzn.to/3SGTXAV
PVC Conduit Pipe Fitting: amzn.to/3SCGJ80
Liquid Tight Conduit: amzn.to/3OQV6EN
KZbin Video Installing a Mini Split
• How To Install WYS Ser...
Always follow the codes in your local area for electrical.
Main Options to Run Electrical Wiring to a Mini Split.
PVC Conduit
Metal Conduit
Liquid Tight
Run Wires through the Building
By using this information user assumes all risk of use.

Пікірлер: 71
@HVAC_Mechanic
@HVAC_Mechanic 2 ай бұрын
UPDATE: After this video I swap out the beaker for a Square D breaker to match the panel.
@avsararas7969
@avsararas7969 Ай бұрын
Panel matching breaker brand is just a revenue-making restriction. Siemens is actually a better breaker than Square D, no seize ups and hiccups.
@jcchan08
@jcchan08 5 күн бұрын
@@avsararas7969 they have gotten alot better. The 1st gen AFCI breakers were tripping from 5G interference
@soupp187
@soupp187 3 күн бұрын
Great video! Easy to follow. I was just quoted $2,500 for this, and that didn’t include digging.
@theblackshepard4441
@theblackshepard4441 4 ай бұрын
Mann this vid straight to point good suggestions no stupid music good point of views vid save me so much money
@Tim011277
@Tim011277 6 ай бұрын
A well done video. Only thing I would suggest is to ether have run the "hot" legs as red and black, or at the very least, marked the white wires with black marker to denote that they are not a grounding (neutral) connector, but are used as a hot. Again, if this was me, I would have picked up Red / Black / green from the supply store. But still, a very good video.
@fernandorivera7155
@fernandorivera7155 12 күн бұрын
You seem to know about electrical. I am installing a 2-zone unit, and the 240-volt connector has a place for re 11:58 d, and black, and the 3rd one is ground. Is the 3rd one for connecting the neutral white? The instructions are pretty bad. Thanks
@smsjr36
@smsjr36 3 ай бұрын
Thank you ! One of the best videos of mini split electrical hook up. No nonsense and very informative.
@nickwithad
@nickwithad 2 ай бұрын
Thank you for this. Made my install that much easier.
@angelarciniega7294
@angelarciniega7294 4 ай бұрын
The best video. Ever You are so profesional and you straight to the point ..thank you very much ..
@frankjo-md3dm
@frankjo-md3dm 4 ай бұрын
great informative video, one suggestion for you to replace that breaker with Square D breaker.
@henrirt8991
@henrirt8991 Ай бұрын
You should have used a red and black wires on a 220v circuit, not white.
@avsararas7969
@avsararas7969 Ай бұрын
Mark the white with red tape and all fine.
@gregwilcox1696
@gregwilcox1696 5 ай бұрын
Great video
@johnjones9329
@johnjones9329 24 күн бұрын
Great video, thank you!
@bartman22x1
@bartman22x1 Ай бұрын
Thank you for this video
@dangerdoberman
@dangerdoberman Ай бұрын
Whoa. That's really great.
@JereB698
@JereB698 6 ай бұрын
I installed a 9000 BTU unit and it use a 15 amp breaker and 14 Gauge wire. Thanks for the video very helpful
@andrehmoti1411
@andrehmoti1411 5 ай бұрын
Hi And how is work? Is any problem with wire 14 Gauge and 15 amp to connect to 9000 btu ? Thanks
@JereB698
@JereB698 5 ай бұрын
@@andrehmoti1411 My unit is rated for 15 AMP breaker 14 Gauge wire, so it works good for me
@andrehmoti1411
@andrehmoti1411 4 ай бұрын
@@JereB698 how many volt 230v or 115v ? Thanks
@JereB698
@JereB698 4 ай бұрын
@@andrehmoti1411 230 volt
@RichardPippin-ju2sg
@RichardPippin-ju2sg Күн бұрын
Thank you for the video. I am connecting mine this week. I have installed my steel pipe, but I used tight corners. You used a curved pipe for making turns. Is this code?
@HVAC_Mechanic
@HVAC_Mechanic Күн бұрын
Outside metal conduit corners are usually bought and attached. Bending the corners is usually only done during new construction where they can fit into the wall. There are good KZbin videos on installing metal conduit. Be sure to check your local codes since they can vary.
@rpfeiff
@rpfeiff Ай бұрын
You should either use a red wire, not white, or at least mark the white wire with red tape.
@shafi10a
@shafi10a Ай бұрын
So is there no neutral wire needed ?
@TrungTheMaker
@TrungTheMaker 2 күн бұрын
For your disconnect did you need to add fuses to it?
@HVAC_Mechanic
@HVAC_Mechanic 2 күн бұрын
I don't think this one was fused, but some disconnects are fused, while most are not. If it is fused, then yes, it will need fuses.
@msix79
@msix79 3 ай бұрын
What fitting are you using for your 1,2 & 3 wire from the inside unit to outside unit? Looks like a sealtight?
