Smart Valve Operation on a Gas Furnace!

  Рет қаралды 83,239

AC Service Tech LLC

AC Service Tech LLC

Күн бұрын

Пікірлер: 102
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
-Our E-book, Paperback, Workbook, Quick Cards, PowerPoints, www.acservicetech.com/store -Posters, Book, Workbook, Cards on Amazon: www.amazon.com/shop/acservicetech -Our E-book: play.google.com/store and iTunes and search "ac service tech" -Posters & PowerPoints on our Website: www.acservicetech.com/store Spanish Paperback and E-book: www.acservicetech.com/libros-en-espanol -Furnace and Thermostat Quizzes- www.acservicetech.com/quizzes -Our Website has FREE Videos, Calculators, Podcasts, Articles, Tips, Quizzes, Q/A: www.acservicetech.com -Facebook Tips: facebook.com/acservicetech -Tools we use, Our Book, Workbook, and Quick Cards: www.amazon.com/shop/acservicetech -Join our updates list for an email strictly from us for new videos, articles, products and website features! www.acservicetech.com
@itz_mohittt869
@itz_mohittt869 4 жыл бұрын
Sir suggest me best adjustble wrench for tight flair nut. Available in india
@Rinebo
@Rinebo 2 жыл бұрын
I can’t thank you enough for these videos! I’m on break from work and these are helping me sharpen up before going back!
@clucknorriz6683
@clucknorriz6683 3 жыл бұрын
You make great videos Your instructions are impeccable. I spent 32 years in the field and now I sell HVAC supplies equipment for a major wholesaler in Las Vegas, when some of the young guys get stuck over the phone I revert them to your videos, and tell them to subscribe
@NorCal-refrigeration
@NorCal-refrigeration 4 жыл бұрын
I wonder how many of us techs call them the dumb valve. 😂
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
I am sure many, thanks Nor-Cal! You do great work!
@joerice1372
@joerice1372 4 жыл бұрын
I know I do.. I absolutely hate smart valve
@lizarraga337
@lizarraga337 4 жыл бұрын
@thomaswilliams8624
@thomaswilliams8624 2 жыл бұрын
😅😅😅😅😅😅
@timrob0420
@timrob0420 Жыл бұрын
Ngl if I see one of these on an older furnace 19-20 years old and it’s having issues I try to get them to get a new furnace
@Sctronic209
@Sctronic209 4 жыл бұрын
Great explanation your a great Instructor.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thank you very much HVAC1!
@rodgraff1782
@rodgraff1782 4 жыл бұрын
Honeywell smart valve with intermittent pilot and 24 volt hot surface ignitor was one of the most troublesome systems when I was in the trade. Close second to the White Rodgers mercury flame sensor, intermittent pilot with lock out.
@felixtrejo4542
@felixtrejo4542 4 жыл бұрын
As always great video!! Thank you Craig for sharing your knowledge.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Glad you enjoyed it
@SombraLocs
@SombraLocs 4 жыл бұрын
You're dropping gems!
@toddbehrends1373
@toddbehrends1373 4 жыл бұрын
Merry Christmas and Happy New Year to you and your company. I have 2 favorite channels and yours is 1 of them. I am not a tech, but this knowledge is helpful when a problem arises in one of the units at a rental house. I can diagnose a problem and then get the parts, or some more help, to fix the problem.
@hkhsm359
@hkhsm359 4 жыл бұрын
Great knowledge and explanation. Thanks for sharing
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
My pleasure
@TheMaximomex
@TheMaximomex 4 жыл бұрын
Thank you for these videos. They help a lot.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Glad you like them!
@martinm7912
@martinm7912 4 жыл бұрын
Great video! Thank you
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Glad you liked it!
@brettmorgan5612
@brettmorgan5612 4 жыл бұрын
Another very informative video. I can’t watch enough of these. Thanks for all your time and effort.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
I appreciate that Brett!
@jonathanraul4086
@jonathanraul4086 4 жыл бұрын
Great video once again thanks for sharing your knowledge you're the man
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
I appreciate that!
@monsantofungaro5704
@monsantofungaro5704 4 жыл бұрын
Great video, so easy to follow along and understand. Thank you very much!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
You're very welcome!
@johnrandich
@johnrandich 6 ай бұрын
Loved the info pal . Thku!!!!
@jeffarney7762
@jeffarney7762 4 жыл бұрын
I would love an explanation on the old Bryant/Carrier 3 wire pilot burners. The ones with the circuit board behind the inducer motor!! Very informative video btw!
@clucknorriz6683
@clucknorriz6683 3 жыл бұрын
Aggh the old 671, what do you want to know about it?
