Why is my fan running all the time with no heat

  Рет қаралды 305,622

grayfurnaceman

grayfurnaceman

Күн бұрын

Пікірлер: 159
@dancallahan2590
@dancallahan2590 7 жыл бұрын
Hey folks,this guy is good.Mr.Grey I had similar problem,the furnace was short cycling,shutting off the gas and starting again.But it was not the limit switches,it was the air filter that was too thick and restricting air flow. Thanks for helping us folks who can fix simple problems. You are the best.
@beephoon7489
@beephoon7489 4 жыл бұрын
You make the best video on oil furnace. I never get tired of watching your video. Very well explained and detailed information
@grayfurnaceman
@grayfurnaceman 4 жыл бұрын
You must have a boring life. lol GFM
@Molly-cl5pd
@Molly-cl5pd 4 жыл бұрын
Oh thank you so much sir!! You simplify the instructions so well I was about to tear my hair out!! I am so grateful!!!
@grayfurnaceman
@grayfurnaceman 4 жыл бұрын
Glad you got it going. GFM
@biartspencer
@biartspencer 2 жыл бұрын
Thank you so much for your help with my furnace. Limit switch must've activated due to a clogged air filter. Probably saved me $150.00 and the embarrassment facing the HVAC guy. Glad I wasn't too busy to deal with it myself.
@Yophillips3272
@Yophillips3272 3 жыл бұрын
This is the 2nd furance you helped me fix. Simple and straight to the point.
@waynemiles7027
@waynemiles7027 7 жыл бұрын
Tank you Mr. Grey for all you do for the hvac community.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Welcome GFM
@tonylaracuente7112
@tonylaracuente7112 7 жыл бұрын
thank you mr. gray furnace I learned a lot from all your videos in the past few years thank you very much
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Welcome GFM
@ronbrooks7808
@ronbrooks7808 Жыл бұрын
Thanks for the video, my relay was bad, board even had a little burn on it. $70, back in business. Cheaper then my $165 home warranty deductible!
@grayfurnaceman
@grayfurnaceman Жыл бұрын
Not a fan of home warranties. GFM
@jerryluth1533
@jerryluth1533 6 жыл бұрын
Your an excellent instructor, thank you for taking your time to help, Jer
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
Thanks for the support. GFM
@tonypointer7026
@tonypointer7026 3 жыл бұрын
Great video
@Mud55
@Mud55 6 жыл бұрын
Thank you Sir! That was well explained and the switch was the exact problem.
@augustinejames1168
@augustinejames1168 4 жыл бұрын
I like that this is a simple fix
@tre2472
@tre2472 7 жыл бұрын
Thanks!! This is my problem with my furnace.
@edbtzkhud
@edbtzkhud 7 жыл бұрын
Trey K replace the control board
@dcmoor4662
@dcmoor4662 5 жыл бұрын
How about a bad relay on your control board. I encounter this on a york diamond 80 the fan was on all the time in heat, cooling, and when t-stat was in the off position.
@intelin123
@intelin123 6 жыл бұрын
I learn so much from you than from my job
@Jeff_S...
@Jeff_S... 7 жыл бұрын
I've had quite a few with packed evaporator coils limiting airflow and coils with whole sheets of paper on them, that somehow made it all the way through. I've heard of dirty heat exchangers, but never found one myself.
@slappahoe8493
@slappahoe8493 4 жыл бұрын
Yes sir! I’ve had the same problems and finding the A coil packed
@geojor
@geojor 7 жыл бұрын
always great, thank you ...
@RC-Heli835
@RC-Heli835 4 жыл бұрын
I just had an easy one finally at my rental house. A mouse had chewed a hole in the vacuum line on the vent motor and the igniter wouldn't glow to start the burner. A while back the AC compressor had to be replaced at 1600 bucks. The year before that it needed a capacitor and Freon so nothing I could do.
@JoelGonzalez-us5hj
@JoelGonzalez-us5hj 6 жыл бұрын
Thank you mister...you help me a lot
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
Welcome GFM
@psicopatalucifer
@psicopatalucifer 7 жыл бұрын
Nice information.
@acrepairnearme
@acrepairnearme 7 жыл бұрын
Thank you. Evaporator coils also can be clogged.
