How To Wire A Garage - EASY Electrical Wiring Basics For Beginners (Workshop, bathroom, and more!)

  Рет қаралды 474,377

The Excellent Laborer

The Excellent Laborer

Күн бұрын

In this video, I show how to wire a garage for electricity. I explain when I use 12/2 vs 14/2 wire for 20 amp or 15 amp circuits. I wire new outlets and switches for the garage from in this tutorial. The wiring basics I show here are the same wiring basics I used when I made a video on how to wire a house. This video covers start to finish from wiring outlets and 3 way switches to wiring the breakers in a panel. #electrical #electric #construction #diy Check out this video to see how I made the final connections to all of this wiring • How To Wire A Garage -...
My Favorite Tools And Supplies 👉 www.amazon.com/shop/theexcell...
Tools And Supplies Used In This Video👇
ALL my favorite electrical supplies amzn.to/3s4UKST
12/2 Romex Wire amzn.to/3tJoPI8
14/2 Romex Wire amzn.to/3rYJPtZ
14/3 Romex Wire amzn.to/3SaeW0q
12/2 UF-B Wire amzn.to/3s0XQHo
Wire Stackers amzn.to/3s7ZAyz
Halo 6" Recessed light housings amzn.to/45JIbKi
Bathroom Fan amzn.to/3QtnVrW
Klein Wire Strippers amzn.to/45DxnNT
More Helpful Related Videos👇
Electrical Playlist • Electrical
How To Wire A Garage - Receptacles, Switches, Lights, and Fan Installation! • How To Wire A Garage -...
How To Build A Garage - ULTIMATE STEP-BY-STEP GUIDE • How To Build A Garage ...
How To Wire A Sub Panel - VERY DETAILED INSTALLATION! Start To Finish • How To Wire A Sub Pane...
How to Install PEX Pipe: Easy DIY Tutorial for Beginners | Step-by-Step Guide • How to Install PEX Pip...
How To Wire A 3-Way Light Switch - 3 Way Switch Explained (2 EASY & SIMPLE Methods) • How To Wire A 3-Way Li...
🟢 Become a channel member:
/ @theexcellentlaborer
🔴 Subscribe to this DIY channel: kzbin.info...
🟡 Check out my Amazon store: www.amazon.com/shop/theexcell... . Here you will find tools and supplies used in my videos. (DISCLAIMER- I am an Amazon affiliate. I get a small commission that helps support the channel at no extra cost to you)
Timestamps
Intro 00:00
14/2 Wire VS 12/2 Wire 00:00:47
Wiring Supplies 00:02:26
Garage Door Receptacle Placement 00:05:05
6/17 Rule Explained 00:06:51
How To Rough In Outlet Wiring 00:07:54
Half Bath & Utility Sink Wiring 00:20:05
Workstation 1 Wiring 00:22:53
Outdoor Kitchen Wiring 00:24:25
Upstairs Receptacle Wiring 00:27:03
Workstation 2 Wiring 00:29:34
Garage Light Wiring 00:31:31
Ceiling Fan Wiring 00:37:47
Recessed Light Wiring 00:39:36
Switch Boxes 00:43:13
Bathroom Fan & Lights Wiring 00:45:34
Exterior Flood Light Wiring 00:50:43
Upstairs Recessed Light Wiring 00:54:25
Wire Stackers For Wire Management 00:55:38
How To Wire Receptacles 00:57:45
How To Pigtail A Receptacles 01:01:56
How To Wire Switch and Outlet In 2 Gang Box 01:05:40
How To Wire A 3-Way Switch 01:07:53
Wiring 2 Circuits in 1 Switch Box 01:09:55
Nail Stoppers Installation 01:14:07
Sub Panel Circuit Breaker Wiring 01:14:58
Disclaimer: This video is all based on my personal opinion and is for entertainment purposes ONLY. I am not a financial advisor, CPA, attorney, tax advisor, electrician, plumber, housing contractor, designer, or any type of profession to give advice. I am just a consumer sharing my experiences and research. If you do need knowledge for those types of things, I will advise you to seek help for those professionals.

Пікірлер: 323
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
Hey fellow DIYers! Below👇are all the timestamps to help you navigate the video. There is A LOT of information packed in this video that will be helpful to use as a future reference to find specific information. Also, check out my membership offer where you can find exclusive content kzbin.info/door/UJXaEduMHGB3Iap3DusmAAjoin . Enjoy! Timestamps Intro 00:00 14/2 Wire VS 12/2 Wire 00:00:47 Wiring Supplies 00:02:26 Garage Door Receptacle Placement 00:05:05 6/17 Rule Explained 00:06:51 How To Rough In Outlet Wiring 00:07:54 Half Bath & Utility Sink Wiring 00:20:05 Workstation 1 Wiring 00:22:53 Outdoor Kitchen Wiring 00:24:25 Upstairs Receptacle Wiring 00:27:03 Workstation 2 Wiring 00:29:34 Garage Light Wiring 00:31:31 Ceiling Fan Wiring 00:37:47 Recessed Light Wiring 00:39:36 Switch Boxes 00:43:13 Bathroom Fan & Lights Wiring 00:45:34 Exterior Flood Light Wiring 00:50:43 Upstairs Recessed Light Wiring 00:54:25 Wire Stackers For Wire Management 00:55:38 How To Wire Receptacles 00:57:45 How To Pigtail A Receptacles 01:01:56 How To Wire Switch and Outlet In 2 Gang Box 01:05:40 How To Wire A 3-Way Switch 01:07:53 Wiring 2 Circuits in 1 Switch Box 01:09:55 Nail Stoppers Installation 01:14:07 Sub Panel Circuit Breaker Wiring 01:14:58
@bobchandler7186
@bobchandler7186 6 ай бұрын
😊😊
@gundamviewer17
@gundamviewer17 3 ай бұрын
Great video!!!! Huge Garage. By the way forgove meif youve said it but what state is this?
