How Many Outlets On One Breaker & Room By Room Circuit Layout

  Рет қаралды 1,231,945

Benjamin Sahlstrom

Benjamin Sahlstrom

Күн бұрын

Пікірлер: 1 100
@ladykenja2700
@ladykenja2700 6 жыл бұрын
- Ben, you appear quite young. Your level of knowledge & ability to "convey information in a meaningful way (to teach)" is truly appreciated.
@CASH-TO-THE-MERE101
@CASH-TO-THE-MERE101 5 жыл бұрын
lady kenja 👍👍👍, we need to👑👑👑 him...
@V3VoVo
@V3VoVo 2 жыл бұрын
He is 38 now. He just looks young.
@jurnagin
@jurnagin 4 жыл бұрын
That's the good thing about doing your own wiring, you can put them exactly where you want too! Makes owning a home more enjoyable when you know how it all works!
@deepsquat600
@deepsquat600 7 жыл бұрын
awesome job adding many many receptacles ..I have had 2 friends over the years build houses and I told each of them to make sure that you have at least one per wall and twice as often as code wants .. NONE of them regretted adding ( almost double ) the number that pans called for ( especially one guy was wiring most himself and had extra boxes ) again..good job!
@themonkeydrunken
@themonkeydrunken 3 жыл бұрын
Casually showing off that super-organized panel. Can't fault you for that. That's first-class workmanship
@lordrichard8184
@lordrichard8184 6 жыл бұрын
The nice thing about having your lights and outlets on different breakers is you can always see what you’re working on. You can run the lights while the outlets are off. And you can plug in a work light while your lights are off
@mrlovemuscleable
@mrlovemuscleable 6 жыл бұрын
Billy bob Smith You are right, in most of my electrical installations done in residential and commercial in accordance with IEE regulation, lighting circuit is separate from power circuit for many factors. I have seen here in the US how many residential homes are being wired with both lights and power in the same circuit, while it is true that it is less expensive and require less material run, I believe that inductive loads should not be on the same circuit as lighting. I have questioned experience licensed and master electrician and the gave the reason that it is cheaper and in accordance with NEC. While I will not disapprove NEC, separating circuits is important. In the video again, the guy mentioned about having smoke detectors and lighting circuit on the same breaker. I disapprove, these two should be separate because smoke detectors are essential emergency circuits.
@erlycuyler
@erlycuyler 6 жыл бұрын
My thought process exactly.
@ronb6182
@ronb6182 5 жыл бұрын
My dad always did it that way. Lights on a separate fuse or breaker now, he used fuses back in the fifties. Breakers were used in the farmhouse remodel back in the seventies. Never had a failed inspection. It's the shortcuts that contractors take that causes hazzards. I counted 14 recipticals on one circuit when I was updating electrical. I just wanted to add a wall switch for the fan light in the living room ended up breaking off a few recepticals onto a separate breaker. With led bulbs in the picture I cannot see why all overhead lighting be on one breaker now or two if you have a larger house.
@Apollyon1111
@Apollyon1111 5 жыл бұрын
mrlovemuscleable you may already know this, but smoke detectors on a lighting circuit because if they are on their own circuit and the breaker trips, the homeowner won’t know. If the lights don’t work, someone will look into it.
@ronb6182
@ronb6182 5 жыл бұрын
Why not have dedicated circuits for emergency type of loads. Smoke detectors, emergency lighting, fire alarms and security devices. Then you can put a safety breaker in the panel with no tamper locks on the breaker. The breaker will trip if needed but you cannot turn that breaker off.
@chrisb7551
@chrisb7551 4 жыл бұрын
Most importantly, when will all the weed plants be ready for harvest?
@jeffmoore6917
@jeffmoore6917 4 жыл бұрын
LMAO.....gottem
@Carl-ek4oe
@Carl-ek4oe 4 жыл бұрын
😂
@enochknock916
@enochknock916 4 жыл бұрын
First frost, 30 deg F.
@dk.650
@dk.650 4 жыл бұрын
😂😂😂
@ricktipton9563
@ricktipton9563 3 жыл бұрын
Haha.
@MrGeorgeTBone
@MrGeorgeTBone 7 жыл бұрын
There are two really good tips in this video. One was to put the smoke detectors on the same circuit as a frequently used light. The other was the upper outlets for decorative window lighting. Both of those are things I wouldn't necessarily have thought of as an amateur. Great video
@2shoestoo
@2shoestoo 6 жыл бұрын
I think outlet covers are on backorder now at Home Depot
@BenjaminSahlstrom
@BenjaminSahlstrom 5 жыл бұрын
How did you know!
@josephdestaubin7426
@josephdestaubin7426 5 жыл бұрын
He's an HVAC technician, I seriously doubt he's buying his supplies at Home Depot.
@ricardovilloch4685
@ricardovilloch4685 4 жыл бұрын
@@BenjaminSahlstrom ]
@danlux4954
@danlux4954 4 жыл бұрын
@@josephdestaubin7426 usually get good deals at the hardware store instead of the electrical supply store.
@josephdestaubin7426
@josephdestaubin7426 4 жыл бұрын
@@danlux4954 Nonetheless, he still isn't going to buy electric supplies at Home Depot. While HD often has better prices on China made tools, they are nearly always more expensive in supply items.
@csilv
@csilv 4 жыл бұрын
Benjamin, thank you very much for this video. Our family is about to do a complete re-wire of an older house so I've been researching so that I can be better informed. I've found very little information about designing the circuit layout (which is odd since it seems so fundamental and important.) This is by far the best video I have found on the topic. Thanks much!
@bigsidable
@bigsidable 2 жыл бұрын
I just love the analytical and thorough explanation. Right on young man. Good job. We need youth like you in the future.
@sku32956
@sku32956 5 жыл бұрын
This is a tech nerd dream more out lets then a dude can ever use .I would have liked to see the rough in, that was a thing of beauty .Glad to see a young man in the world working his ass off .
@desireeespinosa3954
@desireeespinosa3954 3 жыл бұрын
I just subbed because of your current 2021 videos.... I have to say you are adorable. Intelligent... and obviously driven. Thanks for all of the tips!
@nickv1008
@nickv1008 5 жыл бұрын
With enough outlets, who needs sheetrock.
@dennismiller9681
@dennismiller9681 4 жыл бұрын
OK, that comment actually made me chuckle !!!