@speway
@speway 7 жыл бұрын
First and for most a big thanks you to you Mr. Grey and a Happy New Year! I find this new year, at about 3 am, that a hum is coming from my vents and no hot air....no cold air either. Thermostat is reading 51 degrees F at present and outside temp is 14 F here in DC. It's about to get cold in here. I have family here from Philippians experiencing their first winter EVER. My issue is not rectified but I think the answer is found here in this vid.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Look for error codes on the furnace. Should be a small window in the fan cover to see the codes with a key on the inside of the door. GFM
@speway
@speway 7 жыл бұрын
You, my friend, are a whole lot of awesome! Forgive the latent response. I went into survival mode and purchased 7 medium room portable heaters to take the edge off.....1952 home no insulation just wall cavities. It was still cold. Regarding the error codes, my system does not have a read-out as such. The bread board does not have a digital read-out nor does it have any LED that would denote error. Nonetheless thanks to your vid on "Limiter Switches" I am back up and running real nice and toasty like.....hence my first statement. You literally make the world a warmer place...and or cooler place respectively.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Thanks for the support. GFM
@StorminNorman-sm8ro
@StorminNorman-sm8ro 6 жыл бұрын
My house is new and when it reaches the limit on the Thermostat it just starts blowing air and won't stop until I switch it off or turn the set temp down.
@jgharts4949
@jgharts4949 7 жыл бұрын
Thank you!
@tonyb9785
@tonyb9785 4 жыл бұрын
For me the ignitor and flame sensor needed cleaned with high grit sandpaper, I found this after looking at the code my furnace board was throwing (blinking light, google it), which pointed to the issue; if you're having problems, check the code if possible.
@dirktyssen5211
@dirktyssen5211 4 жыл бұрын
Our inducer motor never shuts off even when there is a call for ac. Heat turns on once , but that’s all she wrote until I kill the power to the furnace and then turn it back on. I am assuming this is because having the inducer motor running all time does not cause a neg pressure reading for the pressure valve to close and start the heating cycle. Everything checks out good with a meter for resistance including the limit switch. Is it just the relay on the board for the inducer motor stuck on? Any help would be much appreciated Dirk
@grayfurnaceman
@grayfurnaceman 4 жыл бұрын
I would first look at the relay. GFM
@RoadVentureRV
@RoadVentureRV 5 жыл бұрын
Thanks man this was supper helpful 😎❤👍
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
Welcome GFM
@markparkus6988
@markparkus6988 5 жыл бұрын
yes tyvm was the air filter
@rgo5062
@rgo5062 Жыл бұрын
Can this happen if the blower motor is going out?
@grayfurnaceman
@grayfurnaceman Жыл бұрын
It could happen, but very unusual. GFM
@castingflaw
@castingflaw 6 жыл бұрын
Mr.Grey.I have a Rheem criterion II gas furnace, guessing it was installed before 2007.Its now 9/2018,we have been running the A.C. with the warm weather and the blower motor (the small one that starts up before the glow plug lights up in the winter) will start and then stop, we have a old dial type thermostat.If we need to replace the thermostat will there be a problem if we have to go to a new style?
@douglasbrown1261
@douglasbrown1261 4 жыл бұрын
I have a crane rooftop furnace on a commercial roof what caused the inducer motor too working
@grayfurnaceman
@grayfurnaceman 4 жыл бұрын
I assume that's Trane. Is the inducer running all the time? GFM
@missiletm
@missiletm 5 жыл бұрын
Our blower runs automatically in our vacation home (mobile home) in Palm Springs during the summer when we’re not there and the inside temp is over 85 degrees or so unless we shut off the breaker when we leave. We’ve recently installed a smart thermostat to turn on the AC before we arrive but it’s useless if the breaker is turned off. Is there a way to fix this so the blower isn’t constantly running without killing the breaker?
@dragonfly1414
@dragonfly1414 5 жыл бұрын
Hello Mr. Gray my heater setting 75 but keep running to 90 and way to heat inside the house, any advise will be appreciated, thank you
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
Electric, gas or oil? GFM
@deborahshingleton2628
@deborahshingleton2628 6 жыл бұрын
that bottom part moved on its own did you see that?