@atlantargh
@atlantargh 6 ай бұрын
This is a model of what a DIY video should look like: no dumb sound effects/visuals, no distracting music, no odd personalities or out of focus visuals, etc., just clear and concise information, presented in a no-nonsense manner.
@ESPspiderXIII
@ESPspiderXIII 5 ай бұрын
This here......is a goddamned fact.
@jimaronson2323
@jimaronson2323 3 ай бұрын
I really hate it when they use that high-pitched squeaky voice music. It's annoying.
@wishingwell1000
@wishingwell1000 13 күн бұрын
👍👏
@jamiehelmick5210
@jamiehelmick5210 5 ай бұрын
Man, I cannot imagine how much time you had to invest in the video potion of all this work. I've done tons of this work through the years (all before KZbin) and know the time it takes just to do the work, let alone the video documentation. Great Job!!!
@TheExcellentLaborer
@TheExcellentLaborer 5 ай бұрын
You are right, it is a lot of work Jamie! I really enjoyed doing it so that helps it from being a task. It is interesting how much time goes into a video when it’s all said and done. Sounds like you have a lot of experience with video. That is great! Thanks for watching!
@tnamen1307
@tnamen1307 17 күн бұрын
​@@TheExcellentLaborerSir one emergency question... A parallel circuit consisting of 2 same load/resistance where the total maximum current is 15 amp. It is protected by 15amp fuse. That means max 7.5 current is allowed in each wires. Now, I removed one of the load. And, I replaced the other second load with new load which consumes max 10amp. That means only one new load is connected in the circuit. That means there's more 2.5amp difference of current flow in the new load circuit. So, in the old load, max is 7.5 per wire. In the new load max is 10 per wire. So, just 2.5 amp difference. Now, coming to my question... If the new circuit is ON say for max 10 seconds, will the circuit immediately BURNS up within 10 seconds??? Of course, it will be hot. How long (30 secs etc) can the wire stay unburnt? How long can it stay safe? Or, How much extra current can be passed beyond the maximum limit for any given gauge wire?
@alanw356
@alanw356 6 ай бұрын
This is the first video of yours I've seen, and I guarantee - it won't be the last. I love your explanations of everything, especially tips n "tricks", your thoroughness, and how you fast-forward (but still Show) repetitive tasks - there's a lot of information contained there too. Clear speech, awesome camera work, lighting - Everything! You are an excellent tradesman AND teacher. Thanks so very much!!!
@xz4wkd
@xz4wkd 6 ай бұрын
Over an hour video of information, Thought I’d skim through this however I watched every single second. Great work, it’s now 3:05am.
@gloriamaiolini9507
@gloriamaiolini9507 3 ай бұрын
I did the same thing😂
@timliscum2861
@timliscum2861 6 ай бұрын
for the love of every DIY er who works in the garage put in at least one 30A circuit and a 220V outlet
@valleyscharping
@valleyscharping 2 ай бұрын
What for?
@brianb7388
@brianb7388 2 ай бұрын
@@valleyscharping if you want to have a big power tool like a 3 phase table saw you need 220. There's a ton of things you might find in a working garage that require a 220 outlet. If you're doing all this work it totally make sense to include 1-2 if not more. Jointer, compressor, dust collector all can be 220. even if you just work on cars having a big compressor makes a garage a lot more useful.
@BrooklinFunkProject
@BrooklinFunkProject Ай бұрын
@@brianb7388 not to mention the amplifier for your ham radio too!!
@jonchalk3855
@jonchalk3855 Ай бұрын
Wow. Great, not only for doing it yourself, but you can see if the electrician working on your panel is doing it correctly. well done.
@slyyam
@slyyam 7 ай бұрын
I just wanted to comment that because of your videos I went from being totally ignorant about electricity to pulling permits rewriting a room in my house saving me thousands of dollars. Thanks man you are fucking awesome!!
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
I’m glad you found value in my videos. I do have a ton of information on the channel and it’s very helpful for people new to DIY. Good luck with all of your other projects! Take care!
@Poscoobygarage
@Poscoobygarage 4 ай бұрын
With the help of your video I was able to bring electricity from my house panel to my newly built shop. I wired a new panel, ram circuits, set up outlets and lights so thank you for sharing your expertise. 👍👍
@allysonlleatherwood
@allysonlleatherwood 7 ай бұрын
I learn so much from your channel its crazy. Very well communicated information! Thanks. PS We installed our kitchen cabinets from your tutorial and they turned out great.
