Thank you for the video Excellent it gives us full confidence to work Alpha boilers.
@AlphaHeatingInnovation3 жыл бұрын
Thank you so much!
@robbie2awesome Жыл бұрын
what a complete carry on, seriously who designed this, I'll guarantee it was some button pusher in an office and not a practicing service and repair tech.
@thelegand1 Жыл бұрын
Replacing parts in this boiler is super easy but calibrating the gas valve really does let it down. I like how it can be done digitally but not when it’s this complicated, who thought this was a better idea than spending a few minutes turning a couple of screws? Not to mention the amount of water and gas used in this process.
@siouxhartley43236 жыл бұрын
great video helped wonderfully thanks!
@davidwaldron62596 жыл бұрын
Great video , but why not show readings on analyser
@kevinstevens9183 жыл бұрын
Hi.just got a static caravan with the alpha intec 28x...when i push button to turn on winter mode..the boiler motor or fan etc runs .i left it on in this mode for good few hours and it dont stop running.should this do that????.central heating works fine with thermostat etc..its been checked serviced before it was handed over..many thanks
@AlphaHeatingInnovation3 жыл бұрын
Hi Kevin, thanks for your enquiry. If there’s no demand (i.e. from room thermostat) the boiler should come to a complete stop. If the caravan is newly owned, we’d suggest speaking to the vendor to get it looked at by a heating engineer.
@kevinstevens9183 жыл бұрын
Many thanks for reply.yes i shall tell them and thought it wasnt rite..all the best
@jamespenn24905 жыл бұрын
On a fast calibration of alpha in tec228xe boiler goes to 90 knocks off then fires again same thing with tap open won't hold steady help
@AlphaHeatingInnovation5 жыл бұрын
Our technical team would be more than happy to help. You can call them on 0344 871 8764 and they'll talk you through the process.
@beawalker26523 жыл бұрын
How do I turn on the hot water?
@AlphaHeatingInnovation2 жыл бұрын
Hi Bea. Please call the Helpline team on 03448718764 and we'll happily assist with your query.
@Lord.Voldemort3652 жыл бұрын
Hi, my boiler has a red flashing light and radiheaters won't heat up?
@AlphaHeatingInnovation2 жыл бұрын
Hi Hina. Please call our Helpline on 03448718764, one of our Helpline technicians will be able to assist.
@happyslapper072 жыл бұрын
What causes E96 fault
@AlphaHeatingInnovation2 жыл бұрын
Hi Johnny. An E96 is an airflow issue so would recommend getting it looked at by a GasSafe engineer or speaking with our customer service team.