@clucknorriz6683
@clucknorriz6683 3 жыл бұрын
ICM makes a board for it I believe it's A278 the ICM 278.
@jimmysegovia2688
@jimmysegovia2688 4 жыл бұрын
awesome vid!!! thanks craig for sharing.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks for watching!
@tjriver6653
@tjriver6653 Жыл бұрын
like this guy help the world, thank you alot.
@pizzle1011
@pizzle1011 4 жыл бұрын
Great video... happy holidays!!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Happy holidays!
@gmac280
@gmac280 3 жыл бұрын
Another great instructional video!
@craigkachadorian7793
@craigkachadorian7793 4 жыл бұрын
Thank you Craig
@mrwill1779
@mrwill1779 3 жыл бұрын
great video
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you enjoyed it
@jedcusimano1973
@jedcusimano1973 2 жыл бұрын
Great Video. Very Helpful, but still stumped. I have power coming from the board on the blue wire through the pressure switch (verified it is closed) to the end of the 4 pin harness but still no power to ignitor. I also tested all the other safety switches and all are closed. No power coming back on orange wire since ignitor not getting power. Any suggestions?
@frankduarte7109
@frankduarte7109 2 жыл бұрын
Did you ever figure this out? Ima say bad gas valve?
@ANIMALHOUSEBEATZ
@ANIMALHOUSEBEATZ 2 жыл бұрын
Very informative video. I have a better understanding now. I'm having problems with the furnace right now. I have Honeywell smart valve and it seems it's not clicking to release the gas. Also notice the igniter is not glowing. I'm going to buy a multimeter to diagnose this.
@sparkyobrian6417
@sparkyobrian6417 Жыл бұрын
excellent video; im waiting for the poe or can bus thermostats to show up as it easier for engineers to design and cheaper to build, thus making the techs job harder.
@frankduarte7109
@frankduarte7109 2 жыл бұрын
Great video!!
@SuperVstech
@SuperVstech 4 жыл бұрын
The smart valve came out as a consolidation of the safety flame controls. Back in the day, 80%and higher furnaces needed ignition and flame proofing. The smart valve was just a Honeywell decision to integrate the safeties. Makes a cheap board into an expensive gas controller. Forcing expensive replacement parts WHEN a component fails. Modern systems use a single control board, and separate modular devices... far better for the consumer.
@richardsotnick6414
@richardsotnick6414 4 жыл бұрын
I recently had a problem with my furnace. Pilot would light but main burners would either not ignite or they would ignite and immediately turn off. Checked flame detector, okay. Called technician and he condemned smart valve. I said thanks but no thanks. I investigated further and the problem was a high resistance multi contact thermostat. Smart valve was getting sufficient voltage to light pilot but not enough 24 V voltage to light the main burners. Changed thermostat and problem disappeared. Lesson is just because thermostat turns on exhaust blower, doesn’t mean thermostat is good. It may be high resistance. Jumper out thermostat to prove furnace works properly. Don’t assume thermostat is okay if blower comes on.
@richardsotnick6414
@richardsotnick6414 4 жыл бұрын
What I mean by a multi contact thermostat is a Honeywell Chronotherm with heat on/off switch, backplate wipers and main (mercury) contacts. There was just too much resistance in all these contacts.
@jkbrown5496
@jkbrown5496 4 жыл бұрын
You can track the voltage drops in the readings he takes in the video. Starts with near 28v on R-C, then around 27.3 when the inducer motor starts and the relay coil is flowing current. Then the hot surface igniter kicks in, we see 16v quickly going to 23v, then 25.9v from the valve to the control board. I believe 22v is the lower limit for reliable operation of the gas solenoids. If the extra resistance drove the voltage lower when both the hot surface igniter and gas solenoid are powered for initial ignition of the flame, it could cause the solenoid to slip cutting off the gas, killing the flame even if it reopened. Even in the video we see the voltage on the hot surface igniter is 16v for a split second as it heats up, but that could be meter response and maybe the hot surface igniter is powered a split second before the gas solenoid to avoid those inrush voltage drop problems.
@johnkirchner9979
@johnkirchner9979 4 жыл бұрын
Or resistance on the hot surface ignigtor changes when it glows red
@vongrayson9047
@vongrayson9047 2 жыл бұрын
The high efficiency units that use PVC for combustion gas create "water" from the exchanger rem,oving so much heat the moisture in the air" condenses" . The old school 80% efficient units that use meatl flue pipes vent discharge air hot enough to burn off the moisture. Until the metal flue pipe gets hot they will condense for a few minutes too.
@joerice1372
@joerice1372 4 жыл бұрын
Craig do you have any videos on the recognition smart valve with the 120v ignitor? Ran across one the other day.. I’d love to get an idea of what that extra plug is!