@dcobhc
@dcobhc 7 жыл бұрын
Thank you for another great informative video!
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Welcome GFM
@craignehring
@craignehring 7 жыл бұрын
Say there GFM, what is a recommended cleaner for fan wheels? I imagine it depends on the type of filth collected?
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
I use an industrial cleaner made for coils and fans. However, a household grease cutter type cleaner will work well. GFM
@TheChug
@TheChug 5 жыл бұрын
Is there a limit switch in Electric + Heat Pump furnace? My furnace works on heat pump, but when it's too cold for the heat pump, it shoots cold air on Aux Heat... thanks!
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
There are limits on electric furnaces/air handlers. I would be looking for kicked off breakers or control problems. GFM
@TheChug
@TheChug 5 жыл бұрын
@@grayfurnaceman oh OK, breakers are OK. The damn air handler is in the attic... This morning it was blowing colder air than indoor temperature and when I switched it to EM Heat, it blowed air at roughly 68 degrees... I shut it all off and using the room rads now... I'll look to install a new unit inside the house. I think it was stupid to have it installed in the attic by the previous owner... Up here in Canada, it get real cold. Thanks for your quick answer.
@mazenblue3790
@mazenblue3790 6 жыл бұрын
Thanks for the video. I have an old Crane furnace and the fan belt blower motor never shuts off. It will stay on as the furnace heats up and not turn off at the end of the cycle. It's not the thermostat because I changed it out and the blower remained on. It has a honeywell limit switch like the one in this video and it is set to auto. Do you think the limit is bad? The temp relay clicks on and off when the fan is turned on, even though it's already running so I think the relay is good. Any advice would really help me out! Thanks
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
This sounds like the fan and limit has failed. Try hitting the ductwork near the fan and limit. If it shuts off, you are certain that is your problem. GFM
@mazenblue3790
@mazenblue3790 6 жыл бұрын
@@grayfurnaceman Thanks a lot, I'll give it a shot. Will hitting the ductwork reset the switch or something?
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
It breaks the contacts loose. GFM
@mazenblue3790
@mazenblue3790 6 жыл бұрын
@@grayfurnaceman thank you. It was a bad fan limit switch.
@1cleandude
@1cleandude 7 жыл бұрын
Thank you Mr. Gray I appreciate your videos and they are very helpful!! My Trane unit purges, ignites and then the blower comes on. After getting to the set temp the gas shuts off and the blower continues to run until manually disconnected. It would normally run for approx. 2 minutes as a post purge/cool down. Would a limiter cause the blower to continue running? The error light is 5 blinks however your Error code video did not elaborate on this particular code. Any suggestions? Thanks again!
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Its possible the unit has locked out on flame failure or a pressure switch problem. The 5 blink means the flame rod is sensing flame when there is no power to the gas valve. Are you sure its 5 blinks? If the flame goes off, it should not be sensing flame. GFM
@1cleandude
@1cleandude 7 жыл бұрын
Thanks for the reply; yes I just looked at the IFC and it blinks 5 times pauses and blinks 5 times etc. When the furnace is running I have 25 volts at the limiter. When the flame shuts off I have no voltage and the blower keeps running with the 5 blinks at the IFC! Could it be a stuck relay in the IFC; the unit is 10 years old. Thanks again! David
@tylersalisbury872
@tylersalisbury872 4 жыл бұрын
My electric heat air handler had it's sensors go off due to high heat but the filter was new and had enough air flow to it but the sensor kept randomly going off and had my neighbor come over and test the airflow and was correct.. we since replaced the heat strips because the relays stuck on and caught fire..
