Пікірлер
@ahmadhafizrahadiansyah5670
@ahmadhafizrahadiansyah5670 3 сағат бұрын
Hari senin dan wafat dan jenazahnya ditolak oleh orang -untuk berubah menjadi lebih-
@skylermeddtrainvideos
@skylermeddtrainvideos 6 сағат бұрын
What Museum is this and what city and state is it in?????
@annetemple3797
@annetemple3797 7 сағат бұрын
7:27 sounds beutiful
@annetemple3797
@annetemple3797 7 сағат бұрын
11:00 idk
@infunerous666
@infunerous666 Күн бұрын
They timed out, they’ll go down again
@RailroadSignsandSignals
@RailroadSignsandSignals Күн бұрын
Sometimes they will do a cycle of going down and back up but this one was down for about 15 minutes after the storm passed and went back up without reactivating once it was drying up.
@ManuelMartinez-ws4gw
@ManuelMartinez-ws4gw Күн бұрын
Did you call it in?
@RailroadSignsandSignals
@RailroadSignsandSignals Күн бұрын
Yes, not only did I call it in but the gates went up as I was still on hold.
@theeyum2
@theeyum2 Күн бұрын
I wonder what caused it to do.. well... Whatever THAT was.
@RailroadSignsandSignals
@RailroadSignsandSignals Күн бұрын
Bad track ballast condition. It is caused by excessive heat, rain and snow. In this case it was caused by rain and as it started drying up it resolved the problem on its own. Sometimes that doesn’t always work which is why it is still good to call it in if it is causing traffic or on a busy road.
@adyharakanan9305
@adyharakanan9305 2 күн бұрын
Why the gate light dont lit up
@RailroadSignsandSignals
@RailroadSignsandSignals Күн бұрын
That is due to a phenomenon with camera speed and the hertz of AC current with LEDs. They will appear off at times when they are actually on.
@adyharakanan9305
@adyharakanan9305 2 күн бұрын
Hi RS&S im new subscriber i love your videos🎉🎉🎉🎉
@hane_nek
@hane_nek 2 күн бұрын
Ứdds99658
@annetemple3797
@annetemple3797 2 күн бұрын
put high pitch bell
@RailroadSignsandSignals
@RailroadSignsandSignals 2 күн бұрын
?
@daltondick5223
@daltondick5223 2 күн бұрын
Do you change out parts often for variety? I’m genuinely curious and can’t remember if I’ve asked you before.
@RailroadSignsandSignals
@RailroadSignsandSignals 2 күн бұрын
I do not change out components without reason and it is actually the opposite of having variety. At this particular crossing, I upgrade when I find newer parts or matching parts that are currently operating so not only do they all match but they operate better with matching equipment. This crossing is considered as active and used for the purpose of safety unlike the next crossing setup soon to be featured which uses a lot of the old parts that used to operate at this crossing.
@daltondick5223
@daltondick5223 2 күн бұрын
@@RailroadSignsandSignals oooh so the modern stuff is used in the crossing but the other equipment will be like a working display?
@user-ps3xl5si4l
@user-ps3xl5si4l 2 күн бұрын
Waste of time if you also me
@Coldpurplerailfans
@Coldpurplerailfans 3 күн бұрын
Hey RS&S! Thank you for hearting my comment, i really appreciate that. How do you get your crossing equipment? And Where is that train museum Located?
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
I have received my equipment from several places. An NS contractor removing an abandoned railroad got me started and parts from eBay to keep them going.
@ManuelMartinez-ws4gw
@ManuelMartinez-ws4gw 3 күн бұрын
Like a while back, you were working on the project. I was just asking. How’s it going with the old crossings did you had like a long time ago?
@ManuelMartinez-ws4gw
@ManuelMartinez-ws4gw 3 күн бұрын
And also, I don’t know if anyone has said this, but did people ask where you get the equipment?
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
We just set up the first signal and cabinet at that railroad museum. All is going well there so it shouldn’t be long before it is operational.
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
I got a majority of my equipment from an NS contractor that was demolishing an abandoned railroad and were going to scrap the signals. Offered them a bit more than what they would have gotten by scrapping them. I have also received some signals from Union Pacific and parts on eBay.
@ManuelMartinez-ws4gw
@ManuelMartinez-ws4gw 3 күн бұрын
@@RailroadSignsandSignals I have one question at the end of the video in the background, I think they were three crossings do those work or they just there
@ManuelMartinez-ws4gw
@ManuelMartinez-ws4gw 3 күн бұрын
Nice
@dancline2143
@dancline2143 3 күн бұрын
How many hours a week do you volunteer, here, working on crossing equipment?
