Only 22 seer2. ?
@mootantes
@mootantes 4 күн бұрын
smart move
@37gdog
@37gdog 6 күн бұрын
What refrigerant are these charged with? i would be shocked if those fittings don't leak if it's R410.
@airspool
@airspool 5 күн бұрын
Prepare to be in shock! They're pricey, but worth it.
@user-wg6gd8lg4b
@user-wg6gd8lg4b 6 күн бұрын
Can you please upload a video with the full process and full step by step procedure including attaching hoses, opening or closing valves how you set up your gauges etc and removing the hoses etc. Like thank you so much for sharing this but I still have a lot of questions after this video. I have a multi zone mini split with two heads. Do I run both for the pump down or is one on okay?
@airspool
@airspool 6 күн бұрын
JD, yes, the process is possible with multi head unit. Check some previous comment postings on how to do it for your setup, because there are a few. Connect to the service valve on the biggest indoor unit, if one is bigger than any others.
@michaelbeall7754
@michaelbeall7754 13 сағат бұрын
This may sound stupid but is the gauge on during the line vac or closed
@AlwaysSlimShadyBro
@AlwaysSlimShadyBro 7 күн бұрын
Warranty...
@airspool
@airspool 6 күн бұрын
Airspool offers a 1-year buy-and-try plus 3-year parts and 5-year compressor warranty.
@martinwinlow
@martinwinlow 9 күн бұрын
Might be worth mentioning that (I assume) the min-split's compressor is doing the work here... no external vacuum pump needed... Is that correct?
@airspool
@airspool 9 күн бұрын
Correct!
@a3_a3
@a3_a3 13 күн бұрын
any discount if we buy/pickup locally?
@airspool
@airspool 12 күн бұрын
No extra discount, but you'll get our extra local love and attention and a tour of the joint. In general, shipping should be less than $100 to wherever you are in the lower 48. We subsidize this heavily.
@hiyou2587
@hiyou2587 13 күн бұрын
I've only had my unit for 2 weeks and so far love it. It's very not difficult to install. I don't use the E word, don't want to jinx it. When I talked about it at work 3 other guys are talking seriously about installing 1 or more themselves.
@Lst2ltdwn
@Lst2ltdwn 15 күн бұрын
What are the inputs of the solar array, needed, it says 1400-1500 watts, nothing about voltage input?
@airspool
@airspool 14 күн бұрын
Hi, the voltage should take care of itself for this amount of wattage, but just make sure that the voltage open circuit, or Voc, from the back of the unit is between 80 and 380 volts when you add up all your panels.
@bonexsher
@bonexsher 15 күн бұрын
A/C company did a crappy job capping off duct work 😮‍💨
@airspool
@airspool 14 күн бұрын
Yes. Well, we're just feeding into the ductwork as an access point to downstairs. These units are all ductless, so just need to run the line set through the old duct.
@angstrommanagement3016
@angstrommanagement3016 16 күн бұрын
Great video, super simple, HVAC folks dont want ahyone to see this because they thrive on freon recovery and replacement services, winning!
@user-ol5rj8qn9o
@user-ol5rj8qn9o 18 күн бұрын
Nice video. I need to wait to see people's feedback before purchasing. Don't know what the track record will be yet for these units. What is the start power (amps) requirement for the Airspool comressor unit?
@airspool
@airspool 18 күн бұрын
Hey, the compressor has no start power like a normal on-off compressor. It's variable speed inverter compressor, so it starts very slowly. It needs less power in the beginning than it does when it's running. It ramps up to between 300 W and 1200 watts, depending on the outside air temperature and your settings for the unit and your indoor air temperature. And yes, we only have a few people who have reviewed this so far, because it's a new product, but you'll see our standard ms-12 as a lot of reviews, and this one has great reviews so far that you can find. You'll also find a couple of users that have installed this and have been made videos.
@user-ol5rj8qn9o
@user-ol5rj8qn9o 18 күн бұрын
@@airspool Thank you for your quick reply! I installed a Hyper soft-start on my main ac unit this season and it too provides a ramp up of current, but only on startup. My start amps went from 77A to 22A. My unit however does not provide for the variable run current as the Airspool though. That's a "really cool" unit there. Norm
@davidjackson552
@davidjackson552 20 күн бұрын
How is this 12,000 BTU as it is advertised? If it is 12,000 BTU per hour then that is by definition a rate of energy (power) of around 3500 watts = 1 ton = 12,000 BTU/hr.