@InvisibleCitizen
@InvisibleCitizen Ай бұрын
Why are these 240 volt mini splits not wired the same as a washer dryer combo which are four wire? There is no bonding? The green jumper wire would be removed so the bare ground wire could be used to bond the unit. A shock hazard similar to a washer dryer combo?
@spenceratkins
@spenceratkins 4 ай бұрын
I bought a pioneer 12k btu but it’s a 115v 60Hz 1Ph with a max fuse of 25A. This means I need to run a 10g wire right? And does my breaker need to be single phase or double?
@HVAC_Mechanic
@HVAC_Mechanic 4 ай бұрын
10-gauge wire will work on a 25-amp circuit with no issues; just use the correct breaker size (Some 12-gauge wire is also rated for 25-amps but be sure to check its specifications). In the USA 120/240 Vac is single-phase.
@allisonhoon2801
@allisonhoon2801 Ай бұрын
My electrical panel is quite a ways away from where my mini split is going - complete opposite side of the house. I have an existing outlet on the INSIDE of the wall - can I re-purpose that and put a breaker/disconnect off of that (no longer to be used on the inside) to the outside or do I need to run a dedicated line? Dealing with a 115v unit.
@HVAC_Mechanic
@HVAC_Mechanic Ай бұрын
It will depend on whether the wire size is rated for the amps. 115-volt units pull more amps, often roughly 20 amps or more (but be sure to check). Indoor wiring can be 14-gauge or 12-gauge. 14-gauge wire is rated for up to 15 Amps, and 12-gauge wire is rated for 20 amps. While it is possible, it is likely best to have an electrician examine it.
@leonardpowell1444
@leonardpowell1444 Ай бұрын
@@HVAC_Mechanic I believe it requires a dedicated circuit, and that outlet is probably required to remain there, and it likely also has other outlets or devices on that same circuit, so such a conversion is not suitable.
@user-hc9zm3lu4p
@user-hc9zm3lu4p 3 ай бұрын
Im going to install a 12,000 btu Traiden mini split I' d like to know if I can place the external unit on top of the roof....... It will be at about 3 ft. Above the internal unit level
@HVAC_Mechanic
@HVAC_Mechanic 3 ай бұрын
Yes, they can be set on the roof. Three feet from the unit, the line set will likely need to be cut and re-flared, but you can leave it rolled up.
@user-hc9zm3lu4p
@user-hc9zm3lu4p 2 ай бұрын
@@HVAC_Mechanic exelente, thank you
@TheHouseofChameleons
@TheHouseofChameleons 4 ай бұрын
I have an existing fuse disconnect 3 ton AC with a 40 amp breaker in the main panel. Can I add a 1 ton minisplit by replacing the fuse disconnect into 2 breaker subpanel of 30 amp and 20 amp subpanel?
@HVAC_Mechanic
@HVAC_Mechanic 4 ай бұрын
The wire and breaker all need the rated size. If the wire is rated for 50 amps (6-Gauge) and the 3-Ton Ac unit rated for 30 Amps than it can be done otherwise a new breaker and wiring will be needed.
@aaatoycollection
@aaatoycollection 2 ай бұрын
Can I use a 12-2 wire for a 3 zone , 27,000 btu pioneer mini split.
@ziggyd3114
@ziggyd3114 Ай бұрын
Look at the name plate on the unit. The information you need will be listed there
@aychkaykay88
@aychkaykay88 2 ай бұрын
do you need a disconnect box if your main panel is 4 feet from your condenser unit? I hoping to remove the disconnect box and run the L1 & L2 wires directly to the 20amp breaker in the panel. is that not safe?
@HVAC_Mechanic
@HVAC_Mechanic 2 ай бұрын
It depends on the location and is required by code, which I think is all USA jurisdictions, but it is possible it is not required in some areas. You will need to check local codes to know for sure. It likely is safe, but if an inspection is needed, such as for a new installation or selling the home, it will likely not pass. It is best to talk to a local electrician and see what they say.
@leonardpowell1444
@leonardpowell1444 Ай бұрын
You need a means of disconnect within 6 feet. Sounds like your breaker panel within 4 feet will suffice. Be sure to clearly label the breakers. Black sharpie pen is not a suitable labeling device.
@juniormedina9282
@juniormedina9282 2 ай бұрын
Can I use a 60amp disconnect with a 30amp fuses or 30amp disconnect non fuse
@mikafoxx2717
@mikafoxx2717 Ай бұрын
Just make sure the fuses and breaker are right for your unit, and that the disconnect is rated for enough power.
@joshuachoun7169
@joshuachoun7169 4 ай бұрын
I have a 24k unit and it calls for 220v. What breaker amp would I need to make it 220?
@HVAC_Mechanic
@HVAC_Mechanic 4 ай бұрын
Breaker size can vary depending on how efficient the unit is and depends on the unit-rated AMPs. The rated AMPs will be in the manual or the unit's nameplate.
@razorog3283
@razorog3283 Ай бұрын
i dont think i could be applied to 115 systems because some of them the power is going directly into the indoor unit.
@gradyogrady
@gradyogrady 3 ай бұрын
My 9k unit is 120 V. Can you please tell me how to wire the disconnect?
