Roll Out Switch Diagnosis

  Рет қаралды 48,170

HVAC Know It All

HVAC Know It All

Күн бұрын

On this Saturday call I respond to a no heat where I had to perform a roll out switch diagnosis. The roll out switch tripped and I had to figure out why.
In this video we discuss how to check evaporator superheat using testo smart probes in a walk-in cooler. Checking superheat at each evaporator on a multi evaporator system is important to system performance.
Save 8% on your purchase www.trutechtoo... with promo code knowitall
Check out www.hirago.com/
Visit HVAC Know It All on social media Facebook / hvacknowitall
Instagram / hvacknowitall LinkedIn / gary-mccr. .
Listen to the HVAC Know It All Podcast anchor.fm/hvac...
Visit www.hvacknowit... for articles, and tips.

Пікірлер: 52
@hvacslayer2929
@hvacslayer2929 4 жыл бұрын
Lol damn that unit with its own gazebo those stairs gnarly 🤘🏻
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Hell yah! Lol
@actechformallyyomama746
@actechformallyyomama746 4 жыл бұрын
I think you got it right. Had the same problem with Carrier gas pack. Had 4” at the manifold. It doesn’t take much when it’s a small unit. Stay safe
@diplenski
@diplenski 4 жыл бұрын
i would have suggested checking the heat exchanger, also amp draw of inducer, and check exhaust for possible/partial blockage
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
I did check the heat exchanger, you should watch the entire 😆😆. The unit has been running call back free.
@diplenski
@diplenski 4 жыл бұрын
@@HVACKnowItAll my bad i missed it first time, not trying bust balls. also good to check between cells closest to burners, if there are rivets/rings will be the first place to crack. as old as it is and heat stressed as it looks id be surprised if there wasnt at least a small crack. gaspacks are especially prone to hx failure bc the evap is before the hx causing condensation and rot
@mrofnocnon
@mrofnocnon 9 ай бұрын
Not tripping the roll out switch when you tried it as the door was off. When a rooftop has be running for some time, what could possibly cause the blower motor to reverse? Same with the slight gas overpressure, it's been that way for some time. I think I would have replaced the rollout switch as well as correcting the manifold pressure and also checked fan static pressures.
@josephgarcia676
@josephgarcia676 Жыл бұрын
That’s some funny looking stairs man I hear ya, I’m electrician. I’ve never seen that like that before I ever right on brother I subscribed.
@HVACKnowItAll
@HVACKnowItAll Жыл бұрын
I appreciate it!
@DanO181919
@DanO181919 4 жыл бұрын
Really like the short videos. Thanks for sharing!
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
I like them short too, to the point haha!
@joeschneider8025
@joeschneider8025 2 жыл бұрын
I had all them symptoms so I started replacing parts started with flame sensor then I tried pressure sensor and fixed it both parts cost me under $30 I'm just glad I didn't have a dirty coil or a vent clogged
@HVACKnowItAll
@HVACKnowItAll 2 жыл бұрын
Those parts prvented a flame roll out?
@jrh86
@jrh86 9 ай бұрын
Nice work 💯👍👍👍
@Abuhummus
@Abuhummus 4 жыл бұрын
Thanks for always putting out these informational videos. I appreciate it bud
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Thank you and no problem
@agsmith001
@agsmith001 3 жыл бұрын
nice job! i had a water heater bust and flood next to the hvac and trying to dry the area tripped my rollouts = easy fix! thanks youtube!
@daviddesilva4971
@daviddesilva4971 4 жыл бұрын
Great diagnosis...keep up the great vids.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Thank you!
@bababooey7576
@bababooey7576 4 жыл бұрын
A fellow GTA'er. Already subscribed. Thanks for the videos.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Thank you!
@navidd1971
@navidd1971 2 жыл бұрын
Outstanding. Fixed my problem.
@justincanterbury2561
@justincanterbury2561 4 жыл бұрын
Thanks
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
My pleasure
@connorpeacock4750
@connorpeacock4750 Жыл бұрын
Hoooooo Clarkson buddy you’re in my area !
@jonathanraul4086
@jonathanraul4086 4 жыл бұрын
Thanks nice video
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
My pleasure
@HughesManHVAC
@HughesManHVAC 4 жыл бұрын
Well done 👍
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Thank you sir!
@MrPro56
@MrPro56 Жыл бұрын
Hey buddy today my furnace went out same flame rollout switch problem, had guy come to check says the pressure control valve assembly needs replacement because pressure is off. It would take almost a grand to replace and uncertain wait time for the parts. How did you change the pressure to make the gas control valve work again? The technician didn't even bother to adjust it and told me it needs replacement.
@HVACRSurvival
@HVACRSurvival 4 жыл бұрын
I wonder if snow cut off the combustion air vents? Or just a weak limit?
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Didn't snow really, maybe or hopefully the elevated gas pressure was just enough
@HVACRSurvival
@HVACRSurvival 4 жыл бұрын