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
You are welcome! I am thrilled to hear that your kitchen cabinets turned out great! Thanks for being a viewer of the channel. I do try to put as much information to make my videos for one completed as I can. Stay tuned for lots of more videos to come!
@AdamS-lh2ug
@AdamS-lh2ug 7 ай бұрын
Also, to each their own, but why would you want your garage receptacles so low? As a homeowner doing this, don’t be afraid to move them up to whatever you want really, but you know, maybe counter height?
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
I placed receptacles at counter height where the miter saw workstation is going to be placed. If you check the timestamps, I explain that. I appreciate you watching!
@cato4603
@cato4603 7 ай бұрын
@@TheExcellentLaborerI love ur videos man thanks for making them I learned so much in the first 10 min alone
@JimN_AustinTx
@JimN_AustinTx 7 ай бұрын
Agree 36” to 48” for inside the shop is fine. I have plenty of work tables and it works great. 4 gang boxes as well for dense outlets.
@robb0995
@robb0995 6 ай бұрын
There’s also no requirement for so many receptacles in a garage. This “6/12” rule only applies to living spaces under the NEC. Only need one per bay and any “specific equipment” like the garage door opener.
@AdamS-lh2ug
@AdamS-lh2ug 6 ай бұрын
@@TheExcellentLaborer must have missed that! Apologies.
@josealfaro2220
@josealfaro2220 2 ай бұрын
Amazing video all done by yourself great thank you
@TheExcellentLaborer
@TheExcellentLaborer 2 ай бұрын
You are welcome.I hope you find my videos helpful. Thank you!
@50srefugee
@50srefugee 6 ай бұрын
Good intro to the task. A few tips from this DIYer: I rarely use a tape. Instead, I have a "story stick" with a few crucial measurements marked on it. (9", 12", 24" most often.) I use an Ideal Lil' Ripper to open Romex, and that happens to be 6" long. I also know how long my hammer handle and screwdrivers are. Chalk lines are the bomb. I make a habit of pulling the incoming feed cable through the top left hole in the box. If the Next Guy notices this, he'll thank me, since he'll know how all the boxes are done. Double check Sharpie for labeling cables. Always, always, always think of the Next Guy. The two-nail cable staples, with the white plastic saddle, are super, especially in tight spots. Zero chance of pinching the cable. The big blue Irwin auger bit is great--but for old work, cheap spade bits can be thrown away with minimal pain when hidden nails chew them up. If possible, when drilling I finish the hole from the exit side to avoid splintering, which might nick the cable. A block held against the back will also help if the stud spacing is too tight. Use armored cable or even conduit if your garage, basement, or shop will not have finished walls. I also use metallic boxes. I always use 12 ga wiring in utility spaces. Always. For everything. Except for heavy duty circuits that need 10 ga. I always use commercial or spec grade outlets and switches, not the commodity or residential units, especially not the ones out of the bargain bins. This goes triple for heavy duty use areas, such as the garage or kitchen.
@BryanPAllen
@BryanPAllen 6 ай бұрын
Thanks for the tips
@charlesreohr6236
@charlesreohr6236 6 ай бұрын
I use a wire stripper that has standard marks for differnt screw sizes. It also has a needle nose plier end to make perfect eyes to fit the screws.
@AdamS-lh2ug
@AdamS-lh2ug 6 ай бұрын
I mean no faults for going above and beyond. Sometimes a DIYer can be the best contractor. I have to admit I laughed a little bit reading your post. I’ve never seen a splinter go through a piece of romex but hell, if you sleep better at night then there ya go. Story sticks are nice, I guess, I would be kicked off a job for using one and being too slow. At the end of the day it’s all covered by dry wall so you just find a point on on your body (like your hip or what not), drop your right angled drill at a comfortable height and let her rip. Also, who wants to bend over to run wire?
@duanesamuelson2256
@duanesamuelson2256 6 ай бұрын
​@AdamS-lh2ug I assume you just set a laser for multiple outlets at the same height. Also I haven't used wood studs in years, including for load bearing walls.
@marvinwerth9421
@marvinwerth9421 4 ай бұрын
Yup! Used to have a "sacred stick" set for switch box hieght...
@mackfisher4487
@mackfisher4487 7 ай бұрын
Great Do-it-yourself video on basic wiring. One suggestion that makes replacing defective 3-way switches easier marker travelers between the two 3-way switches with blue tape. (As it's easier to confuse a black traveler with the black hot or black feeding a luminaire)
@50srefugee
@50srefugee 6 ай бұрын
HARD thumbs up. I've struggled with figuring out 3- or 4-way circuits where the wires aren't properly marked. I use six inches of blue or red shrink tubing (although I don't bother to shrink it.) This assumes I didn't run three wire cable, which is properly colored to start with. I'm a big fan of multiway switches, so I always have a spool of 12-3 on hand.
@nicholaspowell9813
@nicholaspowell9813 6 ай бұрын
Very detailed and informative. Thank you!