@anaheimswillyg2238
@anaheimswillyg2238 4 жыл бұрын
Cold blooded 😂😂😂
@GDaShef
@GDaShef 4 жыл бұрын
lmfao....right
@curtisbme
@curtisbme 4 жыл бұрын
lol. Pretty much. I love me outlets, and would really love 12 gauge/20amp to all of them as I have some circuits that can get overloaded and trip. But the amount of outlets in that office setup is loco. I feel like despite all his electrical studies, nobody told him about extension cords and power strips. :-)
@nickv1008
@nickv1008 4 жыл бұрын
@@curtisbme I always like a bit of overkill on the wire. Did a garage in 10g, to the wall outlets, with 1 outlet 50 amp/220v ( for the compressor they never will use.) Eventually someone will appreciate it.
@rhdtv2002
@rhdtv2002 6 жыл бұрын
You are short one receptacle..just wanted you to know
@docferringer
@docferringer 3 жыл бұрын
Also forgot to tighten a screw on that one over there.
@superwiseman452
@superwiseman452 4 жыл бұрын
This guy is damn good. I am an electrical engineer, and this guy knows his $hit. I approve. stamp.
@EVERYDAYDON
@EVERYDAYDON 3 жыл бұрын
Thank you Dad :o)
@Bludcharg4214
@Bludcharg4214 3 жыл бұрын
Wow you're an electrical engineer!!!
@Shockimmunity
@Shockimmunity 3 жыл бұрын
Yeah... I dont believe that...
@arthurwarren2able
@arthurwarren2able 3 жыл бұрын
Electrical engineers don't know shit.
@Bludcharg4214
@Bludcharg4214 3 жыл бұрын
@@arthurwarren2able true, this guy is probably an incel.
@Rayram555
@Rayram555 4 жыл бұрын
Great video. I am an electrician and this video is explained very well. The way you communicate your knowledge tells me you are success . Thank you.
@amoledor
@amoledor 5 жыл бұрын
I was just telling a friend if I were to build my own house, this is how I would wire my house. As well as have each room on it's own circuit so if I am doing work in that room, the other rooms can still operate with no interruption.
@okein3602
@okein3602 5 жыл бұрын
Yes
@bobh6728
@bobh6728 3 жыл бұрын
I would split up the circuits in a room so if a breaker pops, you still have power in the room. For example, you need to work on the outlet in a room, you would want power in that room fit a work light etc. (I guess with everything going back to battery power that may not be such an issue.) Pros and cons both ways. I would just have the outlets on one wall together, so the north outlets in one room would be on the same circuit as the south circuits in the room that shares a wall.
@jonpancoast965
@jonpancoast965 4 жыл бұрын
Smart, Efficient, And right to the point. It is so refreshing seeing such a young kid being so smart and sensible. I'm an electrician since 1991, I'm not sure what this kid does but he has a bright future as an electrician. Although not really a lot of money in that. As a worker maybe a 100 grand a year.
@davidjohnson4198
@davidjohnson4198 4 жыл бұрын
Which is really good money for 95% of the population. Most college graduates don't make anywhere near that pay. Not to mention tax free side work. Good electricians are employable anywhere. Kid is impressive.
@delperz2371
@delperz2371 4 жыл бұрын
With his knowledge and attention to detail, it would be easy to start his own company. There is big money in that.
@zososldier
@zososldier 5 жыл бұрын
Good video. Only thing I would suggest adding would be at least 2 dedicated circuits for any living rooms due to possible large stereo or what ever, adding the 240v plug for anything that is gas in case someone wants the electric version in the future and I would say you would want dedicated bedroom circuits because kids don't give no craps about load ratings. You might not need more, but it would be awesome for the next guy if you end up selling the place. Can't say how many times I have shut off half a house or apartment because you end up using a hair dryer and a stereo at the same time. Heck, if I ever get to build my own house in the future, ill probably give every room a dedicated circuit (And more in the ones like the kitchen that obviously need more)
@a-pie21
@a-pie21 4 жыл бұрын
You are the most informative person I've found on youtube when it comes to electrical stuff
@javiermarquez2028
@javiermarquez2028 7 жыл бұрын
Holy mother...outlet heaven.
@trapavisionfilmz
@trapavisionfilmz 5 жыл бұрын
😂😂😭😭😭😭😭
@donaldgulledge729
@donaldgulledge729 4 жыл бұрын
I'm thinking more than a few of those were low voltage data/signal boxes. At least I hope so.
@bishopp14
@bishopp14 4 жыл бұрын
It's the exact opposite in my house. Whoever did the electrical here was NOT a fan of outlets at all. Plus they had zero idea what they were doing. I found a light in one of my bathrooms had the ground wire nutted in with the hot wire! I've never seen anything like that before...
@docferringer
@docferringer 3 жыл бұрын
@@bishopp14 Yeah, the older a house is the fewer receptacles in each room (in my experience anyway). Nowadays you need at least a couple of receptacles on each wall, networking, TV/phone....
@blackhorse2947
@blackhorse2947 3 жыл бұрын
I have begun saving nearly all your videos. Absolutely great information for the DIY. Thanks for your expertise
@conraderb
@conraderb 4 жыл бұрын
I love that this guy is like 20, has a huge house and already has kids
@dalczl
@dalczl 4 жыл бұрын
The first electrician I worked for thirty years ago wired lights and outlets separate. Great idea in my view. Inspectors in my area stick to a total number of receptacles per circuit breaker.
@user-cf8ir6iy6y
@user-cf8ir6iy6y 7 жыл бұрын
Thanks for the clear video.....One also really needs to plan outlets for temporary loads like space heaters and also vacuum cleaners. Many vacuums today are big amp draws.
@Icehso140
@Icehso140 3 жыл бұрын
10:16...garbage disposal. I have septic and got rid of mine when it started getting worn. A plumber told me it was bad for septic tanks, and the drains don't get rinsed enough to flush out all that food waste and can cause clogs. We don't miss it at all. Good video. Thanks.
@Ty-sy3nn
@Ty-sy3nn 7 жыл бұрын
You say its "common sense" but really its the load calculations you must perform that dictates it. Anyone doing a remodel like this should be following the NEC for these calculations as well as the inspectors. These calculations help tell the home owner the size of services (Demand Factors) needed coming into the home. Once you have your total Watts (VA) then you can break down what size breakers for appliances, then move to how many breakers are needed for the lighting load and receptacle load. Don't take this as a negative comment, I love your channel and I think people need to understand the entire picture of what drives branch circuits etc. Ref. NEC 210.70, 220.5, 220.12, 220.14, 220.42, 220.51, 220.52, 220.55, 220.60, 220.53, 220.54, 430.248
@BenjaminSahlstrom
@BenjaminSahlstrom 7 жыл бұрын
Tyler C Thanks so much for the well thought out comment. I totally agree. Well articulated and thanks again for adding value to those who see this video!