@grayfurnaceman
@grayfurnaceman 4 жыл бұрын
The shutdown was probably due to one of the sequencers (relays) sticking on and overheating the furnace which will result in limit switches opening. GFM
@brianlange9356
@brianlange9356 7 жыл бұрын
Hello GFM, Your videos and website have saved me service calls and money in the past and allowed me to become pretty comfortable at troubleshooting and working on my Goodman GMH80453ANCB. I truly thank you for that. I have a problem now that has me puzzled and sounds possibly like a limit switch issue that you describe here. I will attempt to provide some detail here. The heater comes on with the thermostat, the inducer cycles up, the pressure switch actuates, the ignitor glows, gas flows and the burner lites. (2 burners) The burners remain lit for about 15 seconds and the gas shuts off but the ignitor almost immediately begins to glow and the cycle repeats until the thermostat is satisfied. The problem is that the blower is almost constantly running through this cycle. This is causing the air being pushed to be luke warm if not just room temperature. Filter replaced and the symptom is the same with 2 control boards.(on hand for a previous problem) I have just replaced the limit switches for the heat ex-changer 220 degrees and the blower 120 degrees. I do not see any indication of a problem with the heat ex-changer such as off color or erratic flame, blow back from the fan etc. As I said, I am puzzled and about to call a pro as this is causing the heater to run almost constantly and not able to heat the house. Sorry to be so long winded.:)
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
I would try temporarily jumper the limit (and I do mean temporarily, do not under any circumstances leave the jumper on), If the problem stops, you may have a failed heat exchanger. The heat from the burner is contacting the limit directly. GFM
@brianlange9356
@brianlange9356 7 жыл бұрын
Thank you for the response. I jumped the 2 female spade connectors to the primary limit switch. The initial burn cycle lasted about a minute. I was able to run upstairs to check the air and it was obviously warmer. However it then returned to the previous cycle of the burn lasting only about 15 seconds. I do not remember exactly what a normal cycle was like, but I assume that even this last cycle while jumped would not be normal.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
I assume that with the jumper installed, you reverted back to the 15 seconds on condition. Have you jumped out the thermostat? GFM
@brianlange9356
@brianlange9356 7 жыл бұрын
No I have not. Just jumper the 2 wires?
@brianlange9356
@brianlange9356 7 жыл бұрын
I jumped the thermostat, while not exactly the same, it is still not normal. Burners lit following normal startup cycle. Burners ran about 30 secs, immediate ignitor glow, 6 sec burn, ignitor, 13 sec, ignitor, 12 sec, ignitor, 12 sec, ignitor, 9 sec, ignitor, 14 sec, ignitor and so on.
@leslielambert4500
@leslielambert4500 6 жыл бұрын
I have A criterion gas furnace blower will not shut off even from thermostat I have to replace the panel to shut it off no heat, but I did notice the batteries were dead in thermostat I change them
@leslielambert4500
@leslielambert4500 6 жыл бұрын
Anyone help or had this problem
@albotiger7268
@albotiger7268 6 жыл бұрын
If that’s the symptoms then it sounds like you have exactly this problem same problem with the High Limit switch. If the fan has run for a long time and it doesn’t reset then your switch inside is probably a manual reset and should have a button you can push in which would close the switch and bring the heat back on
@defiantlion231
@defiantlion231 6 жыл бұрын
Could loose screws on the fan grill cause problems? I found a few screws loose laying just b-low the back burners & 1 n the front. Could a wire possibly be connected to say a screw?
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
It certainly could. Depends on where they came from. If you send me pics of the screws I may be able to tell you if you should be worried. Send to Grayfurnaceman@gmail.com GFM
@yamilrodriguez5918
@yamilrodriguez5918 5 жыл бұрын
I am trying to run the blower ON with the furnace OFF(Luxaire TM9V) to move the air around the house but it will not work. It only work on the auto possition with the furnace working. Any ideas how i can fix it.
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
Have you shut off the power to the furnace? The fan will not work with the power off. If your furnace is on and the fan, when set to "on" will not operate, the "G" terminal at the furnace is not connected to the "G" terminal of the thermostat. GFM
@yamilrodriguez5918
@yamilrodriguez5918 5 жыл бұрын
Thank you for your reply. I will check the G terminal connection tomorrow. Power is OK. The furnace is working and fan works with it. Just trying to operate the fan manually to circulate the air on the house.
@yamilrodriguez5918
@yamilrodriguez5918 5 жыл бұрын
@@grayfurnaceman Hi GFM checked the G terminal at the furnace and it is a green wire and at the thermostat is the same. At thermostat(White Rodgers model#1F78) W- white, RH-black, RC-red, G- green, Y-orange .