@suesheane3671
@suesheane3671 5 ай бұрын
That was a great video. Really informative and the time stamps are excellent for going back several times and reminder for each step , for those of who haven't done a lot of electrical. YOU have a great channel , keep up the great content! Merry Christmas 🎅 from Alberta, Canada 🇨🇦
@TheExcellentLaborer
@TheExcellentLaborer 5 ай бұрын
I do put the timestamps in the videos to give the viewer an opportunity to get to the information they are looking for. I’m glad you are enjoying my content. I appreciate the kind words. Merry Christmas as well!
@troydawson4017
@troydawson4017 7 ай бұрын
Very good and detailed. As a DIY it helps me better understand something’s I needed to know.
@waynedavis1713
@waynedavis1713 7 ай бұрын
Perfect timing. I'm about to run a new breaker and outlet in my garage pretty soon. Thank you for the very informative video!
@hunterstark9556
@hunterstark9556 Ай бұрын
Awesome video Josh!!!!! I love all of your videos! Fantastic job ❤❤
@kevinfortney364
@kevinfortney364 7 ай бұрын
Love your videos... I freaked out when you said you had to have 6" of wire past the front surface of the box. NEC 300.14 says 6" from where the conductor emerges from the raceway and a minimum of 3" out from the face of the gang box. Thank you for making these videos. I wired my own house partially from what you present.
@John-kj5wh
@John-kj5wh 26 күн бұрын
Thank you Sir for making such an in depth series. Lookin into getting into this work almost did earlier but opted for machine operation due to certain exteriror pressures that are no longer there. Im in the wrong field ahhhh lol. Thanks man.
@patriciadumatrait9594
@patriciadumatrait9594 2 ай бұрын
Thanks for all your help
@FrankCrocker
@FrankCrocker 7 ай бұрын
Super helpful video, thanks!
@paydent
@paydent 6 ай бұрын
its really helpful when you name the names of the fixtures and receptacles you are using when I go to make my pick lists for my projects. Keep it up!
@victorarcos6178
@victorarcos6178 28 күн бұрын
Thank you so much for sharing ! Greetings from TX!
@user-ex9kh3hy8c
@user-ex9kh3hy8c 6 ай бұрын
great video! very good job! I really like that you explain everything. Thank you for sharing your knowledge
@Ardoo19
@Ardoo19 4 ай бұрын
Very Professionally done!
@homesteadedman4784
@homesteadedman4784 7 ай бұрын
Great Channel, great video here also. I'm building a new garage shop area and I'm wiring it myself, so perfect timing. Thanks. cheers Edman
@shorthop65
@shorthop65 6 ай бұрын
Amazing video. OMG! Thank you so much. I have an unattached small shed. Can't wait to get it wired following your guidance.
@DubYaJsWorld
@DubYaJsWorld 7 ай бұрын
Awww buddy, im finished with my concrete and my walls and wiring are next. You are right on time with this video. Im about to get my note pad and save this video! Thank you for putting this information out.
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
Fantastic! I enjoyed all aspects of the building process. Everywhere from the foundation work to putting on shingles. I appreciate you watching the video. I hope it helps!
@TB-ki1ux
@TB-ki1ux 7 ай бұрын
Quality content as usual, thanks for sharing your impressive knowledge and insights
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
Thank you so much! I am thankful for subscribers like you that tune in to watch and leave. Great comments. Good luck with your projects!
@TB-ki1ux
@TB-ki1ux 7 ай бұрын
@@TheExcellentLaborer Thanks, Cheers
@chriserickson4417
@chriserickson4417 2 ай бұрын
Great video, thank you!
@catastrophenowimprovedfitn5383
@catastrophenowimprovedfitn5383 4 ай бұрын
Tremendous video, and a tremendous demonstration sir. Great video
@kenm8162
@kenm8162 6 ай бұрын
Being an avid woodworker I put outlets 50" off the floor to avoid them being behind sheet goods.
@tomgear4135
@tomgear4135 6 ай бұрын
Agreed ! Unless there is some foolish local code that requires they be at 16". My rule is, if it is for temporary connections (as most would be for a garage), mount them above the counter. Last thing I want to have to do is bend over every time I need to plug something in. We do some events where we setup our computer equipment in the customers office. It would have been great it when they wired it the outlets were above the work surface. It is a pain to have to get down on the floor and under the table to plug our stuff in. In a living room where you typically plug in your lamps and never move them, 16" is great.
@renzovc
@renzovc 6 ай бұрын
Subscribed !! Great channel man, thanks for teaching us 🤙 excellent info !!!!
@beauhurd3152
@beauhurd3152 4 ай бұрын
Great video. Even though i do a lot of electrical work I learn things from watching your videos all the time. Thank you!
@what66
@what66 6 ай бұрын
i decide to be a apprentice electirican soon, your video will help me a lot at this point, great thanks!
@stefboulas
@stefboulas 7 ай бұрын
Great video! You’re doing an amazing job explaining stuff very articulate. Great channel.
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
Thank you for your awesome comment! I spend a lot of time to keep my videos to the point yet very detailed. Subscribers like you make it worthwhile. Thanks for watching as well!