@DriftHyena
@DriftHyena 7 жыл бұрын
Allegedly the limit doesn't apply to dwelling units.
@thinkoutsidethebox5134
@thinkoutsidethebox5134 7 жыл бұрын
I agree I guarantee he is not a Electrician
@andyfam5613
@andyfam5613 7 жыл бұрын
Tyler C they're not licensed electricians. I think this vid was intended for diy people
@kefrenferrer6777
@kefrenferrer6777 6 жыл бұрын
NEC is a reference with no much sense in some cases, example asks for an outlet un the bathroom, what if i don't want any. Asks for an outlet every six feet on the walls, what if i don't want si much, asks calculate feeder minimum on squared feet áreas, that's really stupid, asks for 180 watts an outlet in some cases without no logical reason and avoids the same rule for dwellings, much of it's rules only are for the inspectors bother people.
@uggles2307
@uggles2307 4 жыл бұрын
Enjoyed this common sense approach to receptacles. Well done!
@stephenmalcome3797
@stephenmalcome3797 4 жыл бұрын
Drywall installer sighed when he saw the outlets
@erlycuyler
@erlycuyler 4 жыл бұрын
If he's like the ones I know,he probably didn't care because was going to cover half of them anyway and Nick the wires with his Roto zip on the other half and run a few screws in the wires for good measure to insure fits of hair pulling trying to find the shorts. Oh,and stack 5 tons of board RIGHT where ya gotta work. Meanwhile,the tin knockers are all up in your business. While the wood butchers are trying to run a whole sawmill on one temp circuit with all they cords tangled all over the world. As the insulation amigos are running amok with giant kitchen knives.lol. Typical day. Hahaha.
@Bewefau
@Bewefau 4 жыл бұрын
@@erlycuyler 0,0
@thompsonhandymanservices6088
@thompsonhandymanservices6088 4 жыл бұрын
@@erlycuyler That pretty much describes the situation lol
@milehigh3054
@milehigh3054 4 жыл бұрын
Lol
@bishopp14
@bishopp14 4 жыл бұрын
Yeah he sighed...right before he quit! Lol!
@JoshuaCussins
@JoshuaCussins 4 жыл бұрын
Thank you. From my understanding, you also want to split the circuits up evenly in the panel. Red/Black. So that the loads are evenly distributed to both main panel feed conductors?
@DriverDude100
@DriverDude100 5 жыл бұрын
2 years on, and this is still a fantastic video. Good work!
@guillermorodriguez5685
@guillermorodriguez5685 6 жыл бұрын
You forgot 24 receptacles on the ceiling
@daveorbit4165
@daveorbit4165 6 жыл бұрын
Lmao.
@salvadorochoa6465
@salvadorochoa6465 5 жыл бұрын
Guillermo Rodriguez yooo you krazy lmao yea this fucking guy just hammered the dry and said one here and another here
@TheDannytre
@TheDannytre 4 жыл бұрын
Dude!!!! 💀
@robert-to7ev
@robert-to7ev 4 жыл бұрын
No kidding
@Bewefau
@Bewefau 4 жыл бұрын
at least he doesn't have to run any extension cords. I'd like that many in my room with all my computer gear.
@LennyGildersleeve
@LennyGildersleeve 6 жыл бұрын
Give this homeowner the coveted " Unnecessary Receptacle Award"...presented by Carlon
@BenjaminSahlstrom
@BenjaminSahlstrom 6 жыл бұрын
Yes! I'll take it. So far I have been thankful for pretty much all of them. :)
@threecreationleather6596
@threecreationleather6596 6 жыл бұрын
..better to have it and not need it than need it and not have it !
@brentcos9370
@brentcos9370 6 жыл бұрын
How would you possibly know they're "unnecessary"? It's his home, not yours. Now be a good little boy and leave a nice comment for him as this was a nice educational video. Not your opportunity to nitpick and be petty.
@cobrastrike6043
@cobrastrike6043 6 жыл бұрын
@David Anewman that's probably the understatement of the year. Seems like everything that's used these days plugs into the wall, and that's before getting into networking, usb hubs, and home theater/gaming/PC systems.
@erlycuyler
@erlycuyler 4 жыл бұрын
@@cobrastrike6043 And not needing an extension cord to vacuum the hallway. Or put a box fan in hall without a cord to trip over,etc.
@MrStreetman1970
@MrStreetman1970 7 жыл бұрын
I agree with how you are going about figuring your receptacle count for your house (Since you know what you will be plugging into the outlets). If you plan on selling the house in the future, before you start wiring, you may want to check with a electrical contractor to find out what the total outlet count would be (If the contractor was doing the job) based on a new home install per 15A and 20A breaker to make sure the typical home user not knowing your plans for each outlet. Love the channel, keep up the good work!
@khadijagwen
@khadijagwen 6 жыл бұрын
Code in Oregon says that each bathroom will have a dedicated 20 Amp circuit. In Kitchen, 2- 20 amp circuits both represented on the counter top. Code enforcement varies from state to state. It is easy enough to look these things up. This from a Licensed Electrical Inspector.
@electricaf365
@electricaf365 3 жыл бұрын
Same in every state. NEC stands for NATIONAL electric code
@jcolumbiap
@jcolumbiap 2 жыл бұрын
I liked the code for the kitchen we used to have. One circuit for every two outlets and one circuit for the disposal and dishwasher.
@landonmintz4850
@landonmintz4850 9 ай бұрын
Well there are state modifiers to the NEC specific to each state so make sure to follow those.
@TAOicemicrophone
@TAOicemicrophone 6 жыл бұрын
What happened to the 5 ft 6 inches rule for receptacle height? Did this pass inspection?
@zachmerritt4661
@zachmerritt4661 6 жыл бұрын
That's an insane amount of outlets, good on ya though for knowing what you want. "Common sense" varies widely from person to person. Good vid thanks for sharing.
@skliros9235
@skliros9235 3 жыл бұрын
Do you have any recommended books or guides that give the basics for wiring a house? From installing meter box, panel, and everything else.
@parkershaw8529
@parkershaw8529 5 жыл бұрын
I finally see a room with too many boxes.
@nickv1008
@nickv1008 5 жыл бұрын
You cant have too many outlets !
@aurvaroy6670
@aurvaroy6670 4 жыл бұрын
@@nickv1008 Or can you?
