@ericjohnson9080
@ericjohnson9080 3 күн бұрын
Do these blow air 4 way?
@ericdebbold5771
@ericdebbold5771 4 күн бұрын
Could you have run a branch box in the attic to avoid running 3 line set runs down the garage wall and out of the house?
@rigobertolopez6868
@rigobertolopez6868 5 күн бұрын
Big guy is strong!
@ductlessplushvac
@ductlessplushvac 5 күн бұрын
Yes he is lol! Thank for watching
@heronheron7432
@heronheron7432 6 күн бұрын
is 7.2 ounces short on refrigerant enough to cause the FS head units to run for several hours and then all stop operating and flash single green light until powering each FS unit off and then back on? Once power cycled they run again for several hours before doing the same thing. The system is an MXZ 48k Hyperheat, 5 port PAC Branch Box, 2- FS15's, 1- FS12, 2 FS06's, 209.2' total pipe length. DSB called for 8.69 LB of additional refrigerant, only 8.24 went in (7.2 ounces short)
@ductlessplushvac
@ductlessplushvac 6 күн бұрын
If you’re short you need to add it in.
@heronheron7432
@heronheron7432 6 күн бұрын
@@ductlessplushvac Thank you for your quick response! I agree with that and as soon as I get to the shop and grab another tank I will go back and top it off- I was just trying to determine if that amount of shortage would be sufficient to cause that behavior or should I be looking at something else?
@ductlessplushvac
@ductlessplushvac 6 күн бұрын
@@heronheron7432 double check everything
@heronheron7432
@heronheron7432 5 күн бұрын
@@ductlessplushvac Added the 7.2 ounces of refrigerant to the capacity required according to DSB. I remeasured all of the line set runs to make sure what was entered into DSB was correct, and it was. I double checked all of the wiring from the branch box to the head units to make sure that terminals are matched at both locations, and did this for the comm cable to the condenser, with the 16 shielded cable being grounded at only one end. The condenser, and the branch box are powered separately and are each receiving 247V's. All head units are powered on and run for several hours then stop running and blink green. Anything else I should be looking at?
@heronheron7432
@heronheron7432 4 күн бұрын
@@ductlessplushvac I disconnected each head one at a time until the symptom stopped. Ran a new cable to the problem unit from the branch box, problem went away reconnected the old cable it immediately returned. Chased down and physically viewed all of the first cable to find the electricians had popped a staple through it while running a bathroom light\fan circuit.
@jonathanlackman7198
@jonathanlackman7198 12 күн бұрын
Jared, can you have a mini split that has one compressor outside that feeds two separate casettes? I think the answer is yes.
@ductlessplushvac
@ductlessplushvac 6 күн бұрын
Yes you can
@Syntheticoilhq
@Syntheticoilhq 6 күн бұрын
@@ductlessplushvac thanks!
@brianb9410
@brianb9410 17 күн бұрын
Very helpful, thank you. What did the home owner say about opening the closet door? Ha!
@ductlessplushvac
@ductlessplushvac 6 күн бұрын
Not much lol
@saveriotranquilli929
@saveriotranquilli929 18 күн бұрын
Great job, man! And many thanks for explaining everything! What about the other switches on the main board, like SW4 or SW5? Do they need to be in the off position? Also, do you have a video showing how to recharge the additional refrigerant in the system? Thank you!
@ductlessplushvac
@ductlessplushvac 5 күн бұрын
Not yet but we will make one for you.
@michelegallo1
@michelegallo1 20 күн бұрын
Great video, we are just installing one of these intelliheat now for a client, did you have that 2nd follow up video on the controller thermostat setup, I didn't seem to see it. Looking forward to another great video.
@canadian_steve1844
@canadian_steve1844 21 күн бұрын
Hey is there a thermostat built in to the unit or the remote or do I have to install a thermostat on the wall
@bittondb
@bittondb 27 күн бұрын
do you have an example video for a concealed unit. i want to replace one furnace and replace it with 5 concealed units on existing duct work. thanks.
@ductlessplushvac
@ductlessplushvac 27 күн бұрын
We do on a video
@bittondb
@bittondb 26 күн бұрын
@@ductlessplushvac great. which one? Can you help w/ sizing?