@michellelispi7941
@michellelispi7941 4 ай бұрын
This guy is a great teacher. I am excited, because I live ina place with the same you own it you can install it yourself code and now I think I actually can do it myself. Thank you!!! I'm watching and taking notes and learning tons!
@Rick-co4hm
@Rick-co4hm 6 ай бұрын
excellent presentation
@davidharrison3074
@davidharrison3074 7 ай бұрын
I always loved wiring my projects and making sure the codes are followed because so many cities can change something. One big example is to never have a freezer or refrigerator on a GFCI. If it trips for some reason, contents are a loss. Always knowing what style of light is a big help like you mentioned about LED style lights and plug in. I love the wire stackers because how neat it is, but this is another thing to make sure the code allows. Been told that insulation installs can create an issue for fastening it properly or spray insulation can cause a wire to come out. Again, it doesn't take much time to check out what is allowed and what isn't. Always love your videos and explanations. Till next time Josh 🔨👍🏻
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
I agree with you, David about making sure you are compliant with the codes of your jurisdiction. That’s an excellent point about having a freezer on its own circuit. That is the great thing about the halo housings, you can use the LED lights that plug-in, and they also make the socket style. I’ve been using the wire stackers for years and they are okay to use here. It makes securing the wires so easy and you can just click them out if you need to redo the circuit if needed. I will be installing a mini split soon, so I will have to run a wire for that on a double pole breaker. Thanks for your comment David and as always thanks for watching!
@unti419
@unti419 6 ай бұрын
@@TheExcellentLaborer If you put a fridge/freezer outlet in a space that requires GFI protection for other plugs, use a single recepticle instead of a duplex. That way nothing else can share that outlet. A duplex will get you rejected in many jurisdictions.
@hankkline7300
@hankkline7300 4 ай бұрын
N.E.C will require you to have GFCI protection on that freezer or refrigerator in the garage or kitchen, or anything anywhere else now..
@user-Ou8onetwo.
@user-Ou8onetwo. 6 ай бұрын
Nice bro, I learned a lot. Can't wait to see some more electrical work..
@PeasantGarden
@PeasantGarden 3 ай бұрын
Nice job explaining
@wannabetrucker7475
@wannabetrucker7475 7 ай бұрын
I wish this guy was my neighbor AND best friend. 😊 His videos are darn close tho 👍🏼
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
I appreciate your support. Subscribers like you that enjoy my channel make it all worthwhile. Take care!
@kumuppins95
@kumuppins95 4 ай бұрын
Superb video! Fantastic video editing! I learned so much about wiring from this! Even if I hire an electrician for my next wiring job, now I'm empowered with this special knowledge! Thanks so much for the video!
@envisibleward2422
@envisibleward2422 6 ай бұрын
I gotta tell you this is great!
@williamkiss5301
@williamkiss5301 4 ай бұрын
I have built a 30 x 28 garage in Northern Ohio which I will be tackling the wiring myself this spring. Great video. I look forward to watching your other vids. Well done.
@CharlesHarpolek4vud
@CharlesHarpolek4vud 6 ай бұрын
This particular man, i think, puts the best electrical information on KZbin that you can get. Whatever he says I would use yellow sheathing for AWG#12 DIY work because although it is harder to handle than AWG# 14, (white sheathing) your load resistance will be well served and who knows, you may want to use that circuit for something stronger. Remember to cut and not pull on plastic electrical tape until it breaks; the reason is that's the part that stretches when it gets pulled and broken will not stick down firmly on the end; pull to break the end that was pulled will eventually become loose and you have an poor ugly installation or little flags flapping in the air.
@foogod4237
@foogod4237 6 ай бұрын
Wire resistance for either of them is going to be pretty trivial unless you're doing a really long run somewhere (500 feet or more). The 12 gauge wire is also substantially more expensive, so it's really just wasting money to use it for things like lighting circuits, IMHO... But I do highly recommend running 20 amp (12 gauge) circuits for any circuit with any outlet receptacles on it. With appliance power consumption requirements nowadays it's really kinda dumb not to. (Also, if you're going to use 12 gauge wire everywhere, you should also use 20 amp breakers for all of it (there is absolutely no reason to put a 15 amp breaker on a 12 gauge circuit, and it's just confusing/unnecessarily limiting for people who come along later).)
@CharlesHarpolek4vud
@CharlesHarpolek4vud 6 ай бұрын
And really good reply@@foogod4237
@flyingjeff1956
@flyingjeff1956 6 ай бұрын
I was helping an old timer one day. I started pulling and straightening the wire. "NO!. Let it come off the roll", he said. And he was right. Smooth and easy.
@AdedoyinOyelaran
@AdedoyinOyelaran 7 ай бұрын
Thanks for this! I am planning to do exactly this: wire a detached 3-car garage + loft. This is an absolute god-send. Subscribed and liked!
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
Great! This will certainly be a good guide for you. Good luck with your project!
@coryd6396
@coryd6396 3 ай бұрын
Excellent. Makes me want to move to acreage and build a detached garage/utility bldg so I can run the electric!