@NoBeardPapa
@NoBeardPapa 4 жыл бұрын
Great to know , good info👍
@jacklawrence5226
@jacklawrence5226 5 жыл бұрын
Ben - very thought out electrical plan! Video one of the most informative on KZbin on electrical distribution in a house! Keep them coming!
@BenjaminSahlstrom
@BenjaminSahlstrom 5 жыл бұрын
Thanks! I am glad that you found it to be informative! Consider subscribing & ringing the bell as I have a lot more electrical videos coming!
@CASH-TO-THE-MERE101
@CASH-TO-THE-MERE101 5 жыл бұрын
👍👍👍👑👑👑
@jacklawrence5226
@jacklawrence5226 5 жыл бұрын
@@BenjaminSahlstrom Subscribed w/ bell on
@johngibson3594
@johngibson3594 5 жыл бұрын
Lights and outlets should always be on separate breakers this way if you overload an outlet you won’t be left in the dark. Don’t forget if you put a lot of outlets on one breaker and you exceed and trip the breaker it may turn of something that you don’t want turned off. More circuits to a room can be beneficial in that way. You should also balance your loads in the panel as well. I agree more outlets in a room is much better in today’s electronic gadgets. Codes in some areas are different and will have an effect on your planning. Plan it out is for sure the best thing.
@bigsidable
@bigsidable 2 жыл бұрын
Love the forward thinking. That’s detailed planning.
@ELIRAXPRT
@ELIRAXPRT 7 жыл бұрын
I like how you alternated the receptacles' circuits on the kitchen counter
@johnholfelder6724
@johnholfelder6724 4 жыл бұрын
ELIRAXPRT That’s a great idea.
@tomtippery5823
@tomtippery5823 3 жыл бұрын
Great work Ben. Years ago I wired a house near Rushford Minnesota, the owner was a chef. I wired the kitchen with 12-3 and split each receptacle into 2 circuits for him, he got a total of four circuits just in counter receptacle. Thought I would share with you. Keep up the good work, your work is outstanding. Have you written your masters license?
@danaharris503
@danaharris503 6 жыл бұрын
Hello Ben, for all your viewers, you can get free access to the 2017 NEC (Napa 70) at www.nfpa.org in read only format. You can get other years also, not just 2017.
@fsudave87
@fsudave87 6 жыл бұрын
Darn, read-only? You mean I can't edit it? :P
@gregoryv.zimansr4031
@gregoryv.zimansr4031 3 жыл бұрын
Very very impressive. You put a lot of thought into this layoff right down to Christmas lights. Did you put lights in the closets. My kids all bought used homes and one of the things we did is install lighting in them. It helps when looking for stuck etc. We also upgraded the outlets to tamper proof ones, these houses were all from the 70's. We also upgraded some of the switches to be combo switch/outlet . This way it isn't a hassle getting to a outlet to plug in vacuum etc. We are (old)... so there is no bending to plug in vacuums etc. I watched one of your other videos. You are doing a great job explaining all the steps. The way you wired up your circuit breakers in the boxes was a work of art. Did you learn this way from aircraft wiring?? Keep the videos coming and thanks for taking the time to make them.
@electricianattleborough1248
@electricianattleborough1248 7 жыл бұрын
Superb explanation of vital electrical safety considerations in the home. Well explained and very practical
@bm123ist
@bm123ist 2 жыл бұрын
Very informative and clear to understand video. Please address common and not so common encountered in older homes, in your future videos -thanks again!
@SuccessforLifester
@SuccessforLifester 4 жыл бұрын
Your video is recommended to me because Covid-19 lockdown is known as circuit breaker in Singapore
@jimpie231
@jimpie231 4 жыл бұрын
Great video! Only thing I could have added is dedicated switches to do things, like difference lighting arrangements in bedroom, kitchen, family room, outdoor lights, washroom,etc. A example of this in family room would be a dedicated USB charging outlet/switch at eye level when seated on your favorite lounge chair, separate outlet below for plug-in lamp and separate switch next to the USB switch. Garage lighting and switch arrangements, sub panel in garage. Thanks! Jim
@danallen1828
@danallen1828 4 жыл бұрын
Uhm but the code does specify actually. The code calls every yoked device (the little metal Mickey Mouse tabs you see on your receptacle) to be rated at 180voltamperes (or volts multiplied by amps.) So a 15amp circuit in the states would be 15amps x 120volts = 1800voltamperes. A 20amp circuit would be 2400VA You were right on saying 80%, so 80% of a 15amp circuit would allow you 1440 amperes of devices. Divided by 180 as the code rates them you get a total of 8 per 15amp and 10 for a 20amp Circuit. Also, What dictates the minimum in the room Is space between receptacle points. I think you Missed more than a couple Pages. Go back through and check out art 210
@scottbrown8418
@scottbrown8418 4 жыл бұрын
Thanks!
@waterbug1135
@waterbug1135 4 жыл бұрын
Thanks for correcting this.
@brittneywebb0502
@brittneywebb0502 4 жыл бұрын
IIRC there is an exception to that. The exception being general use receptacles in a dwelling.
@Acc-xt4wq
@Acc-xt4wq 4 жыл бұрын
Not only that , but he mentioned a continuous load, a continuous load is defined in the NEC as a load that is used continually for 3 hours or more at a time, such as a fridge or the likes of. but yes Dan Allen is correct
@rmcfarland6260
@rmcfarland6260 3 жыл бұрын
Nailed it!
@ArizonaArmwrestlers
@ArizonaArmwrestlers 3 жыл бұрын
NEC 220.14 each receptacle = 180VA . = 180VA/120V= 1.5A .....(1.5A * 10 = 15A). Max load allowed on a 20A circuit with more than (1) receptacle is 16A....NEC 210.21(b)(2)
@masternater6721
@masternater6721 6 жыл бұрын
the downside of splitting up lighting and receptacle loads is that when receptacle circuits fault and trip the OC device, you won't notice it as quickly, as when you have it tied into a lighting load... (you notice when lights are off, more than when your battery charger is off)
@Irishfan
@Irishfan Жыл бұрын
You notice when your power circuit goes out because you have lamps and appliances plugged in that quick working. Your battery chargers are not the only thing plugged into the circuit. Having worked in construction related engineering and having taken a class of electrical engineering systems for buildings, I can tell you that in most jurisdictions, separating the light and power circuits is standard practice.
@masternater6721
@masternater6721 Жыл бұрын
@@Irishfan having done the work i'm talking about for over 20 years, (not preaching a piece of paper on your wall), i can tell you, your 'jurisdictions' and ideals have no place in REALITY. those of us who DO can tell who the 'engineers' are and who the men who make things, are.