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
That differs from a few hours to a whole weekend depending on the work being done. I have worked two straight days before (nearly 37 straight hours) on this particular setup when the relay system had to have all the wire replaced and was still having issues that had to be found and fixed. This is not the only museum I have signals at now too so I have had to learn to start working faster and more efficiently to compensate. It also helps that I have someone who regularly assists me in maintaining the signaling equipment.
@LeeAlan-uj5mz
@LeeAlan-uj5mz 4 күн бұрын
I do know for you
@Isaactheviolinist
@Isaactheviolinist 4 күн бұрын
Two questions one the train in front of the pedestrian signal that got the extended gate is that going to go in service or no
@Isaactheviolinist
@Isaactheviolinist 4 күн бұрын
two why does the bells on ring as soon as the gates rise
@TrainKid2024
@TrainKid2024 4 күн бұрын
@@Isaactheviolinist I belive that as the gate move it makes contact with brushes or something that controls the bells.
@PascoRailProductions-2024
@PascoRailProductions-2024 3 күн бұрын
Contact 4 in the gate mech I think
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
No, that track is not used which is why the gate was allowed to be extended to go over the rails. The reason the gate was extended was to not only prevent people from going around the gate by walking on the rails but it improved the operation of the S-20 gate mechanism by doing so. The bell ringing when the gates go back up is due to the bell sequence and it was chosen to alert pedestrians when the gates activate and when they go back up. When they are in the down position they can stay there for a long period of time so it wasn’t a good idea to leave the bells ringing in the down position.
@Isaactheviolinist
@Isaactheviolinist 2 күн бұрын
​@@RailroadSignsandSignals ah ok cool thanks man
@rodgodx345
@rodgodx345 4 күн бұрын
Wait a sec ur not using the remote control for the crossing anymore?!
@wildtraingamer3146
@wildtraingamer3146 4 күн бұрын
They haven’t been for a while
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
We were using the gold test nut in the bungalow.
@romania_railroad_crossings
@romania_railroad_crossings 4 күн бұрын
nooooo i liked the mini one
@100killstreakOg
@100killstreakOg 4 күн бұрын
Does the white train go on tracks too or no?
@Redcatplayz1255
@Redcatplayz1255 4 күн бұрын
No
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
Unfortunately no.
@MSCM2000
@MSCM2000 4 күн бұрын
Great job
@BBFHD721
@BBFHD721 4 күн бұрын
How did you do that? Thats impressive man!
@LiliaPierre
@LiliaPierre 4 күн бұрын
Nice👍👍👍
@t.c.bowling1934
@t.c.bowling1934 4 күн бұрын
Can you show a wiring diagram to make a gate crossing work. Nobody can seem to explain it.
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
I cannot show complete schematics as they are classified material.
@t.c.bowling1934
@t.c.bowling1934 Күн бұрын
I put up a safetran and griswold crossing gates and there are no schematics. ​@RailroadSignsandSignals
@LeeAlan-uj5mz
@LeeAlan-uj5mz 5 күн бұрын
Why are you like the thing is moving
@davizinbr12345
@davizinbr12345 7 күн бұрын
Nice vídeo
@louisyang7976
@louisyang7976 9 күн бұрын
why this railroad crossing has a e bell and
@user-ps3xl5si4l
@user-ps3xl5si4l 9 күн бұрын
Why is it so long
@ManuelMartinez-ws4gw
@ManuelMartinez-ws4gw 10 күн бұрын
Cool E-bell
@RailroadSignsandSignals
@RailroadSignsandSignals 10 күн бұрын
I finally decided to give KZbin Shorts a try. I plan on posting frequently to KZbin Shorts. I decided to record the malfunction while I was getting the replacement hold clear device needed to fix this issue.
@maiseethao6722
@maiseethao6722 8 күн бұрын
❤🎉
@DannyWLuna29TV
@DannyWLuna29TV 12 күн бұрын
Is the gate stuck?
