How to Complete a Successful Central AC with Furnace Preventative Maintenance Service Call

  Рет қаралды 11,130

Mikey Pipes - Pipe Doctor Plumbing & Heating & Air

Mikey Pipes - Pipe Doctor Plumbing & Heating & Air

2 жыл бұрын

Step by step instructional guide on how to successfully complete an annual central AC preventive maintenance service call on a condenser, evaporator coil and gas furnace.
Interested in an easy to use mobile dispatching, invoicing and payment receiving option? I've been using ServicePal for almost 10 years. Check it out here: app.servicepal.com/account/si...
Please support this channel and Mikey Pipes and consider the following…
Pipe Doctor & Bosch short sleeve shirts are available in Medium, Large & 2XL
Minimum donation of $23 is appreciated
Pipe Doctor FlexFit Embroidered Caps
Minimum donation of $37 is appreciated
(If you are international - please add a minimum of $40 for shipping/postage)
Shopping on Amazon? Please use my referral link amzn.to/2PjjS4v
I love Bombas socks. And you will too: You should get $25 off instantly on your first purchase at Bombas. Don't forget to use my referral link: refer.bombas.com/x/dbXDBJ
Sticker Requests:
Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
Name
Address
City, State, Zip
Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
PayPal is: office@pipedoc.net
Venmo: @PipeDoctor
CashApp: $mikeypipesny
Want to send a love letter, note or gift? Our mailing address is:
Mikey Pipes
C/O Pipe Doctor Plumbing
80 E Hawthorne Ave
Valley Stream, NY 11580
#acmaintenance #hvac #mikeypipes

