Freezer at 40 degrees but checks out ok when I get there.

Пікірлер: 65
@derrickowens3072
@derrickowens3072 8 жыл бұрын
awesome video man I knew nothing about refrigeration until I started watching all your videos please keep em coming
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
Thanks for watching. Will do.
@oliverbranson5565
@oliverbranson5565 8 жыл бұрын
Nice video! Thanks for sharing your experiences, very helpful.
@Gears.and.Gadgets
@Gears.and.Gadgets 8 жыл бұрын
good video. I have replaced many of those sensors. Glad I got training from Traulsen when I did a few years back.
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
I think it was late 90's when that stuff came out. We all freaked out at 1 st but it has actually been pretty good stuff. That the 1st break down this unit it's 11 years old. Not bad.
@Gears.and.Gadgets
@Gears.and.Gadgets 8 жыл бұрын
No not bad at all. When I was back at Hobart we cross trained in the Traulsen units too. I still have the master service manual on those.
@raviyadav8743
@raviyadav8743 2 жыл бұрын
Hii sir, we have 3 door Tralsun freezer ,the Controller not giving correct temp reading,even I changed Original Green colour Cabinet probe.when I check with Digital thermometer cabinet temp was 0°F but freeze controller was showing 14°F
@davejohnsonnola2758
@davejohnsonnola2758 7 жыл бұрын
Thanks for all the vids, but especially on the testo probes. I am in F&B operations at a horse race track but have also taken on "first responder" duties for refrigeration and beverage equipment problems. Try to weed out the minimum wage "operator error" calls and take care of easy fixes, as well as implementing a condenser coil cleaning schedule. We have a lot of 20 yr old equipment from when the facility was rebuilt after a fire, so just about every other day there is something going down, between two large kitchens, seven bars and six concession stands. Just bought a testo pressure and temp probe to add to my toy box. Still need to call the pros when its time to pass gas or anything heavy or complicated, but wanted to get the tools to add to my diagnostic skills. Finally going to take the EPA test damn near 30 years after earning an HVAC degree in community college, but never going in to the field.
@hvac01453
@hvac01453 5 жыл бұрын
Was working on a True 2 door reach in freezer the other day, with a dual cap tube. Not freezing properly I cut back the cap tubes 3 inches or so and a new drier and weighed in the 404a charge. The compressor was noisy before and a history of it being noisy. During an efficiency test it took a full 5 minutes to pull down to 8"and it climbed back up positive in under 1 minute. I was taught it should pull down to 16" in less than 1 minute once it hits 0, and should hold for 5 min. My After 20 minutes of run time it went from 50 down to 23, but the superheat was 90at the compressor, and 20f Sub cooling. The high side was 115F cold temp in an 80F room. Most tech say disregard these readings till it reaches temp =/- 5F. my low side was about 16PSIG. Ill find out Tuesday if it reached temp I guess. One problem was the customer pushed these boxes inside the box, up against the back inside wall of the reach-in. The top shelf was piled up to the fan. I assumed this was half the problem on why they said one side would freeze and the other would be soft.
@hvac01453
@hvac01453 5 жыл бұрын
115F condenser temperature (auto correct), also +/- 5F
@davidhodgin3792
@davidhodgin3792 4 жыл бұрын
Read the probes through intel a traul and you would not have to gauges on it. Coil sensor is most likely issue. CB and EL in CUS mode. Unplug the coil sensor and control will operate of time only for defrost. Always use sensors that have GB on them.
@randallchittenden6825
@randallchittenden6825 5 жыл бұрын
Nice video. I am servicing our Traulsen 2 1/2 door model. First issue was about 18 months ago when the unit started to freeze up on the evap coil. We thawed the unit and it took another 18 months to freeze up again. I downloaded the customer service manual and learned a few things about our unit. Good thing, because after unplugging it, the temp setting was at 35F. I set the temp to -4F, 2 degree offset was factory, and the date and time were put in. During the cooling and defrost cycles, I access the Cb and El temps. Cooling cycles, the temp probes are in line with freezer temp. During defrost, the Cb and El are 35 and 37F respectively. That tells me the Heater is working. Now, the evap fan is supposed to shut off during the def mode and open door. That does not happen. I am wondering if this is why the unit if freezing back up. If frozen air if forced up into the evap box, the edges away from the heater may remain cold until the unit freezes over. Thoughts?