@thatnewsmananimated7677
@thatnewsmananimated7677 3 жыл бұрын
Great thanks Master
@1commonsense934
@1commonsense934 2 жыл бұрын
Great job explaining...I have a smart valve that is clicking repeatedly after flames are on..then will relight...also noticed that a small blue pilot flame with all power off ...what's your thoughts ??
@own0805
@own0805 Жыл бұрын
did you get this resolve? im having the same problem. i hate this smart valve
@1commonsense934
@1commonsense934 Жыл бұрын
@@own0805 yes..the 2nd heat exchanger drain tube was cracked.. leaking water and air sealed it with duct tape.. working !
@watermanone7567
@watermanone7567 4 жыл бұрын
Excellent video. What kind of furnace was the smart valve on? I have not done many smart valves to really enjoyed the video. Many thanks.
@clucknorriz6683
@clucknorriz6683 3 жыл бұрын
Looks like a ICP, Tempstar.
@nickrhine6403
@nickrhine6403 4 жыл бұрын
Will you be making a video for the direct ignition smart valve, ive been working on a lot of tube heaters and hanging garage units with the direct ignition valve
@biblebloopers946
@biblebloopers946 3 жыл бұрын
1 question... After flame is proven through rectification, and the main gas valve opens, does the pilot flame stay on or does it turn off while your burners are going? Thank you
@tomoliver8498
@tomoliver8498 3 жыл бұрын
Pilot stays on when main gas valve opens because pilot assembly is where the flame proving sensor is located.
@Straycurrent
@Straycurrent 4 жыл бұрын
A very helpful video- thanks for the training. I wonder what are the pros and cons about this type of intermittent pilot versus direct ignition of burners by HSI?
@AIRCONDITIONINGSCHOOLING
@AIRCONDITIONINGSCHOOLING Жыл бұрын
How does the main control board know there is a flame ? How doesnt it shut off while it runs?
@astindersinghera766
@astindersinghera766 3 жыл бұрын
Well explained gas furnace operation and individual components functions. I have a question, my furnace intermittently cutting in and out with clicking sound before it fires up. Is this appear to gas valve issue and can it be repaired instead of replacing them. The gas valve is quite pricey. Thanks for your help.
@chamberlain9268
@chamberlain9268 17 сағат бұрын
If anyone is here with the same problem I had. Honeywell Sv9541 gas valve does control the ignition sequence. If you are having inducer motor not turn on or flame its the gas valve and it may have a solid green light showing. I replaced control board first and it didnt fix issue.
@ajkelly6135
@ajkelly6135 Ай бұрын
I have a sv9500m 2603 I have three wires yellow red and white how would I go about adding a smart thermostat
@hedgewoodtv
@hedgewoodtv Ай бұрын
Can you confirm if the control board is responsible for initiating the inducer motor? My issue is when I call for heat my inducer motor won't even start. I've verified the motor is good, and that I have 28v between r and w. I'm about to replace the control board. But I'd like to know that it's not the smart valve not allowing the inducer to start also.
@chamberlain9268
@chamberlain9268 17 сағат бұрын
Hey . If its a honeywell smart valve it will control the power sent to inducer motor. I tried a new board and it didn't fix problem. The gas valve has a solid light on and wont turn my fan on. Apparently its the gas valve and they are notoriously bad.
@chesstime356
@chesstime356 4 жыл бұрын
Very nice I like your explanation... I am new to the field and I hope one day become good tech. I do watch your video from different accounts both under my Mohammad name
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
So nice of you
@walteraustin288
@walteraustin288 3 жыл бұрын
Been trying to find that type of style of flame rod surface ignitor but the model sticker fell off my old one
@thefred0215
@thefred0215 3 жыл бұрын
Great Video yet again Craig. So once the 24v comes from the pressure switch, does that same voltage open the pilot valve?
@SKRRTSKRRTx
@SKRRTSKRRTx 4 жыл бұрын
Hey Craig, I have this smart valve and I think the flame rod needs cleaned. Do you have to remove the whole assembly to access it?
@kyleh1974
@kyleh1974 4 жыл бұрын
Was there some perceived benefit of the smart valve system? Never understood why these even exist.
@MindKontrolleProject
@MindKontrolleProject 3 жыл бұрын
What would cause the outlet/manifold gas pressure change over time?
@ronaldfuhrer
@ronaldfuhrer 3 ай бұрын
Why does my smart valve only open if I turn the switch off and back on again, then it opens and completes the sequence?? Do I need a new dumb valve ?
