Пікірлер
@KimberleyJensen
@KimberleyJensen Күн бұрын
Dinosaur UIB 624 board?
@MyRVWorks
@MyRVWorks Күн бұрын
Dino UIB64 amzn.to/3OswYrp
@DanielButterfield-q7n
@DanielButterfield-q7n Күн бұрын
😂thank you
@soonermadden
@soonermadden Күн бұрын
Best video for the DIY guy!!!! Well done sir!
@tammieeakins3060
@tammieeakins3060 Күн бұрын
Currently have my water heater out to replace the water connections, and looking at all this as I have it out. So much detail and what a great video! I also learned some good info at store about PEX connections. But after watching a video that didn't show detail like this, I was about to spend more money than necessary. Thankfully another shopper showed me a better solution, and less expensive. The PEX crimper is very expensive tool for a 1 time use. Hopefully I will have your water tomorrow for Thanksgiving day! Thank you again. Anxious to watch your other videos!
@MyRVWorks
@MyRVWorks Күн бұрын
For all those different Plumbing connections, here's a video we put out demonstrating some options you may find useful. kzbin.info/www/bejne/nIbOdnenodx2l9Esi=Llf298JMOO0g1hBD
@dmitriichubich8552
@dmitriichubich8552 Күн бұрын
Thank you for such detailed explanations. Please tell me, I have a problem and I can't understand what the reason is, my thermostat from Coleman has a relay and when I turn on the heater this relay clicks 2 times and sometimes it happens that it clicks 1 time the heater starts up and heats up and then clicks again and stops and works randomly, I tried to install a new thermostat but it didn't help me, the heater is in perfect condition it is 100% working and was tested with different components
@javacup912
@javacup912 2 күн бұрын
Amazing how a leaky pop off valve, caused so much, but like you say, a neglected water heater. Just going through this on my recent purchase of a travel trailer, which during the back flush a lot of calcium material came out, and because the anode rod was almost at the wire, I'll have to check more things. Thanks for the video. Learned more.
@javacup912
@javacup912 2 күн бұрын
Great video for sure. Really awesome. Just got a new for me, 2006 travel trailer where the water heater LP works, and DC, but have not verified not working on A/C, so this is a great start. Thank you.
@part-timephilosopherLol
@part-timephilosopherLol 2 күн бұрын
Love this video so much .. have been reviewing for last couple of months with exploded view of parts you mention for that make/model/serial - ok so you mention the big orange wire that acts first as a source of arc or like a spark plug but then becomes a source of milliamps through the gap of the electrode .. how does it know to do this? what is the mechanism? I am super keen person who hopes to be an apprentice, even at 55!!
@capnsandy974
@capnsandy974 2 күн бұрын
Thanks so much!!
@RayPerkins-h1v
@RayPerkins-h1v 2 күн бұрын
Acetone dissolves sprayfoam.
@DennisBrazil-o4e
@DennisBrazil-o4e 3 күн бұрын
I installed T on Main propane tank to add extra tank and stove and water heater work, but not furnace. Could it be that main tank reads empty?
@MGarage2816
@MGarage2816 3 күн бұрын
So what happens when the furnace kicks on but no heat. Blower works
@healsinger
@healsinger 3 күн бұрын
This is great detailed info for a first timer working on a furnace. Thank you for your generosity.
@ss0073
@ss0073 3 күн бұрын
Thumbs up from me pal! Same burner model, same issues, same problem when I took it apart. No BS video....finally!
@Fifty1Romeo
@Fifty1Romeo 3 күн бұрын
It's called a brake hub. FYI
@edmills9661
@edmills9661 3 күн бұрын
Thank you for the informative video. Made my job easier.
@chicomontecristimusic
@chicomontecristimusic 3 күн бұрын
The part where you disconnect the solenoid wires at 18:00 is a major point of instruction. If watching, please make sure your wires are connected properly. Mine were not and as soon as I matched my wires to your video my LP SPARKED! THANK YOU! God bless.
@TheBay-59
@TheBay-59 4 күн бұрын
But what are you connecting it too?? Should have showed us first.
@WandaYoungsBailbond
@WandaYoungsBailbond 4 күн бұрын
We certainly plan to utilize your expertise on our Newmar Oasis system
@JoseeMorissette-w5f
@JoseeMorissette-w5f 4 күн бұрын
Great job, this video will make mine a lot easier.
@MGarage2816
@MGarage2816 4 күн бұрын
Okay so we have a suburb Sf 35 I replaced the electrode/igniter thing and I have replaced the limit switch. Wasn’t able to get heat. Well I than replaced the circuit board and now it’s engaging like it wants to lite however, I am smelling gas from the exhaust tube and nothing happens. It doesn’t ignite.
@gregwall944
@gregwall944 4 күн бұрын
Nicely done! Thank you
@markvogt9462
@markvogt9462 4 күн бұрын
I agree with the comments below stating this is the best video I've come across on water heaters. Your an excellent trainer, my guy! Kudos!
@langr752
@langr752 5 күн бұрын
I’ll let the ohm analogy go…. But calling your wife a “one” and you a “five”….. man what are you doing with your life? Tisk tisk😂😂😂
@ToniaSmith-i8w
@ToniaSmith-i8w 5 күн бұрын
I need to know how to get that part out of the metal box?
@cruze1953
@cruze1953 5 күн бұрын
Furnaces don't just output CO2 they also output CO, HC and NO depending on the air-fuel ratio. Industrial furnaces. IC engines and boilers have catalytic converters on them. I tune them to 6000ppm CO and 700ppm NO. Post catalytic converter is 72ppm CO and 1 ppm NO. I set the gas pressure using the regulator just like on an RV. For high elevation you can re-jet it or lower the fuel pressure.