@yamafanboy
@yamafanboy 20 күн бұрын
What is the minimum recommended solar input voltage and amperage for this unit? I saw in another video that the compressor will start to run at a minimum of 300 watts but I can't imagine it will do much with 300W of input power. I would like to use the least number of panels to run the unit while at the same time still requiring the least amount of grid power consumption. (as close to off grid as possible is my goal)
@airspool
@airspool 20 күн бұрын
The input voltage needs to be between 80 volt and 380 volts direct current. And shoot for around 1,500 w. This tends to be a pretty optimized amount to keep the unit running off-grid during the daytime. Yes, the compressor will run on 300 w, but not fast. That's just the starting speed. It's a variable compressor so it will speed up if you give it more power. And as it reaches the set point, it will slow down automatically. If there is a large cooling load, and it's summertime, the unit needs for power, since the compressor needs more power in the summer. So, around 9:02 1200 watts and the hottest part of summer or coldest part of winter, and around 500 to 800 W in the fall and spring time when it's near the outdoor air temperature.
@averyalexander2303
@averyalexander2303 20 күн бұрын
Too me, R32 seems to be the better option. It's cheaper and not patented and from what I can find, it's generally more efficient than R454b. I haven't found any data on whether R32 or R454b is more flammable, they seem about equal from what I can tell. Single component refrigerants are easier to work with and recycle since they won't fractionate. Other than the somewhat lower GWP, I'm just not seeing the benefit of R454b. The lower GWP isn't even a benefit if it's less efficient and results in higher power consumption.
@lastofthemohicans1
@lastofthemohicans1 23 күн бұрын
Is the unit running when you do this?
@airspool
@airspool 20 күн бұрын
Yes. The compressor motor is used to pull the refrigerant back into itself.
@RJSOBO88
@RJSOBO88 24 күн бұрын
Wrong crimping tool and bad advice + poor installation you have just demonstrated. Trust me, I've replaced over 1000 PV connectors in residential, commercial and Utility solar.
@airspool
@airspool 20 күн бұрын
RJS, do you have a video for this? It would be useful for our users.
@RJSOBO88
@RJSOBO88 19 күн бұрын
@@airspool kzbin.info/www/bejne/eoasgJmLm9F3bqMsi=WuVJ3jiY3_7YLaIy
@RJSOBO88
@RJSOBO88 19 күн бұрын
@@airspool the manufacturer of the DC connector should provide this data. FYI, many of the connectors found on Amazon are cheap plastic and will not last past 7 years and depending on how DC conductors are managed, it may start a fire.
@RJSOBO88
@RJSOBO88 19 күн бұрын
@@airspool the manufacturer of the DC connector should provide this data. FYI, many of the connectors found on Amazon are cheap plastic and will not last past 7 years and depending on how DC conductors are managed, it may start a fire.
@Epicwisdom600
@Epicwisdom600 24 күн бұрын
kzbin.info/www/bejne/mHvJo36Eh5h-aM0si=_H0doG2kNnzkQ2FM
@marthabetan
@marthabetan 25 күн бұрын
Where can you order
@airspool
@airspool 24 күн бұрын
Hi Martha, that's a type of question we like! shop.airspool.com/
@AnnLippert1
@AnnLippert1 27 күн бұрын
when you connected them should you have used Nylog?
@airspool
@airspool 27 күн бұрын
Ah, the great debate.
@ricardomarmol1257
@ricardomarmol1257 28 күн бұрын
Love it. Great idea.
@ricardomarmol1257
@ricardomarmol1257 28 күн бұрын
Do you have or sell bigger unit .orher than the 12000BTU And longe line set than 10 ft?
@airspool
@airspool 27 күн бұрын
We have 18,000 BTU and 24,000 btu, but they are not energy star rated yet, so get in touch for the details. And we can customize the line set on the quick and easy units. For our non-DIY unit, supplyhouse.com
@GardenForaged
@GardenForaged 29 күн бұрын
This would be great for central America! People need AC but the electricity is so expensive. What a cool product
@airspool
@airspool 29 күн бұрын
Yes, it's perfect for off grid. You can imagine in New Delhi, for instance, yesterday when it's 126°, and power is sketchy, this is a good solution there, too.