@DaBorderhopper
@DaBorderhopper 3 жыл бұрын
so my issue i have is the igniter glows but the valve isnt letting gas pass to the pilot tube i heard it clicking open but no gas passing through?.. everything electrical looks good everything works but no gas is passing through.. any idea what would cause this or is the valve definitely bad like im thinking.
@APECK636
@APECK636 4 жыл бұрын
Hey man I have a Gray Top smart valve I am trouble shooting. Inducer comes on, then quits I get 3 flashes. Which is a draft issue. I jumped the pressure switch circuit then the burners fired up. Going to use my manometer tonight and see what the draft motor is pulling. I need to rule out any flue obstruction too. Anything else I should check?
@clucknorriz6683
@clucknorriz6683 3 жыл бұрын
You could actually disconnect power to the pressure switch and hook up your meter ends on it and on the tubing that's connected to the pressure switch suck on it and see if you get a beep on OHM setting if you do that might tell you the switch is OK but then you'll have to use the monometer to check the pressure switch itself, otherwise check for obstructions in the B vent but I believe your problems linked to the pressure switch Does the fan motor run continuously when you turn on power to the unit
@kamalnasari8632
@kamalnasari8632 4 жыл бұрын
H N year ❤
@EnjoyCalculus
@EnjoyCalculus 3 жыл бұрын
I still don't understand why the gas valve has 2 separate sources of 24v going to it (black and white as well as the blue)
@orlandochairez7369
@orlandochairez7369 3 жыл бұрын
So I have power going to my Hot Surface Ignitor but nothing happens I changed it and new one does the same. I have power going to it but it does not light. But I give it 24v straight out of transformer and it lights up. What am I missing
@patrickjordan8373
@patrickjordan8373 2 жыл бұрын
Anybody have a list of machines that do NOT have smart controls in 2022?
@israelalessandro1239
@israelalessandro1239 4 жыл бұрын
Very happy 😍💋 💝💖♥️❤️
@danielbergey3358
@danielbergey3358 4 жыл бұрын
Why a smart vavle when you have the control board and all the normal wiring. Seems like they just want to jump the price a a 24volt valve.
@zack9912000
@zack9912000 4 жыл бұрын
Smart valves are garbage, hence why no new furance uses them. Honeywell makes the worst gas valves
@allykatt940
@allykatt940 2 жыл бұрын
first take off panel then put FAU in the trash
@Rhahdhdn
@Rhahdhdn 4 жыл бұрын
I hate these smart valves. So expensive when you have to replace them.
@channelcatchaser9426
@channelcatchaser9426 4 жыл бұрын
$60 dollar ignitor.
@zack9912000
@zack9912000 4 жыл бұрын
OEM cost more then that, 60 dollar ones are the universal
@throttlebottle5906
@throttlebottle5906 4 жыл бұрын
ahh, the most anti-smart, smart valve I've ever seen
@timrob0420
@timrob0420 2 жыл бұрын
I hate those POS valves
@tomoliver8498
@tomoliver8498 3 жыл бұрын
Smart valves suck
Quickly Testing Gas Furnace Safety/Limit Switches!
5:37
AC Service Tech LLC
Рет қаралды 189 М.
Honeywell Smart Valve Operation, Testing, Wiring! HVAC Gas Furnace Training!
18:40
It works #beatbox #tiktok
00:34
BeatboxJCOP
Рет қаралды 41 МЛН
1% vs 100% #beatbox #tiktok
01:10
BeatboxJCOP
Рет қаралды 67 МЛН
Quando A Diferença De Altura É Muito Grande 😲😂
00:12
Mari Maria
Рет қаралды 45 МЛН
Gas Furnace Training Class! Basics, Operation, Components, Troubleshooting
1:20:49
Gas Furnace Turning Off? Here's What Might Be Happening
15:56
Taddy Digest
Рет қаралды 277 М.
Troubleshooting a Gas Furnace
23:20
Anti DIY HVAC
Рет қаралды 32 М.
Furnace Gas Valve Not Opening - How to Fix It
8:16
Word of Advice TV
Рет қаралды 134 М.
Scammers PANIC After I Hack Their Live CCTV Cameras!
23:20
NanoBaiter
Рет қаралды 25 МЛН
Smart valve / intermittent gas furnace
58:10
Love2HVAC with Ty Branaman
Рет қаралды 27 М.
Gas Furnace SPARK IGNITION Operation and Testing!
17:07
AC Service Tech LLC
Рет қаралды 107 М.
HVAC Silver Soldering vs Brazing vs Brazing While Flowing Nitrogen!
18:42
AC Service Tech LLC
Рет қаралды 155 М.
Honeywell Intermittent Pilot Training
14:15
Neuco
Рет қаралды 87 М.
It works #beatbox #tiktok
00:34
BeatboxJCOP
Рет қаралды 41 МЛН