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
@@yamilrodriguez5918 Jumper from "G" to "R" at the furnace. If the fan works jumper "G" to "R" at the thermostat. If it works, it is the thermostat. GFM
@yamilrodriguez5918
@yamilrodriguez5918 5 жыл бұрын
@@grayfurnaceman Hi GFM tried the jumper. No luck. after checking the schematics of the furnace looks like the power to the fan is controlled buy the ignition sensor. No ignition no power. i guess it is the design in this 2 stage furnace. I will look if i can bypass it running power directly to th fan wit a switch on the outside. But that will be on the summer time. Thank you for the help.
@justincuevas8529
@justincuevas8529 6 жыл бұрын
My issues is with a furnace that’s blower stays on during auto without calling for heat. It gives an error code for the flame rollout but instead of just buying the rollout what can I do to either bypass the rollouts or make sure that is the problem?
@vn8410
@vn8410 4 жыл бұрын
I measured continuity for this device 5'' old style and figured out that is bad. Ordered from amazon new one 5" with fan button and connected, my thermostat was off/heat was off, when I turned power on blower motor started working and heat come up, gas valve energized and something started melting. What was wrong why it used to do like that? All wires were connected properly.(((
@grayfurnaceman
@grayfurnaceman 4 жыл бұрын
Beats me. Sounds like you wired it wrong. GFM
@sotog1217
@sotog1217 5 жыл бұрын
have a carrier 58SX100-cc sometimes just here inducer motor running so i look in the little window by burners no pilot if i disconnect hose from presure switch and blow through hose into furnace it will light and work any idea
@1lefty123
@1lefty123 5 жыл бұрын
Anyone in the business uses low to medium restricting filters and change them faithfully. High restrictive filters strain the blower and put you at risk for high limit trips.
@themancmt
@themancmt 6 жыл бұрын
Couldnt you just bypass the switch all together by hooking up the 2 wires together that go strait to the switch?
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
Yes, for testing only. However, leaving the jumper installed will result in dangerous overheat of the furnace. GFM
@msj103105
@msj103105 7 жыл бұрын
Good Day I have a furnace that the exhaust fan and blower motor come on, when a call for heat is initiated. I also get a code for pressure switch error. Why would the exhaust and blower come on at the same time Thank you
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
It may be because of the failure code. Some furnaces turn on those fans to let you know there is a problem. GFM
@msj103105
@msj103105 7 жыл бұрын
grayfurnaceman thanks For the quick reply, gonna replace the PS its to be faulty, after jumping it out it worked. thanks i always learn from your vids
@FTGxSoJuFoRcEs
@FTGxSoJuFoRcEs 6 жыл бұрын
Thanks Hank Hill 😎
@mumenrider862
@mumenrider862 5 жыл бұрын
if it's a goodman, the board is probably bad. If you check the limits and they're good, replace the board with an updated one.
@joyful4350
@joyful4350 6 жыл бұрын
Hello Sir, I just had a blower motor replaced on a 7 year old Carrier 95, but limit switch error code (4 blinking lights)still comes on and burners shut down only to come back on when furnace cools down. Filters fine. Blower fans clean. Could it just be a faulty limit switch or is there something else I should be making sure my HVAC tech should be checking? Thank you
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
You probably have an air flow problem. Secondary heat exchanger plugged. A/C coil plugged. GFM
@sergeihanush2262
@sergeihanush2262 2 жыл бұрын
I have Westinghouse/Nordyne fg6ra 096c-16b furnace. And my blower could randomly turn on between heat cycles with inducer on together. When i come to the board and see red led light it is constantly blinking. Error coded state that in this situation it is false flame (flame sensor was just replaced) OR Gas Valve relay shorter. I didn't replace yet gas valve because i can't convince myself that problem is actually in gas valve. If someone could help me convince myself that shorted gas valve relay could cause inducer and fan run together randomly between heat cycles? Thank you
@grayfurnaceman
@grayfurnaceman 2 жыл бұрын
A shorted gas valve relay could not, but a failed control board could. GFM
@sergeihanush2262
@sergeihanush2262 2 жыл бұрын
@@grayfurnaceman Thank you. That is my suspect at this moment as well
@garyduran1
@garyduran1 7 жыл бұрын
When the thermostat is off(no call for heat) I hear a fan come on, then off, then on? When i do call for heat everything works fine? Can you help me? thank you
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
If the unit has a heat operated fan switch, the on and off temps may be too close. If you set them farther apart, it could stop the problem. GFM
@garyduran1
@garyduran1 7 жыл бұрын
Thank you sir, no heat operated fan switch on this unit. In the wee hours of the morning I can hear the little fan turn on, as if I am calling for heat, but then turns off, then on then off? And it does this when the thermostat is on auto and off. Day and night L.P. model 376CAV036075. Is it possible its scencing a propane leak and turns on to clear? I am baffled. Thanks again.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Not a propane problem. That sounds like a thermostat problem. Try bypassing it. GFM
@garyduran1
@garyduran1 7 жыл бұрын
I am just a DIY.. I am not familiar with GFM. I did replace thermostat a few weeks ago with a cheap honeywell one.. maybe i need a better one? thank you.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
GFM is short for Grayfurnaceman. If you remove the wires from the thermostat, and and it does not come on at night, the thermostat is the problem. GFM
@MegaWhitesox05
@MegaWhitesox05 7 жыл бұрын
old 16 year old tempstar when you first start it shuts off then you started 3 more times then its starts running normal is it the gas valve?