@miamiSincar
@miamiSincar Ай бұрын
nice thank youuuuuu
@MikeStrine_RoatanStrineWay
@MikeStrine_RoatanStrineWay Ай бұрын
Can the hole (for going through the wall to the outside) be offset to the right of the inside unit? There appears to be a 'punch-out' or scored area on the right end of the unit on Page 8 of the installation instructions. I want to mount it above a window, but to avoid the header, and studs in the wall, can bring it out about 10" - 11" outside of the unit, before taking the 90* bend to go through the wall? We have a 2"x4" wood wall construction, so I believe from the bend behind the unit, about 12-13" to the right, then bending outside 5", then downward. Will the Quick 'n' Easy line pigtail be enough to get it outside to connect? Thank You - (getting ready to order ~ save me one!).
@airspool
@airspool Ай бұрын
Hi Mike, yes, you can punch out to the right, no problem. Will do the final measurements to make sure that's also viable for the quick and easy, since normally that would go straight through the wall. Or we can customize the quick and easy to put the valves on the outdoor unit possibly if necessary. We'll discuss it.
@reedjacksonmaccom
@reedjacksonmaccom Ай бұрын
I want one. I just checked my monthly elex bill here in my 1200 sq ft single story 1960 insulated house in Sacramento and for four hot months the bill soars to 150 avg, else its 55 avg the other 8 months. so if I get the ez kit and source 2000 watts of used panels from those places where you gotta order online and then drive 20 miles to a distribution point on the delivery/pickup date I could probably roi in what 6 years. AAANNDDD, run my house temps more comfortabler…. cuz to keep the $$$ lower I do quite a few 80° days indoors
@airspool
@airspool Ай бұрын
Yes, in Sacramento, the savings are huge, because PG&E just keeps on gouging and the panel price keeps on coming lower. Check locally at Greentech Tenewable Sacramento. They have some panels and a lot of places under $0.35/watt, we're finding. And you only need 1500 watts. No need to do 2000. So for around 5 or $600 in panels, you'll be able to run for the next 25 years for free during the day there. Beats paying 35 cents a kilowatt-hour.
@reedjacksonmaccom
@reedjacksonmaccom Ай бұрын
I’m in SMUD but, you’re right peak hours 5-8PM the rate is .35
@Iamkab
@Iamkab Ай бұрын
Your video starts with the gauge already connected to the service valve. When I try to connect my gauge it starts shooting out quite a bit of coolant before I can even get it screwed on fully. What am I doing wrong?
@airspool
@airspool Ай бұрын
Well, good gauges should screw on a bit before the Schrader starts pushing down. Search for environmentally friendly gauges, and those will help you save both money and save the environment from keeping refrigerant from being released.
@Iamkab
@Iamkab 27 күн бұрын
Thank you!
@HAWAYP
@HAWAYP Ай бұрын
Hi, Can I use a digital micron gauge instead of the standard pressure gauge. If so, what reading should I expect from the micron valve (in microns). Thanks
@airspool
@airspool Ай бұрын
www.convertunits.com/from/PSI/to/micron+mercury yes, take it down to 1000 microns.
@gregorystrompolos3382
@gregorystrompolos3382 Ай бұрын
Great video, thanks! I accidentally left a valve on my vacuum pump open when releasing refrigerant in the liquid line during setup, and lost a bunch of pressure. I tried running it anyway and the liquid line is icing. Think this will help, or do I need to just start over? Many thanks!
@airspool
@airspool Ай бұрын
It sounds like you really just need to add some refrigerant. No need to go through this procedure.
@strompolos
@strompolos Ай бұрын
@@airspoolthanks for the reply! Made my day. I believe there is also a leak in the liquid line though. So I’m going to do this trick, change/fix the line, vacuum the lines again, then re release the refrigerant.
@codetech5598
@codetech5598 Ай бұрын
What voltage does the hybrid unit expect from the solar panels?
@airspool
@airspool Ай бұрын
It needs between 80 volts and 380 volts of DC power from the solar panels. And then, if you want to plug in the alternating current, it needs from 110 volts to 240 volts for that. Solar will always be prioritized.