@richardhall9815
@richardhall9815 4 жыл бұрын
Is it a code requirement to have lighting and receptacles on separate circuits?
@ryanrasmussen2229
@ryanrasmussen2229 4 жыл бұрын
Yes
@electricaf365
@electricaf365 3 жыл бұрын
It depends.
@tspecht610
@tspecht610 7 жыл бұрын
please keep in mind the 1.5 amp rule of thumb is a better method than trying to calculate your particular plans because it needs to be safe for resale and the next owner may utilize the outlets on various circuits completely different than you.
@NorKavon
@NorKavon 7 жыл бұрын
tspecht610 if a new owner places different things in the outlet it will not be unsafe. They will simply trip the circuit breaker. I have 5 tools each drawing about 15 amps wired on the same circuit in my shop (and it passed inspection) I am 1 person so will never use more than 1 tool. But if a new owner tries to run 2 large amp tools at the same time it will just trip the breaker.
@1982MCI
@1982MCI 6 жыл бұрын
tspecht610 and always remember that we can not go thru life planning for what the next guy In line may do20 years from now. I’m worried about myself today, and if I follow the code that’s in place today as a minimum then the guy 20 years from now can make his own improvements and by then the codes will be completely different anyways. If someone else down the road is interested in buying the house then they either like it or not, it will either work for them or not. They aren’t going to buy x house down the street cause it had one more kitchen outlet than yours, they are going to call a handyman and in 2 hours it’s their perfect home. Live today for you, don’t worry about what I want 20 years from now
@stevansaucedo4151
@stevansaucedo4151 5 жыл бұрын
Please have the next owner call me. I can install additional dedicated receptacles for him.
@javisreef2807
@javisreef2807 5 жыл бұрын
@@1982MCI so true at my house the dishwasher is plug in in the basement in the same outlet as the washer and dryer .I also have the filtration for a 120g saltwater aquarium never had any issues .
@gillmoni64
@gillmoni64 3 жыл бұрын
I have learned a lot from you, you really know electrical wiring, to be so young 👼 you don't look a day over 17, but I'm sure you get that alot! Keep up the good work and thank you for all the good learning!
@aurvaroy6670
@aurvaroy6670 4 жыл бұрын
"I don't really love having a microwave in the kitchen..." Wow that's a first
@KylersStudio
@KylersStudio 4 жыл бұрын
That's when I stopped listening. We are not speaking the same language haha
@whatdoyouthinktodd
@whatdoyouthinktodd 4 жыл бұрын
Does his wife like a microwave in !HER! kitchen or does he tell his wife what to do yeah that will last long. The wife is the Boss if we want to get lucky!
@RogerSwayze
@RogerSwayze 3 жыл бұрын
Ben I really appreciate your recommendation of the SENSE home monitor sensor. I ordered on and I really like it! Thank you for recommending such a great product. Much appreciated!
@mistyman411
@mistyman411 6 жыл бұрын
Ive wired a lot of homes.average would spin off 12-13000 ft. 12 guage didnt use any 14.good choice on the QO panel.id end up with 2 42s and use all of them.3rd floor was run off a 100amp sub. youve got a bit over overkill on the outlets but doesnt matter.arc faults mandatory for bedrooms .fridge seperate circuit aswell as microwave.compactor doesnt have to be .just make sure all connections are torqued correctly Loose wires burn houses down
@zososldier
@zososldier 5 жыл бұрын
I hope you added an extra zero by accident. Considering a bunch of electricians will say about 2-3 feet of 12/2 or 14/2 per square foot as a general ball park.
@terryjames1635
@terryjames1635 5 жыл бұрын
Yep, back stabbed outlets almost burned mine down. Smelled hot insulation after my daughter used her hair dryer. Runner burned insulation back an inch from receptacle. I replaced about 30 of them house wide. About 5 were heat damaged but hey, I bet they were cheap. Went with spec. grade 20 amp rated. Not near as cheap of course but my wife and I are living in it every day..
@TortureBot
@TortureBot 5 жыл бұрын
Terry James when you say backstabbed outlets, I guess you are talking about where people jammed the wires in those quick connects on the back? I always hated those. When we built my house I made sure to put the hook in the end of the wires and torque them down well. I did find a couple of outlets that a family member helped with that were loose. One of them they forgot to tighten the screws down at all and it was for my refrigerator! The side of the outlet had melted slightly. Another one was in the living room for an outlet that we didn't ever use for some reason, probably because the way the furniture was positioned. One year we rearranged the furniture and my wife plugged a floor lamp into that outlet and started using it. I kept smelling something and traced it back to that outlet. I cut the power off and pulled it loose and found it had the same problem. I went through a bunch of the outlets checking them but there are still some I need to double check upstairs. It's scary to think something arcing can catch your house on fire.
@b58hustler71
@b58hustler71 3 жыл бұрын
This young man is impressive and organized.
@rotnkiley
@rotnkiley 6 жыл бұрын
this is like a woman's dream all these plugs!!! my dream home with the plugs up high!!! no bending!
@GeoffreyHowells
@GeoffreyHowells 3 жыл бұрын
Working on completing my KZbin master's electrician degree... Great description and planning of intended load usage.
@amrosla67
@amrosla67 6 жыл бұрын
Great job Ben, some may think you’re over killing a project, but I sure get a kick out of some people who build a house or shop and it’s only got one light and outlet for the whole garage!!! Nothing but extension cords!!!
@zososldier
@zososldier 5 жыл бұрын
You just described my 2 car garage. It has 2 wall outlets and 2 light outlets on the same circuit.... and it was an addition... I just don't understand. How can a person, working in construction, build something that they themselves couldn't use? I'm not saying that they need 3 240v outlets and 3 dedicated 120v circuits but come on. How is anyone supposed to run the in garage washing machine, an air compressor, a radio and the lights on the same circuit? "Well, I wanna use my table saw, better turn the lights off. Op, the compressor just kicked on, better go pause the washer"
@terryjames1635
@terryjames1635 5 жыл бұрын
Yep, my new house was wired to code (receptacle every 10' of wall). Drove me crazy (extension cords needed every where). After doubling number of outlets almost everywhere, am fairly satisfied. May need a few more here and there but much better. Would have been lot easier if done during rough in! Two bathrooms on one 15 amp circuit but that's another story. The rest of the house was all on 20 amp circuits with 12 ga. runners so didn't have to rewire any thing exixting except back stabbed outlets that should be outlawed. Almost burned the house when it developed high resistance at point of connection and burned off insulation back from the outlet! I replaced all of them after I smelled smoke from that one. This house was wired to code and passed ispection but some times a little extra above what is required is appreciated later on.