@krumafreak
@krumafreak 7 ай бұрын
Great video, I'm about to wire my pole barn and this was a good refresher on some things. I'm curious how you are going to put a box on your conduit that is stubbed out of the floor for your workbench. I'm running two circuits like that and I haven't figured out how I'm going to do it so it won't be a trip hazard if I move the work bench and so liquids don't get in it if I spill something. I hope you include that in your next video. Please keep sharing your knowledge.
@espencer83
@espencer83 7 ай бұрын
Love your videos
@ryanmccarthy406
@ryanmccarthy406 2 ай бұрын
You’re great at videos man
@spreadcreekjr1731
@spreadcreekjr1731 3 ай бұрын
Excellent
@inthegarage.withalvaro.1344
@inthegarage.withalvaro.1344 5 ай бұрын
W O W what a video, thank you so much for doing this.
@JohnPooley-te9ei
@JohnPooley-te9ei Ай бұрын
Nice1..Lab & thank u
@walterpereira806
@walterpereira806 Ай бұрын
Very good
@a_cool_daddy2918
@a_cool_daddy2918 2 ай бұрын
Great job!
@TheExcellentLaborer
@TheExcellentLaborer 2 ай бұрын
Thank you!
@remodelaciones_sanchez
@remodelaciones_sanchez 7 ай бұрын
Tanks for teaching
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
You are welcome!
@rickmaberry8761
@rickmaberry8761 3 ай бұрын
Thank you. God bless
@anthonylawlor9130
@anthonylawlor9130 11 күн бұрын
Tip…. Layout all current and future layout of equipment and shelving, frig, freezer and incorporate it into outlet placement. Separate circuits for frig& freezer.
@rickmorris8242
@rickmorris8242 Ай бұрын
Is there anything you can't do.. I'm building my own home and i've watched all your videos.. Helped me so much Thanks
@zabik7221
@zabik7221 Ай бұрын
You are amazing man!
@TheExcellentLaborer
@TheExcellentLaborer Ай бұрын
I’m just a carpenter that loves making videos. Thanks a lot!
@gloriamaiolini9507
@gloriamaiolini9507 3 ай бұрын
Josh is a beast!!! Wish you were my son, grandson, or best friend so I could ask you stuff. All those wires. I got overwhelmed watching😂. I learned so things I had questions on and things I didn't know. I still don't know how you end up with 2 sets of (2 black, 2 white, 2 ground) wires coming out of your outlet. Mine outlets have one set of wires so I can't Daisy chain them. Can you do a video on how to add a newly wired receptacle to a junction box connecting an existing wire in the basement? 😊
@zekenzy6486
@zekenzy6486 7 ай бұрын
Great Video. Thank you for sharing. This Garage is big and large. Nice work and good job ^_^
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
I appreciate that! The garage portion is 38 x 26. The outdoor kitchen portion is 26 x 26. Plenty of room for me. Thanks a lot for watching!
@lawrencecorbo6586
@lawrencecorbo6586 5 ай бұрын
Great job of organizing !! The supplies !! I am looking for one idem I can’t find black square electric box under the certain tead siding box with built in jays
@billdlv
@billdlv 7 ай бұрын
Good video and information. You show 15A outlets on your 20A cicuits though.
@TheExcellentLaborer
@TheExcellentLaborer 7 ай бұрын
Thanks! We can use 15A outlets if it it’s not a dedicated circuit. I hope that helps!
@mcgravelgravel5675
@mcgravelgravel5675 7 ай бұрын
am building my house an always lern aalot from you thank bro
@kendavis8046
@kendavis8046 6 ай бұрын
I enjoyed the entire video, but FOUR screws on each side of the block for the ceiling fan made me smile. I understand it is overkill, but you might be able to attach a hoist to pull an engine on with that setup! Not even close to condemning overkill on anything that might fall on your head, so good job!
@MKimID
@MKimID 3 ай бұрын
Thank you for the detail information and instruction, If there are some more option, it will be helpful. such as if have a plan to install a solar panel, use 6+. if have a plan to use a electric saw/compressor.. 12 with non GFI.. ^^
@williamward3433
@williamward3433 6 ай бұрын
Very very good vidio!
@TheExcellentLaborer
@TheExcellentLaborer 6 ай бұрын
I appreciate that William. Thank you!
@tonywright4361
@tonywright4361 4 ай бұрын
Just run 12/3 make it easy.
@I-build-crafts
@I-build-crafts 26 күн бұрын
Hi Josh! Right off I have to say that your videos are great, detailed and clear. Thank you! I have a question that I am sure you know the answer to and one that I can't find an answer online. How many outgoing power feeds can I pull from an outlet using a pigtail? I am using 12/2 wire from a 20 amp outlet receptacles with a 20 amp breaker. Thanks for the help.