@user-pw1mh1fu9j
@user-pw1mh1fu9j Ай бұрын
I have a Daikin 4 ton multi port with 2 indoor units. 1 indoor unit cools great. The other does not. I think I had a leak and may have low refrigerant. Can I use this process in your video or do I need to recover and vac the system?
@airspool
@airspool Ай бұрын
Would need to turn both zones on cooling, then follow the steps, both valves need to be closed on the high side , the when at 0 on the low side. There are some other comments further down in this list, too, that talk about multi-zone.
@airspool
@airspool Ай бұрын
There is an electric solinoid valve for that circuit that opens on demand. However. The whole system would be affected when both zones are calling for cooling, not just one. We would almost be leaning towards a wiring issue that isn't opening the second zone valve.
@JaredJanhsen
@JaredJanhsen Ай бұрын
I've seen this king valve trick used on larger central units. I didn't know if it would work for mini-splits as well. Very useful tip. I was wondering if I'd have to shell out for a gas'n'go if my mini split ever had to come off the wall for siding repair/replacement.
@willembornman436
@willembornman436 Ай бұрын
Great advise ….thanks....What mode is this done in, Cooling or Heating mode?
@airspool
@airspool Ай бұрын
Always in cooling mode.
@user-jy6bl2ts7p
@user-jy6bl2ts7p Ай бұрын
Engineers who design these heads need to lose their jobs for not making these properly accessible. Typical.😊
@HAWAYP
@HAWAYP Ай бұрын
Hi, Thank you for the video. Quick question, can I do this for a four zone heat-pump, there is only one line set (one high and one low) for all the zones flow. I assume I have to turn on all units for the vacuum process, and to turn off all units at the same time I will use the circuit breaker from the main supply. Please correct me if I am wrong. Thank you again.
@airspool
@airspool Ай бұрын
Yes, and for the details, check some of the earlier comments from a year ago or something. There are some other people that also had multi-zone units with some other questions.
@MikeStrine_RoatanStrineWay
@MikeStrine_RoatanStrineWay Ай бұрын
What is the measurement from the center point, to the spot to drill the hole? It's 7.25" from the screw, but what is the measurement from the center? - (I need to check the placement for the header & studs for mounting above a window) - Thank You
@airspool
@airspool Ай бұрын
Hi Mike, there's actually room for improvement in this video, so we need to figure out how to write over a video and re-release this. The 7.25 in will work, but it's better to do 6.5 in from the right hand hole, or 6.75 in from the left hand hole. That gives you a little bit more room for the indoor unit to cover the whole without it being too close. Go to airspool.com/install for the details. And from the center, add 7 and 5/8 in to either of these two figures. That is, it's 7 and 5/8 in from the center to either of the holes on the left or right hand side of the mounting bracket.
@RF1octane
@RF1octane Ай бұрын
Maybe better audio and a more of a complex set up from start to finish would make this video perfect
@airspool
@airspool Ай бұрын
Likely.
@user-cc2qh9jx7u
@user-cc2qh9jx7u Ай бұрын
Just leave it on cool mode those systems use minimal power lees then a stand or ceiling fan actually
@airspool
@airspool Ай бұрын
Well, in general, ceiling fans are around 75 watts, and many splits need around 500 to 1,000 watts to run the compressor, depending on the speed of the compressor or if it's an inverter compressor. When mini splits are in fan mode, usually that's only around 20 watts.
@user-cc2qh9jx7u
@user-cc2qh9jx7u Ай бұрын
You have to turn the laser mode off o. The thermometer and just let it scan to get the actual room temperature using the laser is only to get temperature on service
@wildwestunlimited
@wildwestunlimited Ай бұрын
I loooooooooove my Airspool mini splits!! I installed 3 of them in my home here in az….. no more HUGE electricity bills! All cool air comes from solar!! HIGHLY RECOMMEND!!
@airspool
@airspool Ай бұрын
Big smiles over here upon hearing this news!
@grahamjohnson4702
@grahamjohnson4702 Ай бұрын
Can this have a battery connected for nighttime running off grid.
@airspool
@airspool Ай бұрын
Yes. Just plug it into your inverter for nighttime. Theoretically, you could have the same voltage as the system needs for your batteries, but as of now, it's probably a lot more practical to just plug into your inverter which is fed off of your batteries.