Пікірлер: 50
@rcald-gz5jd
@rcald-gz5jd 2 жыл бұрын
I better see basement cricket in future episodes... soon. I'll be watching for that. =P
@Jon-hx7pe
@Jon-hx7pe 2 жыл бұрын
if the blower motor is a psc, amps go up when the access panel is removed - motor unloads as static goes down, loads as static increases. ecm is different due to constant torque or direct airflow compensation.
@kyndalldecker9115
@kyndalldecker9115 2 жыл бұрын
Best pic, we appreciate this post! 💗
@pawelkolodziej4210
@pawelkolodziej4210 2 жыл бұрын
I like Bears slippers
@patriciashelton9184
@patriciashelton9184 2 жыл бұрын
Absolutely love💕 both you and your Shares Many thanks
@alayahcoleman9993
@alayahcoleman9993 2 жыл бұрын
It's interesting not just Supercool!
@charliewest5377
@charliewest5377 2 жыл бұрын
Great Picture
@scottvolage1752
@scottvolage1752 2 жыл бұрын
Let's go #LoveBosch
@tabithavaughan6343
@tabithavaughan6343 2 жыл бұрын
stupendaaaa,Super ! You are so striking!☀
@chadschafer1723
@chadschafer1723 2 жыл бұрын
Checking voltage drop across the contactor is also a quick check that can show issues
@beverlydentdent2860
@beverlydentdent2860 2 жыл бұрын
OoOoHhh I like this one😍😍🌹
@Twnty-ui4ev
@Twnty-ui4ev 2 жыл бұрын
Mikey pipes let’s go
@thefathvacguy6341
@thefathvacguy6341 2 жыл бұрын
Omg basement cricket gonna have his own channel!
@eddiew.6485
@eddiew.6485 2 жыл бұрын
"If you ain't testing, your guessing....." Nice Video, as always Mikey!
@geraldfoon6283
@geraldfoon6283 2 жыл бұрын
Just had annual PM on my 3 HVAC units today. You did 2 things they did not do which is: 1. check the contactor coil resistance 2. treat the condensate water. Everything else was the same. FYI: They found on one unit the wire insulation near the spade connector wires to the capacitor had started to degrade leaving the wire exposed. Maybe the extra-long AC run times in 100+ degree temps with heat index temps around 108 we've had for the last week or two had something to do with melting the wire insulation. Oh, the technician was a female who finished HVAC school about 3 years ago.
@patmcnally6
@patmcnally6 2 жыл бұрын
She did pretty Good just a Couple of add ons. She Found the wire thats being observant of her Surroundings. 👍🏻👍🏻👍🏻👍🏻
@smitty1715
@smitty1715 2 жыл бұрын
Very nice video Mr. Pipes
@throttlebottle5906
@throttlebottle5906 2 жыл бұрын
if labeling capacitor/wires, you're better of using BL = Blue. BK = Black. it's that way in many wiring schematics and board printing and other labeling. ** I forgot BR = Brown
@KavinSBS
@KavinSBS 2 жыл бұрын
I like it Thanks Mike
@duramusmosley5530
@duramusmosley5530 2 жыл бұрын
In general, on installs, do y'all always run a new line set, or is it an as needed thing?
@kkovler1
@kkovler1 2 жыл бұрын
Before I listened to your channel I would never test capacitors unless they might be bad, causing a problem.
@joebal9044
@joebal9044 2 жыл бұрын
Why is there a condensate trap since the evap is on the positive side?
@eliaslemus4037
@eliaslemus4037 2 жыл бұрын
U don't do a carbon dioxide test on your PM Bro?
@swaterman08
@swaterman08 2 жыл бұрын
I called a guy one time for my company, he attempted to bill us his hourly rate plus the same rate for his helper so x2
@chuckquinn8026
@chuckquinn8026 2 жыл бұрын
Mikey, can you use the secondary drain port to put the tablets into the drain pan to save time?
@chuckquinn8026
@chuckquinn8026 2 жыл бұрын
@@PipeDoctor understand. I was just curious if it’s possible
@ryanbreeze2312
@ryanbreeze2312 2 жыл бұрын
Unexpected smashing pumpkins
@robertzacks3002
@robertzacks3002 2 жыл бұрын
B for Blue and B for Brown....I'm so confused....I love your channel and your way of teaching very effective. Thanks!
@dalekronk496
@dalekronk496 2 жыл бұрын
Only thing I do that is different is I test pressures and amps of the condenser fan and compressor
@dalekronk496
@dalekronk496 2 жыл бұрын
@@PipeDoctor your good I figured you probably did. But yeah I take about a hour to do a maintenance service.
@michaelkierpaul2037
@michaelkierpaul2037 2 жыл бұрын
$20.00 if Chris eats the basement cricket. 😁 . Great video Mikey pipes.
@mph5896
@mph5896 2 жыл бұрын
Leave basement cricket there for next year.
@scotts4125
@scotts4125 2 жыл бұрын
@@PipeDoctor Naw this one is better. $40 if he poops it out in the pool!
@jph77
@jph77 2 жыл бұрын
More water heater service calls please.
@inthedarkwoods2022
@inthedarkwoods2022 2 жыл бұрын
You should include the price of the job
@stephwaylonwells3218
@stephwaylonwells3218 2 жыл бұрын
👍
@Cmize420
@Cmize420 2 жыл бұрын
That furnace/evap set up isn’t supposed to have a drain trap unless it’s vented prior to….. per installation manual
@benjamintimmins1656
@benjamintimmins1656 2 жыл бұрын
Mikey you should of opened up the door to show chris the amps. They actually go UP and fall as you put the door on! With an ECM motor its opposite...
@marconantel7735
@marconantel7735 2 жыл бұрын
@@PipeDoctor sippy cup?! Hillarius but trainable?
@benjamintimmins1656
@benjamintimmins1656 2 жыл бұрын
@@PipeDoctor please no sippy cup...It would be cool if you brought back Kelvin!
@wayneguy6043
@wayneguy6043 2 жыл бұрын
If you put b for blue and b for brown……..
@tjlovesrachel
@tjlovesrachel 2 ай бұрын
He needs some longer pants😂😂😂😂
@idacarls851
@idacarls851 2 жыл бұрын
Hello👋 fab
@prestigemechanical3600
@prestigemechanical3600 2 жыл бұрын
Those capacitors “almost all capacitors that come with condensing units” are junk. Even on new installs I remove them and use replace them with the USA made ones. I quit pulling the leads to test them it’s more accurate to test them while the unit is running plus it is faster.
@mph5896
@mph5896 2 жыл бұрын
Mine is on the original after 6 years. New one sitting on the shelf if I need it along with an igniter, and flame sensor.
@berthaaustin6457
@berthaaustin6457 2 жыл бұрын
Superhot
@teeg3275
@teeg3275 2 жыл бұрын
Those color coded icp caps are junk
@wayneguy6043
@wayneguy6043 2 жыл бұрын
Jew plumber……yikes….expensive
How to Properly Service and Perform Annual Maintenance on a Central AC Outdoor Condenser
23:54
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 18 М.
Backyard Custom Pool Fire & Water Features Repaired Jandy Grand Effects Ignition Module Replaced
14:36
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 24
Sigma Kid Hair #funny #sigma #comedy
00:33
CRAZY GREAPA
Рет қаралды 33 МЛН
WHY CAPACITORS FAIL in Air Conditioners! Watch it Break!
9:45
AC Service Tech LLC
Рет қаралды 1,4 МЛН
JFK Airport Hotel Not Cooling from Daikin Ducted Mini Split System
12:16
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 13 М.
Emergency Central AC Service Call July 4th Bosch IDS 2.0 Isn’t Working Thermostat Is Dead
9:03
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 16 М.
How To Operate HVAC Controls On An Airstream
5:32
Airstream of DFW
Рет қаралды 8 М.
How to Properly Perform Annual Service and Maintenance on a Central AC System
28:24
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 400 М.
Installing Bosch IDS 2.0 Heat Pump System using the Accutools TruBlu Evacuation Kit and BluVac+ Pro
42:26
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 46 М.
Central AC Isn’t Working - Blowing Hot Air Diagnosed & Repaired
15:13
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 4,3 М.
Why an Air Conditioner Coil FREEZES! Examples, Procedures, Troubleshooting!
11:34
The Corvette ZR1's Engine Is Absolutely Insane - 1,000+ Horsepower!
15:45
Engineering Explained
Рет қаралды 27 М.
ДОМИК ИЗ АРБУЗА #юмор #cat #топ
0:40
Лайки Like
Рет қаралды 2,1 МЛН
PRADO 250 - классная машина!
0:28
Тарасов Auto
Рет қаралды 3,1 МЛН
One moment can change your life ✨🔄
0:32
A4
Рет қаралды 34 МЛН