@nova31337
@nova31337 4 жыл бұрын
Love the alternating of circuits for the kitchen receptacles. More houses should make that standard practice, as I'm dealing with a house that put too many kitchen outlets on one circuit and it finally gave up and now the breaker needs to be replaced.
@armymobilityofficer9099
@armymobilityofficer9099 7 жыл бұрын
I enjoyed your video. Just an idea - most houses wind up being sold eventually, so don't just assume that all subsequent owners will have the same use that you have. Assume the worst.
@BenjaminSahlstrom
@BenjaminSahlstrom 7 жыл бұрын
+Army Mobility Officer Good thought. In my case I don't anticipate selling my place so I did a few more specific wiring things.
@turboflush
@turboflush 7 жыл бұрын
Army Mobility Officer Thats also where the breaker comes into play. If it starts to pop, then the circuit is being used for more than was intended.
@kingkilla421
@kingkilla421 7 жыл бұрын
its bad ass when u wire your own home.... You can make sure every thing has its plug with no cords....BTW i have been told there is a min amount of plugs per wall by code so u dont use cords to power things from a outlet. from what i know u have to have a plug every 6 feet... makes sense cuz most people use a 6 foot cord when the outlet is to far away
@joshuma32
@joshuma32 6 жыл бұрын
ben h the code states that receptacles shall be placed in such a way that at no point along the floor line of any wall space is more the 6 ft. The spacing between receptacles can be larger so long as you are within 6ft of a receptacle at any point along the wall. Check the code for more information on what is considered wall space and other things you should know.
@terryjames1635
@terryjames1635 5 жыл бұрын
That is minimum. I wound up needing almost twice as many to minimize extension cords. I still need an extension cord ocasionally for a light or clock but not often. I know contractors only bid the minimum required to get the bid.
@hdtvkeith1604
@hdtvkeith1604 3 жыл бұрын
Your work is so amazingly detailed and clean. Would love to live in a home wired by you.
@ashleygraham1011
@ashleygraham1011 7 жыл бұрын
I'm about to rewire a property I bought and my thought was to wire outlets separately than lighting. Thanks for this video!
@kike8008
@kike8008 5 жыл бұрын
Thank you very much for the video I finally clear my mind from all this different ways that electricians do their jobs but I believe your way make a lot of sense .👍
@kevinmcbride8980
@kevinmcbride8980 7 жыл бұрын
good thing he's not a plumber
@MemoGrafix
@MemoGrafix 6 жыл бұрын
Faucets everywhere.
@NorthernWindNut
@NorthernWindNut 6 жыл бұрын
Kevin Mcbride actually he is a licensed master plumber lol
@daniellee1509
@daniellee1509 6 жыл бұрын
All pipes in parallel, so when one gets plugged the other automatically takes over.
@dlamarsobotor4573
@dlamarsobotor4573 5 жыл бұрын
He should be, he is certainly not a qualified electrician !
@nickv1008
@nickv1008 5 жыл бұрын
@@MemoGrafix water hammer arrestors everywhere.
@Bewefau
@Bewefau 4 жыл бұрын
What if you had a main panel outside on a pole and a another panel on your mobile home. Would be a good idea to have one of those breaker's in each panel? Do you know if that will miss up the surge breakers ? I have my water pump on the main breaker on the telephone pole and the house has its own panel.
@tomsviewphoto
@tomsviewphoto 4 жыл бұрын
Hi Benjamin. New subscriber here. I’ve been learning a lot from you. I live in Northern Ontario and we get cold winters like you do in Minnesota. As such, personal space heaters are often desired for bedrooms. I would design my electric layout to include each bedroom on its own circuit.
@wizard3z868
@wizard3z868 4 жыл бұрын
i did one better i live in the north east i wired a separate outlet 15 amp next to one window in every room for an a/c or space heater
@jcolumbiap
@jcolumbiap 2 жыл бұрын
@@wizard3z868 Since most electrical heaters are 1500 watt I would have done a single 20 amp circuit Definitely spooky stuff to figure out!
@wizard3z868
@wizard3z868 2 жыл бұрын
@@jcolumbiap it's not spooky 15 Amp is 1800 watts so 1500 watt heater is like 82% of max load when you learn the math it's not so scary. if you can spend the extra money on wire and now more money for the tamper proof outlets and afci breakers nothing wrong with it
@21gonza21
@21gonza21 3 жыл бұрын
So If I’m using a 200 amp panel, I can only run enough breakers that add up or under 200 amps, example, two 30 amps+ five 20 amps+ two 15 amps = 190amps?
@treystills
@treystills 7 жыл бұрын
Ben you are my new hero. Your stuff is seriously awesome!!! That main panel is one of the cleanest I've seen. I'm wondering if you could create some content on the simple aspects of electrical such as how you place your wires so neatly in the panel, how you run your wire and keep it neat and organized in the wall or in the joist, service loops (you've got some "S" shaped loops above your master bed closets) etc. What does the "DF" lettering mean on your panel diagram? Love your stuff! Thanks again
@spelunkerd
@spelunkerd 3 жыл бұрын
Having done remodeling in the past, it is very nice to find circuits that are not completely full, since you'll eventually want to tie something else into to them later. Canadian code is still very explicit about the number of devices on each circuit, lower draw from LED's notwithstanding.
@PetrCTale
@PetrCTale 7 жыл бұрын
If the outlets on the stairs are for night lights? skip them and install step lights it a much cleaner look.
@BenjaminSahlstrom
@BenjaminSahlstrom 7 жыл бұрын
Craig Price Great suggestion. Do you have a specific product you would recommend? Is there a type of stair light that fits in a single gang box that you know of? Thanks for your comment!
@PetrCTale
@PetrCTale 7 жыл бұрын
There are many manufactures out there. WAC and Lightolier are two that come to mind. Google led step light should bring many to the screen.
@RC-Heli835
@RC-Heli835 3 жыл бұрын
Love all the outlets man! Also I like the idea of every other outlet being on a separate breaker. With the fridge on in our kitchen and the dishwasher and a space heater.....one more thing like the air fryer , microwave or toaster will trip the breaker.
@6610PiG
@6610PiG 6 жыл бұрын
I like the way u did it usually they do it room by room but this is different its a good way to do it though a little more organized for sure thumbs up
@philmoorehouse8064
@philmoorehouse8064 4 жыл бұрын
I didn't see this posted, is there a reason you put all the 240 loads on one side and the 120 loads on the other?