@AliRehmani-sm3qy
@AliRehmani-sm3qy Ай бұрын
Can I run my DC inverter ac on solar panels directly without any thing else?
@user-pr5rl1nl6q
@user-pr5rl1nl6q Ай бұрын
its hard to believe united states still carries any decent image for the World to remember
@airspool
@airspool Ай бұрын
Meow?
@kennethoh6928
@kennethoh6928 Ай бұрын
I bought a single manifold gauge. Do I plug or seal off the inlet that’s not being used for this?
@airspool
@airspool Ай бұрын
A single manifold set would only have one port that should be controlled by the valves at at the ends, as long as those valves are closed , shouldn't need to cap anything as the low side hose will go straight to the low side gauge.
@TaylorSmith-ex8nj
@TaylorSmith-ex8nj Ай бұрын
Valves are closed tight but when i break open the unions for the insode coil i still get hissing?
@airspool
@airspool Ай бұрын
The high side valve gets closed 1st the the low side valve gets closed when the gauge gets to zero. So, potentially, the compressor could pull enough to make the lines have a bit of a vacuum, but if you disconnect under these circumstances, the hissing will only be for a split second. If there's still refrigerant in the lines, that's high pressure, that will stay hissing for a while and be a very scary sound as you're losing your refrigerant as you disconnect. If you did the procedure correctly, all the refrigerant should be in the compressor.
@chadbrooks9029
@chadbrooks9029 2 ай бұрын
So leave power on?
@airspool
@airspool Ай бұрын
Yes, and in air conditioning mode, not in heat mode. And then turn the unit off once all the refrigerant is back in the outdoor unit.
@chadbrooks9029
@chadbrooks9029 Ай бұрын
@@airspool mine is a inverter style. Will I have any problem getting all the Freon out? I know it’s got protection built in in the event that Freon gets low and shuts off the compressor.
@afiqafiq4016
@afiqafiq4016 2 ай бұрын
why mine dun have that screw
@airspool
@airspool 2 ай бұрын
Your actual results may vary.
@lincolncarr104
@lincolncarr104 2 ай бұрын
ok so on centrel air i push the start silinoid from out side then let go whrn done how do i kick the compressor on and of from outside a mini split....
@airspool
@airspool Ай бұрын
Yes, just turn the unit on and when the refrigerants in the outdoor unit, cut the power to the outside unit.
@MikeStrine_RoatanStrineWay
@MikeStrine_RoatanStrineWay 2 ай бұрын
For 2024: Would using a standalone 48V Power Sation as the 'plug-in' 120V for the unit, work for evening runtime? Instead of connecting to our home 120V system @ .40/kWh. If I built a portable power station or even an outdoor weather-resistant unit, I could add a few more panels to charge the power station up during the day.
@airspool
@airspool 2 ай бұрын
Yes, sure. The system won't know the difference. And the system will take any alternating current, weather from an inverter or from the grid, as long as it's between 110 volts and 240 volts. So it's pretty flexible on what you feed it.
@ajarivas72
@ajarivas72 Ай бұрын
​@@airspool I don't get it. Can you feed the hybrid unit with AC or DC current? Does one need a rectifier to use the AC current?
@carsteng6951
@carsteng6951 2 ай бұрын
Do all mini splits allow for the solar direct hook up?
@airspool
@airspool 2 ай бұрын
No, very few do. But that's now. A few years from now, we think many will, since the cost of solar panels is approaching zero, almost literally. By 2025, the cost per what is forecasted to be 10 cents wholesale price. Right now, it's pretty easy to find solar panels for 25 cents or what, meaning that you could power or 1 ton of air conditioning for 25 years for around $350. It becomes a no-brainer.
@MikeStrine_RoatanStrineWay
@MikeStrine_RoatanStrineWay 2 ай бұрын
How WIDE is the indoor unit? How far out from the center will the hole be required to go through the wall? Can the unit be installed above a 36" wide exterior door? Missing the Jack Studs and (2"x4") Header?
@airspool
@airspool 2 ай бұрын
Hi Mike, the indoor unit is 33.07 in wide. For some of these specifics, refer to airspool.com/install and check out some of the installation videos for the Airspool unit on KZbin.