@greentea111
@greentea111 4 жыл бұрын
i am installing one module tomorrow for uno's pizza THank you for the tips
@kingofthecrease30
@kingofthecrease30 8 жыл бұрын
you can check the calibration of the probes from the controller...CS is cabinet sensor and there is one for evap sensor....might be ES...not sure. that interface needs to be replaced cuz its flickering too much....coil will freeze up is probes are out of calibration
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
Your correct you can check the EVAP probe temp on the display I forgot that.
@skycassidy6557
@skycassidy6557 17 күн бұрын
Love your videos, thank you. I have a question for a 3 door Traulsen freezer. The compressor switch was clicking on and off and the motor would just barely move each time. I replaced the switch and now everything seems normal except the motor doesn't turn on at all now. The display shows the temp (86) but nothing happens. The door frames do get hot. I have also swapped out the Start Capacitor. Any ideas on what's wrong?
@NorCal-refrigeration
@NorCal-refrigeration 17 күн бұрын
@@skycassidy6557 check for voltage at compressor and work your way back
@harrydickson4575
@harrydickson4575 8 жыл бұрын
Excellent video
@raviyadav8743
@raviyadav8743 2 жыл бұрын
Hello sir,What the reason Temperature controller not showing correct temp reading .Even I replaced New Green Colour Cabinet probe. There is almost 10° different reading when I check with Other Thermometer.
@20antman
@20antman 8 жыл бұрын
those intermittent issues suck for you and the customer. I guess its something we have to deal with in this field. But it has been seen more with all the electronic stuff. nice video bro
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
It has. The old electro mechanical controls were easy and good.
@BlackHawkPSU
@BlackHawkPSU 7 жыл бұрын
I have to replace a True T-23 and I think I will get another T-23. It was between the True and a Beverage Air unit. I hear good things about Traulsen, but don't know anyone on the east coast that has one.
@poppypiesdad1
@poppypiesdad1 8 жыл бұрын
great vid again, keep them coming
@kingofthecrease30
@kingofthecrease30 8 жыл бұрын
I got the testo 550 and the smart probes...good stuff...as far as tool bags go...I invested in a veto pro pac bag...best bags money can buy hands down...expensive but so worth it
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
I've look at those but I like the handle on the clc it fits over my forearm when I climb up ladders.
@randomrefrigeration4564
@randomrefrigeration4564 Жыл бұрын
Where in the world did you get that Traulen book of parts ??????
@NorCal-refrigeration
@NorCal-refrigeration Жыл бұрын
Refrigeration hardware supply catalog it’s the parts book for all brands. 🤘🤘
@jimbola77
@jimbola77 8 жыл бұрын
Great video!!!!!
@Pyridox
@Pyridox 8 жыл бұрын
Nice job!
@heavydiesel
@heavydiesel 8 жыл бұрын
Awesome stuff! I can never remember the codes for controllers. Sometime all you can do is give it your best guess based on experience!
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
There's so many different controls out there it's nuts.
@RobertAziz26
@RobertAziz26 8 жыл бұрын
Great video, very helpful. Thank
@LooseLoad
@LooseLoad 4 жыл бұрын
Working on a g3101jc 3 door reach in. Defrost heater stays on even if EL set temp is reached. I'm suspecting the relay module. What do you think?
@airmechanical7163
@airmechanical7163 8 жыл бұрын
Good video!
@hardcooling
@hardcooling 8 жыл бұрын
👍 thumbs up from me on this one bro good job
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
Thanks HC
@hvacservice
@hvacservice 7 жыл бұрын
Nice video. I am working on the refrigerator same controller and it cools to 36.6 then instantly starts climbing up to 46 within a couple minutes then cools back down. The SPH/SPL are set correctly and my charge is perfect. Any ideas? Thanks man I appreciate any insight.
@SombraLocs
@SombraLocs 7 жыл бұрын
Great video!
@apr9286
@apr9286 8 жыл бұрын
Update: I'm getting voltage on the purple defrost line as soon o plug it back in. Is this correct? My take is that it should only have voltage during defrost not sure??. I ohm out the heater all good. I think I need a new rely box. Any advice? Thank s
@russell4309
@russell4309 4 жыл бұрын
Have you seen the traulsens with the key switch for refer/ freezer combos? How does that works with 1 compressor?
@NorCal-refrigeration
@NorCal-refrigeration 4 жыл бұрын
I have not seen that one.
@hvac.r_mn
@hvac.r_mn 8 жыл бұрын
The sensor you refer to off the control is that tested by resistance readings?
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
Yes it is.
@chubbydickschopshop
@chubbydickschopshop 5 жыл бұрын
What’s the evaporator coil temp when the evaporator fan should come on.