@bigvitojr
@bigvitojr 6 жыл бұрын
The problem is . When you sell your house . They will not know what you did because you went off the standard install . That is why we use code ( standards )
@BenjaminSahlstrom
@BenjaminSahlstrom 6 жыл бұрын
Good point and that is something to definitely keep in mind. Everything was done to code still in my installation but it definitely is not 100% "standard" or "builder basic". Thanks for your comment! Blessings, Ben
@driller840
@driller840 5 жыл бұрын
Hey guys.... standards = mean the minimum required or the max. allowed?
@pistolero114gunner
@pistolero114gunner 5 жыл бұрын
Standards suck. Unique is better lol. That was a question i had for a long time now I'll be doing some rewiring at home 👍
@jerseyscaler445
@jerseyscaler445 Жыл бұрын
Exterior lighting sconces. If you had a bunch what's the best circuit to put them on ?
@brianmanning34
@brianmanning34 6 жыл бұрын
I say just put 20 outlets every on every wall because I have a lot of gizmo's to plug in lol
@frankgorgone4879
@frankgorgone4879 5 жыл бұрын
Receptacles are rated at 150 watts each. Watts divided by volts equals amps
@frankgorgone4879
@frankgorgone4879 5 жыл бұрын
Sorry it’s 180 watts per receptacle So a 15 amp circuit is 10 and a 20 amp is 13. Also your large appliances i.e. washer dryer refrigerator should all be dedicated circuits. And your bathroom GFI’s can’t leave the bathroom
@jeremyloftin2027
@jeremyloftin2027 4 жыл бұрын
That rating is for commercial buildings.
@gyrgrls
@gyrgrls 5 жыл бұрын
A few tips from a retired electrician: Dedicated circuits are often indicated where tolerance of interruption is low, such as lighting in work areas, or critical loads like computers or medical equipment, especially where backup power is not employed. Other than that, I prefer not to wire rooms so that they share a circuit - this can cause nuisance tripping. The old adage that "I wire my rooms so that the room isn't totally dark if a breaker trips" is poppycock. Better to have two circuits per room. As for kitchens and utility rooms, I like dedicated GFI circuits. Kitchen appliances draw a lot of current, and some have low power factor. Circuit breakers are cheap. Wire is fairly cheap. It is elementary to run a 12/3 to two separate breakers on a duplex receptacle. Neutral can be shared if it's wired to opposite polarities (as if in a 240 v circuit in the USA). In this case, the breakers should not be ganged. Twin breakers use a common lug in the load center, and can allow for the additional desired circuits. There really is no good reason for wiring two rooms to a common circuit or overextending a home run.
@leonardholt5311
@leonardholt5311 4 жыл бұрын
John Bond yea, you must not have been much of an electrician. Good thing you’re not in the field
@wizard3z868
@wizard3z868 4 жыл бұрын
look into arc faults the 14/3 12/3 branch circuits with arc faults are in the past
@K31swiss
@K31swiss 3 жыл бұрын
Multi wire circuits are becoming a thing of the past with a lot of the electronic stuff these days.
@exrezcnm
@exrezcnm 4 жыл бұрын
Question: you do not need a dedicated circuit for a refrigerator?
@wizard3z868
@wizard3z868 4 жыл бұрын
some jurisdictions maybe not but most find it a reasonable way- so why not you really will not save much money also i run my smokes/co2 off of the fridge(and i never tell pple) good luck finding the breaker unless you want warm food lol
@bretonkyle
@bretonkyle 4 жыл бұрын
Dedicated outlets for christmas window lights We ain't living the same life
@Rextrent
@Rextrent 4 жыл бұрын
Well, then. Drop and give us 20!
@michaelm3255
@michaelm3255 4 жыл бұрын
I did that too and it's really convenient. One switch turns all the lights in the different rooms on and off.
@miker648
@miker648 4 жыл бұрын
Ben, I thought the code regarding kitchen counters was, so many watts per running foot of counter?
@leonardholt5311
@leonardholt5311 4 жыл бұрын
Michael Renner you thought wrong
@bjre.wa.8681
@bjre.wa.8681 4 жыл бұрын
A very "FULL PANEL". I would have liked to see the wire management in that load center!
@BenjaminSahlstrom
@BenjaminSahlstrom 4 жыл бұрын
You can see it actually! I made a video of the entire process and you can watch it here: kzbin.info/www/bejne/hWWre3iOac5rf8U
@dominicbenecasa7893
@dominicbenecasa7893 2 жыл бұрын
Been wiring houses a simple way each bedroom gets its own recepticle circuit. Bathrooms on one circuit. It uses more breaker spots but I always use 40 circuit 200 amp panels. I did mostly commercial work so the little bit of housing I did was for side jobs. They never failed an inspection. Follow the code for the kitchen it has changed over time.
@MichaelVecchio-r5m
@MichaelVecchio-r5m Жыл бұрын
Waste of wire.. technically you could do 3 bedrooms on one 14 amp circuit .. no one uses all plugs at the same time..
@greenlinefarms5274
@greenlinefarms5274 7 жыл бұрын
Looks like a grow room setup
@storungz
@storungz 6 жыл бұрын
LOL!!!!!!
@Maylen110
@Maylen110 6 жыл бұрын
🤣😂🤣😂😂😂😂😂🤣😄😄😄🤣🤣
@pierredelecto7069
@pierredelecto7069 6 жыл бұрын
Tin foil the walls! Saw it on a documentary made in canada in a trailer park.
@pierredelecto7069
@pierredelecto7069 6 жыл бұрын
@@vids595 i did for almost 100 of them..... I also worked for gavita, a rather large portion were used at 120. All depends on the size of the operation and the ballasts at hand. Just uses more copper to wire at 120. I spent more every month on elec bill than i did on wire.
@mimi12251973
@mimi12251973 5 жыл бұрын
I was thinking that as well
@Graphitegrey
@Graphitegrey 3 жыл бұрын
Is that a NEC code or local code when you are talking about the dinning room and stairs hallway being on the same circuit
@theodoreroberts3407
@theodoreroberts3407 5 жыл бұрын
Thank you. No one has ever answered that question for me.
@jcolumbiap
@jcolumbiap 3 жыл бұрын
In Tulsa in the 70’s it was 2 outlets per circuit in the kitchen, garage and dining room. Common outlet circuits were ten outlets per circuit on a 20 amp circuit. Each bathroom utility room, and hear/air unit had it own circuit. Lights were 9 outlets per circuit and all wiring was 12 guage on a 20 amp circuit. Code is helpful!