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
MegaWhitesox05 From what you say I would be looking to clean the flame rod. GFM
@MegaWhitesox05
@MegaWhitesox05 7 жыл бұрын
it was changed its new it still does the same thing.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Have you tried bypassing the thermostat? GFM
@MegaWhitesox05
@MegaWhitesox05 7 жыл бұрын
no but i will try it thanks
@pixelbat
@pixelbat 6 жыл бұрын
Heat stopped working in my Carrier furnace today. Been trying to figure out what's wrong. My blower runs when I turn it to heat for about a minute, then turns off. Only cold air comes out. The draft inducer is pretty noisy, and I suspect something is wrong at that point in the chain, because it doesn't get to the igniter glowing. I know the igniter works tho, because I ran it through the test cycle by shorting the test terminal with 24v Com and it light up during the test. Any ideas? Would the chain stop if the draft inducer was weak or not working properly? My LED codes are totally normal. Any advise is appreciated! Thanks
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
I would be looking at pressure switch problems. If you jumper the pressure switch during a trial for ignition, does it come on? GFM
@pixelbat
@pixelbat 6 жыл бұрын
Thank you so much for the advise. I figured it out. It was the draft inducer motor. It was seizing up. I gave it some turns and it started to work again, and everything kicked on. Ordered replacement, so I'm pretty confident that motor is literally on it's last leg. I'm just happy to have heat again. Still cold here in Michigan.
@solarsynapse
@solarsynapse 6 жыл бұрын
My blower fan randomly comes on and runs for a short time and then goes off with no call for heat.
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
Can you give me an approximate age of the furnace? GFM
@solarsynapse
@solarsynapse 6 жыл бұрын
Not sure. 2002? It is a Coleman DGAT075BDF that was used a couple of seasons and then sat for years. The mobile home was scrapped and the furnace installed into a 1986 mobile home fall of 2017. For grins I cleaned the flame sensor rod and replaced the board with one from a known working unit. Same thing. My next guess is one or both of the temp switches. Sometimes when it cycles from a call for heat the flame goes out when the blower comes on and then it recycles and works. Haunted.
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
Could be the whole house fan is coming on. Mobiles of that age do have a fan to bring in outside air periodically. GFM
@solarsynapse
@solarsynapse 6 жыл бұрын
Wow, never thought of that. Learn something new every day.
@lorrainenunnelley2853
@lorrainenunnelley2853 6 жыл бұрын
My fan is just running all the time, in the off position and on auto as well, gas furnace. Also my a/c is broken. With a 4 year old this is so frustrating..