@adrianbradshaw4956
@adrianbradshaw4956 28 күн бұрын
It’s insane… anything related to a home “professionals” are licking their chops ready to mark up a good or service 300%. I learn to do everything myself (minus electrical) or it just doesn’t get done.
@ductlessplushvac
@ductlessplushvac 27 күн бұрын
You can't do electrical? Why it's the easiest thing to learn. And your 300% is BS! That's not true whatsoever!
@michelegallo1
@michelegallo1 29 күн бұрын
great video's which is the video link you mention that you prepped the install before with line-set and such, i cant seem to find it looking through videos
@jedeckert9525
@jedeckert9525 Ай бұрын
I have a York. I can set it at 60 and it will get down to 60.
@ductlessplushvac
@ductlessplushvac Ай бұрын
Well how hot is it outside when you run it down to 60? 100, 95, 85……? You must have an outrageous utility bill! Congratulations 🎉
@jessecarrillo8587
@jessecarrillo8587 Ай бұрын
How will you hook up all 3 drains?
@ductlessplushvac
@ductlessplushvac Ай бұрын
We run them from the indoor heads drain line with 3/4” PVC and run the pipes outside side with the main refrigerant lines.
@RKnowles
@RKnowles Ай бұрын
What do you do when you have a bedroom and a small bathroom off the bedroom? Does the small bathroom need its own unit?
@ductlessplushvac
@ductlessplushvac Ай бұрын
You will not need one in the bathroom just leave the door open and the bathroom will be completely warm or conditioned
@RKnowles
@RKnowles Ай бұрын
@@ductlessplushvac Does that mean if you're in the bathroom for a while during the cold winter days or hot summer days that you'll be uncomfortable or the residual will be enough?
@TheSoaringChannel
@TheSoaringChannel Ай бұрын
I didn't see anywhere how the device is mounted inside the ceiling.
@ductlessplushvac
@ductlessplushvac Ай бұрын
It's on the video watch closer next time. Thanks for watching.
@TheSoaringChannel
@TheSoaringChannel Ай бұрын
@@ductlessplushvac you didn't show it. Just your hand being stuffed in there lol
@ductlessplushvac
@ductlessplushvac Ай бұрын
@@TheSoaringChannel we have other videos that show it then
@chetmyers7041
@chetmyers7041 Ай бұрын
15:30 Yellow Jacket could send you another bending tool, so you don't have to reconfigure from FRONT to BACK bend modes. Just have one set to each mode. "Hey Jimmy, throw me a pair of left-handed tin snips." "No, those are the right-handed, the other one."
@chetmyers7041
@chetmyers7041 Ай бұрын
11:06 How high is that ceiling? You say that filter needs to be cleaned monthly? What would be the cost for a service call to clean all four interior units in this house? How does one access the staircase hidden unit for cleaning? ie: what type of ladder/scaffold?
@ductlessplushvac
@ductlessplushvac Ай бұрын
Most of the time the owners do the service. But cleaning the units each month would be a service call and we would do it by the hour.
@jaggeranand6408
@jaggeranand6408 Ай бұрын
Really...
@ductlessplushvac
@ductlessplushvac Ай бұрын
Really?
@tbc_2024
@tbc_2024 Ай бұрын
Great install video. Could this ceiling unit be mounted vertically in a wall between joists with drain hole at the bottom? I have extra room on the backside.
@ductlessplushvac
@ductlessplushvac Ай бұрын
No they must be level and flat
@JollyDeacs11
@JollyDeacs11 Ай бұрын
I love your video, where did you route the condensate line?
@ductlessplushvac
@ductlessplushvac Ай бұрын
Outside with the lines
@TheOxman420
@TheOxman420 Ай бұрын
You should use a CRT and a half inch hose. Connect your micron gage to the CRT and your pump. Your creating a ton of extra time using all them gages and long hose that's smaller in diameter. Shouldn't be using anything smaller then 1/2 when evacuating.
@ductlessplushvac
@ductlessplushvac Ай бұрын
Bro this line set is super short.
@GregTellner
@GregTellner Ай бұрын
Do they make a wired thermostat that can be used with the wifi app?