@Aug3r
@Aug3r 6 ай бұрын
I'm now going to hit the like button
@freewillieklr
@freewillieklr 2 ай бұрын
Super video but ,be aware of something easy to check deeper into.. Not sure if it was mentioned but worth checking into folks... i didn't hear the excellent laborer talk about the receptacle type/rating when using #12 wire with 20 amp circuit.. In Canada{maybe USA too?} standard wall receptacle plugs are only rated at 15 amps..{but there is a heavier/different 20 amp wall receptacle available at extra $$} .ie: if a 12 gauge wire is used with a 20 amp breaker the 15 amp receptacle would not be heavy enough for the power supply that could be pulled through the receptacle by power hungry shop tool{s} on the same wall receptacle.
@Chrissers2010
@Chrissers2010 6 ай бұрын
10:41 I don't believe you should "punch out the back of this box" with the needle nose. Those plastic tabs are intended to be pressed INTO the box with the Romex and grip and secure the Romex when it is inserted in the box. If you look closely at that tab, it has molded lines in it that are for gripping the Romex. Also, a lot of electricians like to run the outlet boxes in a garage up around 48" above the floor, that way if things like plywood (4 foot wide) lawn mower, gas gas, etc. are below the outlets.
@jamesflynn6984
@jamesflynn6984 Ай бұрын
Great Video! Thanks for the time and effort. Simpliefies a few things and picked up a few tricks. One question I have, is about planning and drawing your plans. Saw a few quick screen shots but nothing too detailed. Is there an App/Program you use to layout your electrical? Also, if anyone has suggestions for an easy to use Room/Garage layout and design, I'd love to hear. Looking for something I can scan or input dimensions and then be able to draw /drop in dimensions for items both ON WALLS as WELL as FLOOR FOOTPRINT. Limited space so I am hoping to use drop tables and a french cleat wall to optimize my space and give me a table/mitre saw feed station.
@BrianHurtt-uu1sk
@BrianHurtt-uu1sk 6 ай бұрын
Let me ask you when you did the branch circuitry in the summer kitchen did article 210.52 or 152.47slip your mind? It requires a minimum of TWO small appliance circuits in the kitchen I feel sorry for whoever is working in the kitchen start up a toaster oven and then turn on the blender and it blows the circuit
@NickFrom1228
@NickFrom1228 6 ай бұрын
Trick for installing boxes, if you have a large enough project to matter. Take a piece of decent 1/2" plywood and cut it to be the height of the top of the box to the floor. Cut a notch the size of the box. Screw or glue a stop blocks so that they line up with the outer edges of the box notch. You can now walk up to a stud, place this template against the stud using the stop blocks to position it, drop a box into the slot and nail it in. Goes super fast and makes everything really consistent. When you don't have to stop and measure, mark etc it can save a great deal of time if you do this a lot.
@tonybarkdull1199
@tonybarkdull1199 6 ай бұрын
Nice tutorial. Do you need to use staples when running wire above the rafters? Likewise in a crawl space, staples or drilling through the joists? I will be installing 4 exterior receptacles, GFCI, and runs will be in my crawl space.
@gailtaylor1636
@gailtaylor1636 6 ай бұрын
Can save tons of time by using WAGO connectors!!!
@emmannuelthomas8060
@emmannuelthomas8060 6 ай бұрын
Thanks. I learned a lot. Can you please do a front porch concrete staircase repair where concrete is chipping off? I asked a contractor for my house and price given was something I cannot afford.
@redmatrix
@redmatrix 7 ай бұрын
1:21:35 When labeling circuits, it's a good idea to note the cardinal location of area so that in the future, someone who (is not you) can know WHICH work station is number 1, and which one is number 2, etc. [IE: Workstation 1 (east) and Workstation 2 (west)] The same thing can be said for rooms in a house. Just because one uses the North middle room as an office, doesn't mean a new occupant will use it as such, which in turn might confuse an electrician in the future (for a little bit) when new occupant says they want the nursery to get an upgrade, but it's labeled as "office" on the panel. Just a tip, take it with a grain of salt.
@deadmanswife3625
@deadmanswife3625 7 ай бұрын
Some of us have it in our minds to think of the next person I think you shared a good tip. I like the way you said take it with a grain of salt at the end because you can't think of everything or we would be making these videos ourselves LOL
@adelinawarriner6259
@adelinawarriner6259 3 ай бұрын
I still don't know where the "tractor" circuit goes.. nothing in the house that we can find turns on or off when it's disabled
@RickL_was_here
@RickL_was_here 6 ай бұрын
If you're ever planning on actually doing work in the garage, you'll want a couple separate circuits. Depending on your vacuum system you might want that kept separate. Wi-Fi access points should be ceiling mounted when possible. Also, if you plan on a man cave, be sure to run a couple Cat6 to where your TV will go, cable is useless unless you want a separate cable box there. Either way, run the Cat6. Run a Cat6 to anywhere you think you might need one as well. Cat7/8 can be used as well but being a shop... meh. You can install one of those ugly white boxes on/in your wall or run the wire to a central, accessible spot (make sure there's a connection to where the main house modem is using DB wire). As a side note, I wonder how long it will be before they acknowledge running 14/2 to lighting, and those electrical boxes, is a waste....
@lespaul36
@lespaul36 5 ай бұрын
As an ex datacom/telecom/electrician person, I would go with Cat 5E. Easier to deal with, cheaper, and can handle most installs fine, unless you are running extremely fast hubs and servers. But, that my opinion.