@grayfurnaceman
@grayfurnaceman 6 жыл бұрын
A gas furnace will turn on the fan to alert the homeowner that there is a failure in the furnace. Have you checked the error code? There is a light that will blink a code viewed thru a small window in the furnace cover. The key to the code is usually on the inside of one of the covers GFM
@alisaad-oj9oq
@alisaad-oj9oq 6 жыл бұрын
Lori Nunnelley is
@speed5763
@speed5763 7 жыл бұрын
you need to do one about the right filter good -better -best TOO thick --less air flow -- MORE PROBLEMS .... I WANT THE BEST---but my 15 year old oil furnace is not getting enough air ---FAN is always running
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
I have a series in mind and will be getting it out there hopefully soon. GFM
@MrWaseskwan
@MrWaseskwan 4 жыл бұрын
My whirrlyball was on
@cavibird2005
@cavibird2005 7 жыл бұрын
Secondary HE Externally or internally plugged up.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
That could certainly cause it. Thanks for the thoughts. GFM
@adambrecker2600
@adambrecker2600 7 жыл бұрын
my furnace fan blows air and no heat also I hear a clicking noise a lot do you know what that noise is??? Thanks.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
Gas furnace? GFM
@adambrecker2600
@adambrecker2600 7 жыл бұрын
It's a Beckett oil burner
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
I am not sure what the noise is but your burner has probably shut down on flame safety. GFM
@adambrecker2600
@adambrecker2600 7 жыл бұрын
grayfurnaceman I also pulled out the fuel nozzle electrode mechanism it was all black.
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
It is normal for the gun assembly to be black from extended use. That does not mean the nozzle is not plugged. When the gun is removed, the assembly should be cleaned and the nozzle should be replaced. GFM
@x.y.8581
@x.y.8581 7 жыл бұрын
How do you set the old style (one on left in video) limit switch?
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
I have a video on that. kzbin.info/www/bejne/h6Grl3maoJVnq5I GFM
@antoniokristler6973
@antoniokristler6973 7 жыл бұрын
Cracked heat exchangers build up heat. Plugged evap coils from sweaty pet hair/dirt/drywall dust. For the love of god if its over 13 check that exchanger, if its a 90 percent unit remove the inducer motor and check for rust by the blower. Plugged secondaries can happen even at 12 years.
@bigking1954
@bigking1954 6 жыл бұрын
Antonio Kristler how to install a switch with a Buss fuse on it to a furnace show how to install a switch with a Buss fuse in it for a furnace
@edbtzkhud
@edbtzkhud 7 жыл бұрын
99.9 percent of the time it’s a control board. I’ve seen filters that haven’t been changed in more than two years and didn’t have this symptom. Just google the model number pick your part and replace!
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
that has not been my experience. A continuously running fan could be a stuck limit, rollout switch open, flame failure, or pressure switch problems. The IFC is the absolute last part I would replace. GFM
@Chiwawaleg
@Chiwawaleg 7 жыл бұрын
edbtzkhud youre an idiot
@bobheck7303
@bobheck7303 6 жыл бұрын
I agree with leg!
@jaybeecee1949
@jaybeecee1949 6 жыл бұрын
Who the hell keeps their house at 73 degrees? Put on a sweater!
@ramonaburns605
@ramonaburns605 5 жыл бұрын
brainmatterz screw that mine stays at 75
Top 5 Furnace Problems and How to Fix Them
20:07
Word of Advice TV
Рет қаралды 1,6 МЛН
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН
We Attempted The Impossible 😱
00:54
Topper Guild
Рет қаралды 56 МЛН
Quando eu quero Sushi (sem desperdiçar) 🍣
00:26
Los Wagners
Рет қаралды 15 МЛН
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 2,3 МЛН
Indoor Fan Keeps Running - 10 Reasons Why
20:19
Word of Advice TV
Рет қаралды 587 М.
New Construction HVAC Hack Job Butcher Sabotage pathetic installers
21:38
New Idea For Vevor Diesel Heater ??
20:47
Rickards Garage
Рет қаралды 252 М.
A Simple Trick To See If Your Heat Exchanger Is Cracked.
11:56
The DIY HVAC Guy
Рет қаралды 460 М.
How To Repair Electric Central Heating System(No Heat)
19:24
electronicsNmore
Рет қаралды 357 М.
Furnace Fan Won't Stop Running! Thermostat Off
7:48
Apartment Maintenance Pro
Рет қаралды 12 М.
The Most Common Reason Why A Gas Furnace Won't Turn On
8:25
Everyday Home Repairs
Рет қаралды 2 МЛН
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН