Carrier RTU 8.5 Ton Not Turning On Affecting The Weight Room… It’s Getting Hot

  Рет қаралды 6,902

Subcool HVAC

Subcool HVAC

Күн бұрын

Got a work order for AC down in the mini gym weight room, temperature rising and not turning on #hvac #airconditioning #carrier

Пікірлер: 36
@ericbaker5619
@ericbaker5619 17 күн бұрын
A bypassed VFD on a carrier? No way! I swear their VFD quality is terrible past few years
@subcoolHVAC
@subcoolHVAC 17 күн бұрын
Lol, I guess 1 out of 6 isn’t too bad 😂
@MarcosHVAC
@MarcosHVAC 17 күн бұрын
I have a site with 32 carriers all 25 tons from 2020. We call it the Covid building. Numerous issues from factory that I caught on start up. Watch out for those insulated terminals for the drive. I had a few burn out on me this spring
@subcoolHVAC
@subcoolHVAC 17 күн бұрын
Oh man, good to know . Thanks Marcos 👍
@ccthepope
@ccthepope 18 күн бұрын
Great video! (as always)
@subcoolHVAC
@subcoolHVAC 18 күн бұрын
Thanks CC 👍
@stevencossaboon3237
@stevencossaboon3237 17 күн бұрын
Nice troubleshooting and video Subcool.
@subcoolHVAC
@subcoolHVAC 17 күн бұрын
Thanks Steven !!
@jrsmyth9761
@jrsmyth9761 17 күн бұрын
Carrier does have a service/tech bulletin on how to wire around the VFD. This unit appears to be cool only so low voltage control wiring you did should be okay. However, there is already a signal wire in the unit for this purpose, well it is there if there was no VFD. Also, I did not see that the wires ran through the fuses that are in the blower compartment. Maybe it is different on 460VAC, I don't think I have worked on anything over 240VAC that I bypassed the VFD on. The fuses are supposed to still be used but need to be changed to a different type. I usually run the yellow wires that are on the capacitor for the condenser fan motor directly to the contactor instead of to the capacitor. Just my OCD/thing to do.
@subcoolHVAC
@subcoolHVAC 17 күн бұрын
I didn’t see fuses for the blower , the cfm relay is the weak link to the motors , the yellow motor leads remain energized through the cap common. They already have enough wires shoved into undersized contactors as it is 😂 Thanks for commenting
@jrsmyth9761
@jrsmyth9761 17 күн бұрын
@@subcoolHVAC I run the yellows to the same side of the contactor as the common/yellow wire to capacitor is run from. If there is too much on there, they are not long enough or it is just easier then they stay on the capacitor. As for the fuses,, there is a block for them just above the VFD, at least on the units I have worked on. Again, maybe different on the higher voltage equipment.
@maheradous9257
@maheradous9257 16 күн бұрын
Good job 👍
@subcoolHVAC
@subcoolHVAC 15 күн бұрын
Thanks 👍
@marcelocortez18
@marcelocortez18 17 күн бұрын
Have have some really good content, u should consider gettin a tripod to show yr work/installations, I think that would be cool to see. Keep up the cool videos
@subcoolHVAC
@subcoolHVAC 17 күн бұрын
Thanks, the tripod would slow me down, I just try to film as I go and get the repair done as efficiently as possible. I appreciate your input 👍
@marcelocortez18
@marcelocortez18 17 күн бұрын
@subcoolHVAC yea I understand
@jasonjohnsonHVAC
@jasonjohnsonHVAC 13 күн бұрын
Great video
@subcoolHVAC
@subcoolHVAC 12 күн бұрын
Thanks Jason 😎
@robmcshane3260
@robmcshane3260 17 күн бұрын
Don’t you love where the vfd is mounted. F carrier!!
@subcoolHVAC
@subcoolHVAC 17 күн бұрын
It’s genius 🤣
@c21meister
@c21meister 15 күн бұрын
@@robmcshane3260 right in the airstream with all the moisture
@subcoolHVAC
@subcoolHVAC 15 күн бұрын
You know it 👍
@c21meister
@c21meister 16 күн бұрын
Waiting on a vfd now for a carrier
@subcoolHVAC
@subcoolHVAC 16 күн бұрын
😔we do a lot of waiting
@Josh.SPublishingTeam2024I
@Josh.SPublishingTeam2024I 18 күн бұрын
Hi, i am a new subscriber nice trobleshooting, the wire was crisp
@subcoolHVAC
@subcoolHVAC 18 күн бұрын
Welcome to the channel 👍 yep, it was a little over cooked !
@johnpadua9115
@johnpadua9115 17 күн бұрын
Looks like the sheaves opened up and motor over amped
@subcoolHVAC
@subcoolHVAC 17 күн бұрын