@adensrailfanningproductions
@adensrailfanningproductions 10 күн бұрын
A coil burnt out on the gate mechanism. So no its not stuck
@Mr-blue584
@Mr-blue584 12 күн бұрын
1 milloin views
@infunerous666
@infunerous666 13 күн бұрын
Check your RX relay B12 and N12 terminals to the power supply check both leads make sure you’re not losing your battery or negative, you can have a bad connection or ground. Also check the voltage to those lights they must be set to 9v
@Adelaidehilltrainspotter
@Adelaidehilltrainspotter 13 күн бұрын
How come there’s always a malfunction with crossings
@MSCM2000
@MSCM2000 12 күн бұрын
Becuase just like with anything else the parts are bound to go bad sooner or later just like a car.
@Adelaidehilltrainspotter
@Adelaidehilltrainspotter 12 күн бұрын
@@MSCM2000 oh
@Adelaidehilltrainspotter
@Adelaidehilltrainspotter 12 күн бұрын
Safetran is bad because alot of there stuff just stops working over 7 years
@FouadKhiyat
@FouadKhiyat 9 күн бұрын
Most of manufacturers they have things going bad so they can continue selling that's how everything goes in our world unfortunately.
@JadenLamb
@JadenLamb 13 күн бұрын
And I just noticed one of the main crossing lights when that gate had the hold clear device fail that main light was about to fall off
@JadenLamb
@JadenLamb 13 күн бұрын
Just a perfect time for me to comment on this my buddy who films The Murder Mystery Dinner Train in Fort Myers he noticed one of the new railroad crossing County over gates going down so fast and I noticed it too but what could have caused the new railroad crossing cantilever gate to drop down fast
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
Bad limiting resistor or a gate that wasn’t counterweighted properly would cause a fast dropping gate.
@finnythao1548
@finnythao1548 13 күн бұрын
Those who are here under an hour
@rodgodx345
@rodgodx345 13 күн бұрын
is the crossing still and always still be remote activated? also nice job on the crossing fixing it!
@Isaactheviolinist
@Isaactheviolinist 13 күн бұрын
Wow a video from you at 7 in the morning never seen anything like this before you would always post in the afternoon or evening
@Isaactheviolinist
@Isaactheviolinist 13 күн бұрын
And wow I heard that train from the distance if you guys are near a railroad track or that is just the interstate and planes
@Indianarailproductions
@Indianarailproductions 13 күн бұрын
@@Isaactheviolinistthere’s a active mainline in the background, a train is seen in. One of his videos
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
I post when I have the ability to. I don’t have a regular posting schedule but I do try to post on the weekend.
@user-ns9cj9lv1o
@user-ns9cj9lv1o 15 күн бұрын
。_
@Trainplaneenjoyer
@Trainplaneenjoyer 16 күн бұрын
What happened to the mech bells🥺
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
Getting phased out.
@josephwallace7287
@josephwallace7287 16 күн бұрын
I miss electromechanical bells.😢
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
Won’t be seeing them for much longer on my signals. Eventually they will be phased out when I get enough replacement bells.
@-northeastohiosirensandtra5641
@-northeastohiosirensandtra5641 18 күн бұрын
Nice Video, Nice setup! Hey, I have a question, what are the dimensions of those gate arms? As in if you measure the width and thickness of the aluminum box tubing that is the gate arm, how wide and tall is it? To slide over the adapter.
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
5 inches tall by 2 inches wide and I believe 1/8 of an inch thick and usually 16 feet long. 4 inch tall gate tape for the base segment with the stripes being 16 inches long per stripe, slanted or straight striping.
@-northeastohiosirensandtra5641
@-northeastohiosirensandtra5641 3 күн бұрын
@@RailroadSignsandSignals Thank you
@wearethekbproductions
@wearethekbproductions 18 күн бұрын
Awesome man! I still need to give you my GS E Bell to fix when I get back home to Texas. Currently in Birmingham, AL for conductor school. Pray for as this is my last week and all my final exams start tomorrow
@RailroadSignsandSignals
@RailroadSignsandSignals 3 күн бұрын
Definitely looking forward to fixing them, glad to hear you passed your exams!
@rodgodx345
@rodgodx345 18 күн бұрын
I don’t hear the remote click to activate the crossing?
@BBFHD721
@BBFHD721 18 күн бұрын
Nice work!
@chamberlainman1012
@chamberlainman1012 18 күн бұрын
Great video
@SamuelElevatorFan
@SamuelElevatorFan 18 күн бұрын
the older reco gate lights be replaced as neg leds gate lights
@slawekm6054
@slawekm6054 19 күн бұрын
That was a weird level crossing at the start like it will be funny if you were in your car and saw that thing like that😮