Navien Combi Boiler System With 3 Zone Valves

  Рет қаралды 3,057

Jim Speranza

Jim Speranza

Күн бұрын

Пікірлер: 19
@leonginorivera8309
@leonginorivera8309 Ай бұрын
Great installation loops , I love it .
@RSWarriorLuv2LafMcc
@RSWarriorLuv2LafMcc 9 ай бұрын
Nice little set up! Thanks for the video.
@jerrydelvalle973
@jerrydelvalle973 7 ай бұрын
Great video! I noticed you didn’t use temperature sensors on the return and supply for the heating system, like you have done on other systems. Is there a particular reason?
@JimSperanza
@JimSperanza 7 ай бұрын
The supply and return sensors are used for the variable speed delta T circulator. This system uses a fixed speed circulator.
@stevenmahone3511
@stevenmahone3511 9 ай бұрын
Jim, looks great. What is the total weight of the system mounted on the plywood? Two people can 'easily' mount it?
@JimSperanza
@JimSperanza 9 ай бұрын
About 150 lbs. Yes easily can mount it with two people. Best way is to use a temporary 2x4 ledger board to rest the bottom of the system on until the plywood is lagged to the wall studs. Then the bottom 2x4 can be removed.
@JosephSaeteros-r9j
@JosephSaeteros-r9j 4 ай бұрын
I have the same piping i sill like to know hoe to wiring the zone valves
@erwinperez2889
@erwinperez2889 Ай бұрын
We're do you hook up the fresh water in the system?
@JimSperanza
@JimSperanza Ай бұрын
@@erwinperez2889 there is an auto fill connection on the bottom.
@BeeBombard
@BeeBombard 4 ай бұрын
Just curious why did you cap the top of each vertical run?
@JimSperanza
@JimSperanza 4 ай бұрын
@BeeBombard allows for future zones to be added. Some customers want that option.
@guess313
@guess313 2 ай бұрын
when usig hot water, does it stop heating - Is there any boiler which heats up both at the same time, hot water and baseboard heating
@JimSperanza
@JimSperanza 2 ай бұрын
@guess313 all combis work this way
@Djbigb8092
@Djbigb8092 3 ай бұрын
So I just set up my combi system exactly like this. When I look in the book, it only shows 2 wires needing to be connected to the sentry zone valve(common and normally open). My sentry zone valve states it’s normally closed. It looks like you have more than 2 wires connected to the valve. What else should be connected?
@Djbigb8092
@Djbigb8092 3 ай бұрын
I only have 2 zones by the way and both stats are only 2 wire setups
@JimSperanza
@JimSperanza 3 ай бұрын
@Djbigb8092 you only need two wires when connecting to the navien.
@Djbigb8092
@Djbigb8092 3 ай бұрын
@@JimSperanza that’s what I thought. Looks like you have more than 3 connected which I started to wonder. In the book, it states sentry should connect to normally open, my valves are actually normally closed so I’m assuming that I use 2 wire and just do common/nc, correct?
@karriem3261
@karriem3261 9 ай бұрын
What size and model is that boiler?
@JimSperanza
@JimSperanza 9 ай бұрын
NCB-240/110H
Navien NFC-250/200 Combi-Boiler Retrofit #8
28:53
Canuck Mechanical
Рет қаралды 19 М.
Jba upper control arms on 07-21 Toyota Tundra
21:00
dirtydeedsindustries
Рет қаралды 13 М.
Война Семей - ВСЕ СЕРИИ, 1 сезон (серии 1-20)
7:40:31
Семейные Сериалы
Рет қаралды 1,6 МЛН
TUFFTRAC Over Tyre Tracks
2:12
TKV Group
Рет қаралды 11 М.
Combi Boiler Piping Explained
7:41
Jersey Mike HVAC
Рет қаралды 21 М.
I've Never Seen ANYTHING Like This | Combi Boiler Install
9:53
Roger Wakefield Plumbing Education
Рет қаралды 74 М.
Navien NCB-190/60H two zone combination boiler & tankless install
4:17
DiBacco Plumbing, Heating & Cooling
Рет қаралды 10 М.
Zone Valves vs. Circulators; Which Is Better?
1:02:31
Taco Comfort Solutions
Рет қаралды 20 М.
Navien NFC-175 combi Boiler Retrofit #1
10:31
Canuck Mechanical
Рет қаралды 93 М.
How To Wire a System Circulator to a Taco Zone Valve Control (ZVC)
12:24
Taco Comfort Solutions
Рет қаралды 308 М.
Combi Boiler with Two Heating Zones, 230V Switching
15:26
John Ward (jwflame)
Рет қаралды 89 М.