@atch_n_sons
@atch_n_sons 5 жыл бұрын
Cab and coil sensors are 32 k ohm @ 32 * f
@jonhvac
@jonhvac 8 жыл бұрын
Really good vid Dave! Great smart probes demonstration son. Man I hate when there's nothing wrong when you get there...foc! haha. I also hope an evap fan isn't failing. Is this that Chinese place with the traps in the walk-in? Tom Powell woot woot!
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
This is another place very busy, the intermittent shuffle sucks the most. Lol.
@steveomac5001
@steveomac5001 2 жыл бұрын
NorCal, I need your help on a traulsen, anyway I could get a hold of you? Email or something
@RobHVAC
@RobHVAC 8 жыл бұрын
Another good video.
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
Thanks Rob
@apr9286
@apr9286 8 жыл бұрын
I have a similar problem with a traulsen freezer not going into defrost I did what you did went into the custom settings and went to manual defrost, check for amperage on the defrost line and I have zero. Do you think it's a bad element?
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
Check voltage if you have volts and no amps then the heater is bad. You can ohm out the heater also to check it.
@thomaszawoysky21
@thomaszawoysky21 8 жыл бұрын
great video I changed the coil sensor and now defrost works. the evaporator fan still won't come on I checked the cabinet sensor and it ohmed out good. I'm lost any suggestions
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
EVAP fan has a 2.5 min. Delay. If it dose not come on after that start at the relay pack.
@thomaszawoysky21
@thomaszawoysky21 8 жыл бұрын
Thanks
@raviyadav8743
@raviyadav8743 6 жыл бұрын
Sir I have one tralsun 3 door freezer .. Always ice farming on fan ..So fan stop working .Plz give me solution ..Thankz
@NorCal-refrigeration
@NorCal-refrigeration 6 жыл бұрын
Ravi prakash yadav could be many things. But start at the evap sensor there is an ohms valve to temperature to check it. Test your defrost cycle. Compressor cycles off fan off heaters on. Check defrost heaters.
@philltafolla
@philltafolla 8 жыл бұрын
Nice video Dave ,hey you order your parts from RHS?
@NorCal-refrigeration
@NorCal-refrigeration 8 жыл бұрын
Yes them and case parts, you have to call both because the price can vary a lot.
@philltafolla
@philltafolla 8 жыл бұрын
Nice I have an RHS 5 min away from my house . It's the Sun Valley CA location.. Nice video like those Testo probes..
@hvactechpr7872
@hvactechpr7872 7 жыл бұрын
yanked the controls and modded in a defrost timer and freezer tstat...
@hvactechpr7872
@hvactechpr7872 7 жыл бұрын
did one about 2 yrs ago.... its a pain to get parts here.... so we gotta do what you gotta do...
@polishtheturdmickelson5473
@polishtheturdmickelson5473 6 жыл бұрын
I love it, good for you for doing it. 👍
@SombraLocs
@SombraLocs 7 жыл бұрын
I'm getting a code of 266, on a freezer. It's not freezing.
@polishtheturdmickelson5473
@polishtheturdmickelson5473 6 жыл бұрын
Well built units, not a fan of that controller.
A Good refrigeration service video
15:34
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 9 М.
Traulsen repair
15:00
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 11 М.
Fake watermelon by Secret Vlog
00:16
Secret Vlog
Рет қаралды 3,1 МЛН
У ГОРДЕЯ ПОЖАР в ОФИСЕ!
01:01
Дима Гордей
Рет қаралды 5 МЛН
PEDRO PEDRO INSIDEOUT
00:10
MOOMOO STUDIO [무무 스튜디오]
Рет қаралды 24 МЛН
Traulsen not cooling
10:05
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 12 М.
Online HVAC Training
3:56
Ron Walker
Рет қаралды 50 М.
Traulsen Freezer Service Call
14:18
HughesMan HVAC
Рет қаралды 2,9 М.
Another EVAP coil changed
12:19
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 7 М.
HOW FREEZER DEFROST TIMER OPERATES - PART 2
8:19
Charles PEN
Рет қаралды 118 М.
Traulsen G22010 Freezer Repair
12:20
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 11 М.
Traulsen SER-60711-05 KIT MIT TO NGC RETROFIT
6:00
GTJD Restaurant Tech
Рет қаралды 619
Reach in freezer warm
8:10
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 7 М.
Fixing up the Kirovets tractor (K-700A) - Ep3
3:49:32
Ants Pants
Рет қаралды 27 М.
Fake watermelon by Secret Vlog
00:16
Secret Vlog
Рет қаралды 3,1 МЛН