@ductlessplushvac
@ductlessplushvac Ай бұрын
Yes
@ductlessplushvac
@ductlessplushvac Ай бұрын
Yes
@Ryan-RM
@Ryan-RM Ай бұрын
Hi, do you all install or recommend installing phase/voltage monitors with these types of systems in addition to surge protectors? I didn’t notice that you had any surge protection on this job unless they have a whole home surge protector. Great information on this video.
@ductlessplushvac
@ductlessplushvac Ай бұрын
Obviously it wouldn't hurt some people buy them some don't.
@englishmaninco8711
@englishmaninco8711 2 ай бұрын
where is part 2? cannot find it
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
Still waiting for the house to get finished built
@FernandoGarcia-bk1jl
@FernandoGarcia-bk1jl 2 ай бұрын
So you made this video to show your equipment or just to hate on others? You sound so cheap hating on others I would never watch your videos again
@VapersRecruit
@VapersRecruit 2 ай бұрын
I have the SVZ-KP30NA indoor air handler ducted system. High humidity levels right now and it seems like there is a drying mode I keep hearing about, but can’t set my MHK2 to dry. Do you have any info on this? Thanks!
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
You might have the dry mode turned off in the backend settings. You need to check to see if it was turned off in the setup.
@tinamagnuson2
@tinamagnuson2 2 ай бұрын
What depth do you need to install in the ceiling? I have a two story balloon framed 105 year old cottage with plaster ceilings. The upstairs is easy, but getting lines to the first floor is tougher. I don’t want inside wall units.
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
10” is perfect
@dominiquebrown2890
@dominiquebrown2890 2 ай бұрын
Can you make a full video on installing a ceiling casset with no attic access
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
We can thanks for watching
@jonstebbins5115
@jonstebbins5115 2 ай бұрын
Do you know if they offer some sort of better filter for those ceil units?
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
I haven't seen one
@parseval6162
@parseval6162 2 ай бұрын
Who can explain how to connect new indoor units with wifi built-in to a router?
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
You use the kumo app
@b.buster.
@b.buster. 2 ай бұрын
Do all the ceiling cassettes the same dimensions? Are there any that fit 16" on center joists?
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
They all fit 16” center only the one-way ceiling units, not the square ones.
@jeffm9606
@jeffm9606 2 ай бұрын
Awesome video, thank you so much
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
I liked that one myself! Thank you for watching the video.
@ShugarMeat
@ShugarMeat 2 ай бұрын
I wish you would have gone over the condensate removal system with these unit. I’m staring at one with a 3/8 rubber tube for a drain 😒
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
Thanks for watching the video
@markkulyas2418
@markkulyas2418 2 ай бұрын
If you can afford $500 a month electric bills air conditioning is the way to go. Swamp coolers are way less expensive to run but yeah you're right they are a headache.
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
Thanks for watching. Jared
@alexinaustralia
@alexinaustralia 2 ай бұрын
Lol the guy promots mitshubishi of course MRCOOl is shit lmao
@mikemiller9030
@mikemiller9030 2 ай бұрын
Mitsubishi 5 branch box here. Probably best to use 12 awg vs 14 for the power into the branch? Still needs a signal wire set between the "m" terminals? Im not an electrician but am mostly calable Lol. If you have time for an answer i would be most humbled
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
I'm not sure what your asking. The M1,M2 terminals must be landed @ the BB
@mikemiller9030
@mikemiller9030 2 ай бұрын
@@ductlessplushvacsorry. My outdoor compressor will send line voltage to the 5-branch box. Might it be ok to use 12 awg stranded vs 14 awg solid for that, or is solid wire the usual choice? Aside from all this, will still need the m-terminals wired between the outdoor compressor and bb?
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
@@mikemiller9030 just do what the instructions say and you will be perfect
@1Keymaker
@1Keymaker 2 ай бұрын
I contacted a HVAC company to trim the lines on a MR cool 4 zone unit that came with our new house. The lines where all coiled up and they refused to do it. They said leave it alone those units are designed to work that way. Knock on wood but unit works flawlessly.
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
Well I hope they work for you for a long time.