@deezTX
@deezTX 4 ай бұрын
nice
@TheExcellentLaborer
@TheExcellentLaborer 4 ай бұрын
I appreciate that!
@loralkinney
@loralkinney 6 ай бұрын
using a 2-4 push (Ideal)wire connector will help a great deal in your box and not be so hard to deal with in a tight place and it's a lot faster!
@rickmaberry8761
@rickmaberry8761 3 ай бұрын
Damn your Smart. Thank you
@rudyrivera7426
@rudyrivera7426 6 ай бұрын
Great video! “ question! What type of wire to hook up a 240 plug?? In my shop “ keep them coming! 👌👍
@TheExcellentLaborer
@TheExcellentLaborer 6 ай бұрын
I am making a video about the 240 volt outlet and will have it posted next weekend. Stay tuned!
@LearnHowToWipeYaArse
@LearnHowToWipeYaArse 7 ай бұрын
Building codes, permits, inspections... Laughs in Montanan😂
@AndrewLumsden
@AndrewLumsden 6 ай бұрын
Dump the wire nuts and use WAGO connectors instead. Proven to be much safer, and a more reliable connection.
@jeremywilliams4493
@jeremywilliams4493 6 ай бұрын
Can you do a video of you installing the garage door and opener when you have time
@danpenry8899
@danpenry8899 6 ай бұрын
I have three outlets in my garage that are wired with 8g. For my welders and I used 12 g for everything else
@KA9DSL
@KA9DSL 6 ай бұрын
I used WAGO connectors for wiring my attached garage, much better than twist caps connections.
@michaelruiz4074
@michaelruiz4074 6 ай бұрын
Proper way to roll out romex is from the outside instead of the middle and when rolling out the Romex also step on it to keep it straight
@mikeransom1168
@mikeransom1168 6 ай бұрын
At 3:30 you mention copper crimp sleeves for tying together the grounds in the boxes. It might be useful to mention that you are using #14/WG and #12/WG in your introduction of the wire type you are using because somebody in your audience will have an OLD roll of Romex without the ground wire and not know the difference. Just a minor detail. Otherwise, good on ya.
@tiffyb1088
@tiffyb1088 6 ай бұрын
I hope to never play a "with that being said" drinking game. Haha Neat to watch you work, though.
@duanesamuelson2256
@duanesamuelson2256 6 ай бұрын
Left out some rather important aspects. You save money long term by using 12ga for 15 amp circuits and 10ga for 20 amp..line losses are less. It use to be about 3 years use to pay off the difference in cost, not sure of the current time. The minimum is for safety, and used commercially due to cost. That doesn't make it the best long term. There's also length of run losses. Voltage drop can have a significant impact on tool life (lower voltage requires higher amps for the same work)
@peterchow4577
@peterchow4577 6 ай бұрын
Great video, I have a question, what is the maximum receptacle per breaker? Thanks
@TheExcellentLaborer
@TheExcellentLaborer 6 ай бұрын
That is a great question! I personally try not to put more than 10 on a circuit. It all depends on what you were going to be doing on that circuit. Obviously, if you are going to be using something that drawing a lot of amps, then you only want one receptacle on that circuit. I hope that helps!
@BearStar1
@BearStar1 5 ай бұрын
Those recessed can lights are old school now days ! Everyone is using recessed LED pan lights now days in new construction and remodels
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,1 МЛН
Balloon Pop Racing Is INTENSE!!!
01:00
A4
Рет қаралды 17 МЛН
Let's all try it too‼︎#magic#tenge
00:26
Nonomen ノノメン
Рет қаралды 54 МЛН
Did you find it?! 🤔✨✍️ #funnyart
00:11
Artistomg
Рет қаралды 114 МЛН
How To Wire A Room For Electricity - Bedroom Wiring Rough In
30:17
The Excellent Laborer
Рет қаралды 1,2 МЛН
How To Wire A Garage - Receptacles, Switches, Lights, and Fan Installation!
53:34
10 Mistakes EVERYONE Makes When Doing DIY Electrics!💥
11:56
Artisan Electrics
Рет қаралды 144 М.
How To Wire A Main Electrical Panel - Start To Finish! NEATLY And VERY DETAILED
43:50
The Excellent Laborer
Рет қаралды 2,8 МЛН
How NOT to Wire Light Switches in 2024 (New Rules)
15:21
Backyard Maine
Рет қаралды 730 М.
How To Add An Outlet To A Finished Wall
10:51
Everyday Home Repairs
Рет қаралды 10 МЛН
Understanding Wire Gauges | Ask This Old House
4:52
This Old House
Рет қаралды 315 М.
How to use a multimeter like a pro, the ultimate guide
12:55
James Gatlin
Рет қаралды 1,4 МЛН
Useful Tools and Smart Gadgets For Cute Kids 💕 #gadgets
0:35
Meow-some! Reacts
Рет қаралды 12 МЛН
Best transport for daughter #shorts by Tsuriki Show
0:12
Tsuriki Show
Рет қаралды 4,4 МЛН