Set screw was loose but didn’t look like it spun, I was thinking loose wire nut at motor possibly. 🤔
@caffeinatedinsanity2324
@caffeinatedinsanity2324 15 күн бұрын
Not really an hvac tech myself but mostly working on building automation projects yet I also do some service calls from a distance from my office to figure out what is going on. Fishing for information when dealing with problems is always a fun game. Steps I undertake: -Open the BMS and if there are GUIs created for the sector, open them and do a quick scan on the rooms of the building. Afterwards, narrow down the issue. Usually, i have dealt with lack of cooling on hot summer days, as opposed to the lack of heating during winter, for some reasons. Most of times they were RTUs feeding cool air to VAV damper boxes. The first thing I always notice is that all rooms fed by the same system are at least 2-3 °C above their setpoint (usually around 21-22°C), even if the customer tells you only a few are problematic (ex: 27°C, which is really hot). Either they genuinely had a mechanical problem that needed to be fixed, or sometimes it's just a case of undersized unit. If you see that the unit fails to maintain duct static pressure even when the fan is at 100% speed (because the room controls are all at maximum cooling demand and therefore, maximum airflow) or if all compressors are on and recently maintained but the air is still above 20°C, you can tell right away that the unit is undersized for the building's requirements. Sometimes I stumble upon autonomous units integrated on the BMS's BACnet network that generally give a lot of info, sometime I stumble across ones where we put our electronics on to control them and the equipments have feedbacks for a bunch of stuff (ex a current transducer on the power lines of the blower, compressor, etc...), and sometimes no feedbacks on the real state of equipments, mostly older installations. I have limited skills when it comes to troubleshooting machines physically, but whenever I can, I go fish for info for my colleagues who might be dispatched there.
@subcoolHVAC
@subcoolHVAC 15 күн бұрын
Thanks for commenting, hopefully you found this call interesting
@Attest411
@Attest411 17 күн бұрын
Just enough information so you can out source the motor
@subcoolHVAC
@subcoolHVAC 17 күн бұрын
Yep, motor volts/amps and frame 👍
@abdullah_q8171
@abdullah_q8171 16 күн бұрын
Motor 3 hp
@subcoolHVAC
@subcoolHVAC 16 күн бұрын
Yes , that’s what we installed
@SombraLocs
@SombraLocs 14 күн бұрын
Those Carriers are junk!
@subcoolHVAC
@subcoolHVAC 14 күн бұрын
Willis wouldn’t be proud 🥲
Carrier RTU Start-Up From Hell
34:43
HVACR Survival
Рет қаралды 14 М.
I Can't Believe We Did This...
00:38
Stokes Twins
Рет қаралды 121 МЛН
WHAT’S THAT?
00:27
Natan por Aí
Рет қаралды 12 МЛН
Red❤️+Green💚=
00:38
ISSEI / いっせい
Рет қаралды 75 МЛН
ОСКАР vs БАДАБУМЧИК БОЙ!  УВЕЗЛИ на СКОРОЙ!
13:45
Бадабумчик
Рет қаралды 6 МЛН
😡 Newer Carrier RTU No Cooling.😩 💩
17:19
Michigan Heating Guy
Рет қаралды 6 М.
You're wasting money on heating! Use your A/C!
17:11
Tech Ingredients
Рет қаралды 390 М.
Mr S. teaching HVAC fundamentals.
20:35
Harman House
Рет қаралды 18 М.
THIS TRANE SPACESHIP JUST STOPPED WORKING
25:51
HVACR VIDEOS
Рет қаралды 46 М.
HVAC Installation Team
16:05
AC Plus Heating & Cooling
Рет қаралды 9 М.
Short Pro tool AC Diagnostic troubleshooting
18:59
Anti DIY HVAC
Рет қаралды 18 М.
There just ain’t NO WAY | HVAC |  Amana heat pump low on refrigerant
20:10
Koolin’ with Krauss HVAC
Рет қаралды 6 М.
Carrier rtu AC not cooling
18:08
Curious HVAC Guy
Рет қаралды 19 М.
He wasn’t ready … birthday celebrations continue!
0:17
The CrunchBros
Рет қаралды 20 МЛН
Best Father #katebrush #shorts
0:17
Kate Brush
Рет қаралды 31 МЛН
Best Father #katebrush #shorts
0:17
Kate Brush
Рет қаралды 31 МЛН
Вот так и помогай людям … #корейскоекафе #корейцы
0:19
CHICKO — Вкус Кореи
Рет қаралды 3,9 МЛН
Cool Items! New Gadgets, Smart Appliances 🌟 By 123 GO! House
0:18
123 GO! HOUSE
Рет қаралды 16 МЛН
Waka waka #2 🤣 #shorts
0:15
Adani Family
Рет қаралды 24 МЛН