@HVAC_Mechanic
@HVAC_Mechanic 3 ай бұрын
It is best to watch a video as there are a lot of them for wiring a disconnect, but a disconnect is just a way to break the wire connection quickly. Basically, each leg (wire) goes to one port and the same on the other side. Some electricians tie the common (white) wires together and just break the connection with the Hot (black) wire.
@Trainman0401
@Trainman0401 4 ай бұрын
Help….does the circuit need to be GFCI? Thanks!
@HVAC_Mechanic
@HVAC_Mechanic 4 ай бұрын
No, a GFCI is not used. Just a disconnect and the correct wire and breaker size.
@reidsmith3002
@reidsmith3002 2 ай бұрын
What’s wrong with using pvc? Haven’t you seen it used above ground on every power pole pretty much anywhere
@HVAC_Mechanic
@HVAC_Mechanic 2 ай бұрын
If the PVC is run sideways, it will sag, which is a bad look. In the climate where I live, the sun turns it black and gives it a burnt look after 2-3 years. It can be used, but it doesn't look good after a few years, at least where I live.
@leonardpowell1444
@leonardpowell1444 Ай бұрын
I don't know if it's allowed, but painting it with latex paint will help preserve it.
@JoseLOPEZ-fk5gc
@JoseLOPEZ-fk5gc 2 ай бұрын
How much would an electrician usually charge for this type of job?
@HVAC_Mechanic
@HVAC_Mechanic 2 ай бұрын
Where I live, it is roughly $300-$800. It will depend on where the electrical box is and where the unit is set; a long hard run will cost more. The only way to know the cost for sure is to get quotes.
@JoseLOPEZ-fk5gc
@JoseLOPEZ-fk5gc 2 ай бұрын
Thank you sir and great video
@kevintroyharrington
@kevintroyharrington Ай бұрын
My manual says nothing about breaker or wire size.
@HVAC_Mechanic
@HVAC_Mechanic Ай бұрын
Look for the Max Amps the unit uses, and that can be matched to the breaker and wire size.
@leonardpowell1444
@leonardpowell1444 Ай бұрын
Right. Go to a chart on the web for recommended wire sizes based on electrical load and length of wire.
@CharliesPurpose
@CharliesPurpose 5 сағат бұрын
I'd just use 8
@jcchan08
@jcchan08 2 ай бұрын
If you get that inspected that Siemens breaker in a Schneider Sq D panel and White on L1 will get flagged.
@HVAC_Mechanic
@HVAC_Mechanic 2 ай бұрын
You are correct it was what I had on hand that day. I was told the breaker was rated to work in the panel, but I swapped it out a few days later so there would be no issues. I also used a marker and some tape to mark the wire.
@jcchan08
@jcchan08 2 ай бұрын
@@HVAC_Mechanic I’ve subscribed, I think you did a really nice job in this video.
@gametime5726
@gametime5726 2 ай бұрын
Great video
@pontetrucho-oz7it
@pontetrucho-oz7it 3 ай бұрын
I have a 12k btu unit 110v, can I plug this into a regular plug?
@HVAC_Mechanic
@HVAC_Mechanic 3 ай бұрын
No, that's not recommended, but it would depend on the amps the unit uses. A standard home outlet capacity is 15-20 amp so the units rated amp draw would need to be below that. It also would need all other outlets and lights on the circuit to be blocked off. It is best to run its own dedicated wiring and breaker.
@leonardpowell1444
@leonardpowell1444 Ай бұрын
No. Dedicated circuit required. Can't repurpose an old one.
Complete DIY Mini Split Installation | New Mr Cool 4th Gen Unit
18:43
Everyday Home Repairs
Рет қаралды 401 М.
Don't make this electrical mistake #Shorts
0:58
Backyard Maine
Рет қаралды 3,4 МЛН
Мы сделали гигантские сухарики!  #большаяеда
00:44
Challenge matching picture with Alfredo Larin family! 😁
00:21
BigSchool
Рет қаралды 43 МЛН
Blue Food VS Red Food Emoji Mukbang
00:33
MOOMOO STUDIO [무무 스튜디오]
Рет қаралды 9 МЛН
10 Common Mistakes DIYers Make In Circuit Breaker Boxes
13:55
LRN2DIY
Рет қаралды 2,4 МЛН
Wiring a Mini Split System, Step by Step!
11:29
AC Service Tech LLC
Рет қаралды 679 М.
How To Install An AC disconnect - ALL WIRING!
14:53
The Excellent Laborer
Рет қаралды 104 М.
Electrical Wiring Basics
23:40
BrettleyBuilt
Рет қаралды 2,8 МЛН
#1 Reason Why DUCTLESS Units Fail | How I Fix It...
13:59
Quality HVACR
Рет қаралды 811 М.
Mini Split - 3 Things I Wish I Knew Before Installing
8:44
LRN2DIY
Рет қаралды 1,2 МЛН
The Top 7 Things AC Companies Don't Want You To Know How To Do!
17:29
Installing A Mini Split in 60 Seconds
1:00
The Handyman
Рет қаралды 1 МЛН
Мы сделали гигантские сухарики!  #большаяеда
00:44