@@HVACKnowItAll sometimes I'll mount a temp sensor beside the limit and put the covers back on and watch what the temp does, if no where near the rating I'll change the limit. That looks like the Armstrong I changed the draft motor on in a video I posted a while back. Old turd needs a good flush down the toilet😳😉
@capitolrefrigerationheatin7501
@capitolrefrigerationheatin7501 4 жыл бұрын
nice fix, would checking temp rise and total external static pressure be going overboard? I have had calls were someone closed diffusers or fire damper closed increasing total external static and tripping high limit.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Yes of course if it tripped the limit, I would have checked that for sure
@jasonlyons4484
@jasonlyons4484 4 жыл бұрын
I had a Trane RTU a couple months ago where it would run ok but when I put on the door the flames would come back at me. It was -28*C on a Friday night, so I cut a hole in the door. Later I replaced the inducer and it seems to be good now.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Nice, thanks for the share!
@actechformallyyomama746
@actechformallyyomama746 4 жыл бұрын
Always check amperage on both legs of the induce motor. I had one that would explode like a shotgun. Turns out I was only drawing amps on one leg. This decreased the rpms and this caused the booming effect.
@samuelhartness9855
@samuelhartness9855 4 жыл бұрын
Do you ever check the heat exchanger with combustion analysis? It’s a method we use down south and it saves having to tear apart the unit to visually inspect the exchangers.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Yes I do use a CA, but the only way to find a crack is to locate is visually.
@samuelhartness9855
@samuelhartness9855 4 жыл бұрын
HVAC Know It All but if your co ppm, o2% and excess air % are out of range that tells you the exchanger is cracked and you wouldn’t need to break the unit down to get a visual.
@Abuhummus
@Abuhummus 4 жыл бұрын
Samuel Hartness True.... what’s wrong with a good old visual? Sometimes this CA act up... just saying. I agree with both methods, I just don’t see anything wrong with a visual
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
You could have those symptoms with plugged burner orifices or perhaps even RPM reduction in induced draft motor. I wouldn't trust a CA to tell me the heat ex is cracked myself
@samuelhartness9855
@samuelhartness9855 4 жыл бұрын
Yusuf Ata I don’t see anything wrong with it. It’s always easy to check on packs. But I work in residential so we have a lot of split units and it just wouldn’t be feasible to take the unit apart and inspect. A bore scope can only go so far as well, so we rely on the ca to tell us. That’s not to say that using the old method of sight and smell doesn’t happen. I’m just thinking in terms of saving time and using new technology to do more of the work.
@HARE118
@HARE118 Жыл бұрын
Where are you located?
@jake2213b
@jake2213b 4 жыл бұрын
How come you guys drive over an hour for a job. I can't get anyone drive 45 minutes. If they are not local forget it.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
I chose to live an hour outside the city 😆
@ethelryan257
@ethelryan257 3 жыл бұрын
My grandfather built up our firm against stiff competition to some degree because he was willing to work further out than the competition. Which my father did and I do and my two sons do, as well. Funny, but in over 70 years...not much has changed in that regard. We're still about the only firm which will do work out in the boondocks.
@bert1913
@bert1913 Жыл бұрын
when testing for roll out, I leave the cover on
@Mike-yh8tv
@Mike-yh8tv 4 жыл бұрын
Thanks for the knowledge.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Thank you, thanks for watching
@user-nt7gr4pp3b
@user-nt7gr4pp3b Жыл бұрын
you over think it
Flame Rollout!!! Finding the Cause! EP44
6:24
Nighthawk HVAC
Рет қаралды 96 М.
HVAC Companies HATE That You Can Do This Yourself.
25:51
The DIY HVAC Guy
Рет қаралды 535 М.
Cute kitty gadgets 💛
00:24
TheSoul Music Family
Рет қаралды 17 МЛН
나랑 아빠가 아이스크림 먹을 때
00:15
진영민yeongmin
Рет қаралды 4,5 МЛН
7 Days Stranded In A Cave
17:59
MrBeast
Рет қаралды 96 МЛН
Carrier  Rooftop Gas Valve Replacement After Going Off On High Limit
5:10
HVAC Know It All
Рет қаралды 2,5 М.
Flame rollout from a blocked heat exchanger, gas furnace
3:39
grayfurnaceman
Рет қаралды 165 М.
Furnace Flame Roll Out Switch Tripped - How it Works
6:58
Word of Advice TV
Рет қаралды 552 М.
Gas Company Locked Out The Meter - Said There Was Gas Leak
4:53
HVAC Know It All
Рет қаралды 18 М.
Dual Fuel Heat Pump Install Tips - How To Install A Heat Pump
18:53
HVAC Know It All
Рет қаралды 26 М.
Multi-zone split type Air Conditioner installation
16:49
craftsman tv
Рет қаралды 386 М.
Evaporator Delta T vs Evaporator Temperature Difference
2:56
HVAC Know It All
Рет қаралды 2,6 М.
POOL HEATER TROUBLESHOOTING; RAYPAK HEATER REPAIR
4:35
Steve The Pool Guy
Рет қаралды 21 М.
Gas Furnace Won't Turn On? Nothing Happening? 8 Reasons Why!
12:08
AC Service Tech LLC
Рет қаралды 492 М.
How to Jump Pressure Switch on Furnace
7:00
Word of Advice TV
Рет қаралды 700 М.
Cute kitty gadgets 💛
00:24
TheSoul Music Family
Рет қаралды 17 МЛН