@jeremyanderson3819
@jeremyanderson3819 4 жыл бұрын
Says it right up front, there is no rule. Otherwise, you can calculate the expected loads and limit a circuit to approximately 80% of its rated capacity. Easy to do with lights, as for receptacle counts dont forget the vacuum cleaner, so leave capacity on common outlets and dedicate things like entertainment centers.
@nicknamednickify
@nicknamednickify 2 жыл бұрын
Hi Matt, can you have multiple HVAC units on the same breaker?
@jamesflorad8010
@jamesflorad8010 7 жыл бұрын
I did house wiring for over 30 years and you did a ok job but it was a little over kill i only use 20 amp where you need it washer dinning kit. bath room rec. can not have any thing else on the circuit you can put all rec for all baths rooms on one breaker but I would make each bath rec. on its own just because you do not want your doter and wife useing a hair dryer at the same time unless you know of a idem that well need 20 amp that being said on a 15 amp circuit I count each rec. as 2 ponents and a light as one point for a total of 13 or less on a circuit. now in the new codes your bedrooms need to be on a ark fallot breaker so I would put each bedroom on its own breaker as for the kit. I only put two rec. per breaker with the ref. on its own and for your range hood I would of put a 20 amp just in case down the rood you wanted to put a microwave and I would of put a 50 amp for a range just for resale if anything else but as I said great job.
@--JohnDoe
@--JohnDoe 6 жыл бұрын
james florad - damn son learn to spell.
@tyereksmith8946
@tyereksmith8946 6 жыл бұрын
nice job dude. advice thoe take some spelling classes ok no disrespect ok
@donford4369
@donford4369 6 жыл бұрын
@Kelly Chase Offield Is that all it took for you to bail...his spelling was not up to your standards? There is a thin line between genius and insanity...and some of us cross that line on a regular basis. So his spelling missed some words. His information was worth the effort to have to deal with his extremely easy to read comments. I rather enjoyed his way of speaking and writing. If you are in, or thinking about this type of work as a living...you better get prepared for dealing with a customer base made up of every kind of person in the world. If his spelling sent you packing...what are you going to do when you are in an attic, in August, it's 104° outside...and 156° inside the attic...you're belly crawling in insulation , looking for a problem you have to find, fix, deal w/customer, paperwork, dispatcher calling...on a Saturday afternoon, late afternoon...545pm...you had plans, the part you have on the truck is a broken pos your helper put back on the truck. You're fucked...right. Nope. You call the supply house to open for you and head that way. By the time you get back to the customer it's 702pm. You finally finish at 1145pm, Saturday night. You could have an entire day of calls like this. You ready for this. I'm 62 and just got home at 2am..my customer is happy, I'm happy and paid.
@nickjw88
@nickjw88 6 жыл бұрын
@@tyereksmith8946 Taught to read and write using Whole Language doesn't impact how knowledgeable an electrician he is.
@TortureBot
@TortureBot 5 жыл бұрын
When we built our home way back around 1998 I pretty much wired the whole house. I read books and watched videos so I could learn to do it myself. Back then everything I saw or read used a points system. I think the videos that I watched were basing circuits on 8 points. They counted outlets as 2 points and light fixtures as 1 point. It just recommended not to go over 8 points total on a circuit and that's what I stuck to. I used 12 gauge Romex for all the wiring and 20 amp breakers. My wife's uncle was building the house with us and he said that would be better during the building phase because we could plug power tools and such into the 20 amp circuits without tripping the breakers, and later on it would be better to have the thicker gauge wires and higher amp breakers after we started living in the home. I feel okay about all of that, but I am telling you it was a pain in the ass in some places to cram those thick 12 gauge wires back into certain boxes. What made it worse, the bottom story of our house is logs, and I had to use a router to route out my own boxes in the wood. I couldn't get the router to plunge as deep as I wanted, so the wiring was extra tough to fold back into the routed boxes. Every time I help family members with any type of electrical work, I always envied the fact that most of them have the 14 gauge wiring which is much easier to work with. Flash forward about 20 years, and I am now taking industrial electronics for a 2-year degree. I am learning a ton about electronics, electricity, wiring, motors, and of course, Ohm's law.
@gscalise45
@gscalise45 3 жыл бұрын
Would I be able to use a reclaimed 4 gauge wire that is scratched and has nicks in it coming from a main panel to a subpanel???
@yogibearstie
@yogibearstie 6 жыл бұрын
I would be living in that mess for the next 5 years trying to find time and inspiration to finish it. Btw with LED bulbs common does it change the designs? Good luck. 👍🏻
@percyfaith11
@percyfaith11 3 жыл бұрын
It lowers the watts per lighting outlet.
@gscalise45
@gscalise45 3 жыл бұрын
Would I be able to use a reclaimed 4 gauge wire that is insulated if it has scratches and nicks on it for a sub panel connecting to a main panel??
@m3rdpwr
@m3rdpwr 5 жыл бұрын
You can never have too many outlets!
@leoawag8515
@leoawag8515 3 жыл бұрын
For example I am using double pole circuit breake and then out of stock of double pole pole, can I use single pole? is that the same process? Thank you.
How To Rough In a Switch Box Feeding Lights & Outlets
18:50
Benjamin Sahlstrom
Рет қаралды 678 М.
Electrical Home Runs
7:37
Electric Pro Academy
Рет қаралды 101 М.
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 96 МЛН
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
How many lights can you put on one 15 amp or 20 amp breaker.
4:44
Bevins Builds
Рет қаралды 161 М.
Won't These Melt?!? 15amp Receptacles on 20 amp Circuits!!!
11:47
Electrician U
Рет қаралды 1,2 МЛН
Avoid Disaster! 8 FATAL Outlet Mistakes Most DIYers Unknowingly Make!
16:50
Electrical Wiring Basics
23:40
BrettleyBuilt
Рет қаралды 3,1 МЛН
Can 15 Amp Outlets Be Used On A 20 Amp Circuit Breaker
8:13
Everyday Home Repairs
Рет қаралды 569 М.
Why Neutrals and Grounds are Separated in a Sub Panel
17:46
Benjamin Sahlstrom
Рет қаралды 3,6 МЛН
Avoid These 5 DIY Electrical Mistakes
8:28
Everyday Home Repairs
Рет қаралды 462 М.
How NOT to Wire Light Switches in 2024 (New Rules)
15:21
Backyard Maine
Рет қаралды 1,5 МЛН
10 Common Mistakes DIYers Make In Circuit Breaker Boxes
13:55
LRN2DIY
Рет қаралды 2,7 МЛН
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 96 МЛН