@cruze1953
@cruze1953 5 күн бұрын
Hi Darren. If a sail switch works properly on start-up but intermittantly opens from varying airflow does the furnace immediately fail or is there a time-out delay (such as one or two seconds) before the air/limit fault trips? An example of airflow deviation would be from reduced CFM from a voltage drop from a high current device elsewhere.
@billborman4929
@billborman4929 5 күн бұрын
Thank you! This video and test was exactly what I needed to make the $ decision to replace my "blocked" Norcold NA10LX cooling unit that I found with choked ventilation. I also went with CoolFunRV you recommended. They work core exchanges and were the least expensive option I could find in the US. I did have a problem with the initial start of the CoolFunRV unit not working at all and freezing up on the return lines to the tank. Note that CoolFunRV does not reply to emails (at all), but after a phone call and quick call back from their technician Sal, I learned that the unit was "back cooling" due to the unit not settling completely after shipment. After a little shaking and a restart, the fridge was down to 35°F in about 6 hours. Yay! Thank You again for this great channel.
@johncasor9698
@johncasor9698 5 күн бұрын
12 volt battery has 6 plates at 2.11 volts each ... which is 12.66 volts... just say`n
@tomgeving2445
@tomgeving2445 5 күн бұрын
I need to change my pumps but I can’t pinch off the hoses. Am I going to have trouble.
@harleyschlabach7635
@harleyschlabach7635 5 күн бұрын
Thanks for this detailed video was a great help to me! This exact thing was happening to my coach. Aqua hot was working fine but heat zones were blowing cold air. Now I can go test it. Thanks again
@danthurber2772
@danthurber2772 6 күн бұрын
Nice, thanks for going into the weeds a bit. I could have definitely kept watching you go on and on for another hour. Maybe that would help me figure out why the fridge keeps running too cold and freezing the top two shelves even with the thermistor slid all the way to the bottom.
@joeseiller2478
@joeseiller2478 6 күн бұрын
Hi, I was just wondering about what you would charge for a hot water heater service. I realize that you can't do it yourself, because I live in Bowling Green, Missouri. But I have a trailer with a Atwood in it, just like the one that you serviced in this video. Thanks for the awesome info. Joe 😊
@saladbreath607
@saladbreath607 6 күн бұрын
Aye, sir. Wonderful, articulate, no nonsense video. Similar symptoms and burner condition. The electrodes were touching the burner just like yours. I started to bend it gently and it snapped off, so two parts on order! Looking forward to a warm winter.
@Outdoorjunkie246
@Outdoorjunkie246 6 күн бұрын
Brake drum
@johncasor9698
@johncasor9698 7 күн бұрын
i have same thing, my dual switch is in the front of the unit where i can stand and see what the hell i am doing. unlike you... owner should demand you change it right now...
@infamousS709
@infamousS709 7 күн бұрын
Thank you! The close up really helped along with the tricks!
@ericrainey5361
@ericrainey5361 8 күн бұрын
I have a 1984 Norcold Electronics 838EG3. Can I run it just by 12DC and not use propane?
@ericrainey5361
@ericrainey5361 8 күн бұрын
I have a 1984 Norcold Electronics 838EG3. Can I run it just by 12DC and not use propane?
@ALLaboutGAMINGxCHAOSxHOLLOWx
@ALLaboutGAMINGxCHAOSxHOLLOWx 8 күн бұрын
hey buddy would you happen to know the part number to the motor its self?
@AnnaTemple-f5u
@AnnaTemple-f5u 8 күн бұрын
Yes thank you
@kentrichardson9070
@kentrichardson9070 8 күн бұрын
One of the best and informative videos I’ve seen. More inspection and regulations need to be enforced at manufacturing. Cheers
@christinewoodard6865
@christinewoodard6865 8 күн бұрын
Can you put bigger fuses where 15 is
@derensd
@derensd 8 күн бұрын
Awesome video, you're very good at teaching!! thx for sharing with the world!!
@s.mendez7160
@s.mendez7160 8 күн бұрын
You have a gift as a teacher. These videos are incredibly helpful. Was wondering if the vertical axis placement of the thermistor on the fin also applies to other Norcold fridges like the N82X series? Thank you again.
@mikekeilman7813
@mikekeilman7813 8 күн бұрын
Great Video!!! I learned much!!!
@sergeoliva5537
@sergeoliva5537 9 күн бұрын
My drive collet popped up and I can not re engage it
@MyRVWorks
@MyRVWorks 9 күн бұрын
I talked about that in several videos on how to recover. The most recent video we did on the Schwintek I do talk about it as well. Here's a link to that video: kzbin.info/www/bejne/bYbaf2mMm9Kagrs&si=36EWsIpcsw7_qEUC
@charlesknapp4079
@charlesknapp4079 9 күн бұрын
Hi there, This video led me to replace my control board as I was not getting power out of the board to the gas valve and the ignitor. After replacing the board I now get spark and the gas lights but goes off after 6-10 seconds. I replaced the ignitor but still have the same issue. It is a Atwood GC6AA-10E. What should I check next?
@wt7846
@wt7846 9 күн бұрын
5 years later and this video definitely cleared up some confusion on how it actually works and confirmed for me how it should be wired. Thank you sir!
@jono2655
@jono2655 10 күн бұрын
I would recommend putting Pipe Tape for Gas (yellow) on the fittings to prevent leaks.
@MyRVWorks
@MyRVWorks 9 күн бұрын
That's correct for NPT threads (never the first two threads though). But you never, ever, ever, never, never, never, never, ever, ever put Teflon (tape or paste) on a flare fitting. If the flare is properly swedging itself that is your gas tight connection.