@vze25v9v
@vze25v9v 2 ай бұрын
By the way, you are spot on about these young guys who don't want to work and won't take responsibility.
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
Thanks
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
Thanks
@vze25v9v
@vze25v9v 2 ай бұрын
Great video. You guys are the best. Regarding the line set, is there a specific manufacture you recommend?
@ductlessplushvac
@ductlessplushvac 2 ай бұрын
They come from mueller
@epstv7254
@epstv7254 3 ай бұрын
Next part please
@eloperadorbravo3421
@eloperadorbravo3421 3 ай бұрын
What dose something like this cost ?
@ductlessplushvac
@ductlessplushvac 3 ай бұрын
It depends $18-$25k
@fiehlsport
@fiehlsport 3 ай бұрын
I find it really odd that it’s not considered permissible to run over the total BTUs of the outdoor unit. The indoor units should never all be running at 100% output, unless you’re turning the system on for the very first time in a hot or cold house. I like to size the outdoor unit one step below what the indoor unit totals are to allow for an even smaller minimum output on the condenser, so my 6k and 9k indoor heads have a chance of actually modulating down. Greater modulation to the 1000-3000BTU range is so much more comfortable than a 6k bedroom unit cycling at 5 or 6000BTU all day and night. Maintaining room temp shouldn’t need 80-100% of a head’s output
@ductlessplushvac
@ductlessplushvac 3 ай бұрын
All VRF units work like that. They never will ramp up to 100% capacity unless the load requires it. The altitude capacity changes in Colorado in the Denver area it's about 17-20% on average depending on elevation right out of the box so a 9k is more like a 6500k a 6k is more like a 4500k That's why you don't want to oversize the (2) indoor and outdoor units due to the De-rating drop.
@fiehlsport
@fiehlsport 3 ай бұрын
@@ductlessplushvac great point about the altitude. Gotcha!
@stevendennis7933
@stevendennis7933 4 ай бұрын
Awesome work! Ive seen your bridge system for ceiling cassette with attic access. How did you support the 2x4 in this application? Do you have different methods of mounting for installs like this one with no attic access? Thanks.
@ductlessplushvac
@ductlessplushvac 4 ай бұрын
All we did was put some 2x4”s up in the ceiling and installed the drops of all thread.
@stevendennis7933
@stevendennis7933 4 ай бұрын
@@ductlessplushvac Thanks. The channel is amazing.
@Art-si7cj
@Art-si7cj 4 ай бұрын
How do you mount cassettes in the ceiling when there is a floor above it?
@ductlessplushvac
@ductlessplushvac 4 ай бұрын
As long as the joist is taller than 8” it's 100% doable.
@Art-si7cj
@Art-si7cj 4 ай бұрын
Clean work! How often do those drain pans need to be cleaned in the ceiling cassettes? Also, is there a fail-safe to disable the unit when a condensate pump fails?
@ductlessplushvac
@ductlessplushvac 4 ай бұрын
If you take great care of the filters and clean them every month you should be ok with the drain pans. If you want to take extra care of the system you can flush them out however they are glued down. The units have a float switch if the pump fails it will not operate.
@Art-si7cj
@Art-si7cj 4 ай бұрын
How do you air seal around the ceiling cassette in the attic?
@ductlessplushvac
@ductlessplushvac 4 ай бұрын
I get this question a lot. There is no air communication from the attic and the indoor air. Once the grill is installed we seal the edge of the grill with caulking.
@Art-si7cj
@Art-si7cj 4 ай бұрын
do you do anything air sealing from the top later?
@ductlessplushvac
@ductlessplushvac 4 ай бұрын
You seal the grill from below.
@jasonrodog9827
@jasonrodog9827 4 ай бұрын
What do you charge for installation?
@ductlessplushvac
@ductlessplushvac 4 ай бұрын
They depend on difficulty sizes am out of unit. We need to do an estimate
@runfayalife
@runfayalife 4 ай бұрын
Went from Florida to Albuquerque and experienced swamp coolers for the first time. They're awful. Mini splits are outstanding and efficient enough to run on solar power.
@ductlessplushvac
@ductlessplushvac 4 ай бұрын
We agree 1000% Thanks for watching. Jared